• Title/Summary/Keyword: Temporary Facilities

Search Result 162, Processing Time 0.028 seconds

A study on the outlier data estimation method for anomaly detection of photovoltaic system (태양광 발전 이상감지를 위한 아웃라이어 추정 방법에 대한 연구)

  • Seo, Jong Kwan;Lee, Tae Il;Lee, Whee Sung;Park, Jeom Bae
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.403-408
    • /
    • 2020
  • Photovoltaic (PV) has both intermittent and uncertainty in nature, so it is difficult to accurately predict. Thus anomaly detection technology is important to diagnose real time PV generation. This paper identifies a correlation between various parameters and classifies the PV data applying k-nearest neighbor and dynamic time warpping. Results for the two classifications showed that an outlier detection by a fault of some facilities, and a temporary power loss by partial shading and overall shading occurring during the short period. Based on 100kW plant data, machine learning analysis and test results verified actual outliers and candidates of outlier.

Residents' Perception on Living Environment in Metropolitan Area - The Case of Daegu Metropolitan City - (대도시 서민 주거지 환경실태와 주민의식 - 대구시 일부 지역을 대상으로 -)

  • Kim, Han-Su;Jang, Mong-Hyun
    • Journal of the Korean housing association
    • /
    • v.22 no.4
    • /
    • pp.113-120
    • /
    • 2011
  • The primary purpose of this study is to suggest policy directions for redevelopment project based on analysis of residents' perception on needs and reasons of redevelopment, and development type in old settlements in Daegu Metropolitan City. The main findings are follows. First, the study area is short of public space such as road and parks, occupied by old single detached houses with small parcel. The living environment of the area consist with many 20 years or older two story houses is very poor. Second, most of residents (58.5%) consider economic factors or cheaper rent more serious than other factors such as convenience, amenity, and education facilities. Third, residents want new housing construction even though explanatory power of trash collection, bad smells, privacy is very high in residents' satisfaction. Fourth, most of residents (88.8%) agree redevelopment and show strong preference to high-density apartment construction through demolish-and-development type of redevelopment approach. They are willing to agree the parcellevel redevelopment if governments provides economic supports and temporary settlements. This finding suggests very important policy implications for current government efforts to improve living environment.

Risk Level Analysis of Architectural Work using AHP (AHP를 이용한 건축건설공사 공종별 위험도 분석)

  • Kim, Jeongmin;Lee, Jong-Bin;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.96-102
    • /
    • 2017
  • The highest fatal accident ratio was recorded in the construction industry. According to the industrial insurance premium rate & business type example, among the construction industry, the architectural work has the highest fatal and loss time accident ratio. Previous literature has investigated various aspects of accident occurrence and prevention in architectural work. However, those studied were limited in that they only focused on the fatal accident without considering the loss time accident. But non fatal accidents were recorded more than 50 times of fatal accidents. Therefore non fatal accidents must be controlled to lessen industrial accidents. Based on this, the goal of this study was to investigate the nature of the loss time accident and derive the risk index of work type in architectural work. In this study, opinions of safety experts were gathered and the risk index of work type was derived using AHP(Analytic Hierarchy Process). And verification was accomplished by comparing the results of this study with the risk index derived by analysis of accident records. Results showed that the risk index of work type was significantly higher in steel frame work, temporary installation work, earth & foundation work, facilities work, concrete work. And statistical analysis for verification showed that coefficient of Pearson correlation was 0.686 and P-value was 0.001.

A Study on the Fundamental Performance of a Lego Block System for Road Recovery (도로복구를 위한 레고식 차도블록 시스템의 기초성능에 관한 연구)

  • Lim, Sunwoo
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.191-198
    • /
    • 2017
  • Lego block system forms a temporary pavement area using the assembled structure block in the road excavation work for the maintenance and installation of facilities. This system was developed for a safe passage of vehicles and pedestrians. A study on the fundamental performance of a lego block system was performed through material quality, sliding resistance and compression tests. And compaction performance of ground on the road was reviewed and evaluated through field tests. As a result, a lego block system for road recovery showed the excellent performance and compaction effect.

A Study on the Improvement Method of Forest Fire Caused by Waste Incineration at the Farming Residential Area (농촌 주거지역 쓰레기소각으로 인한 산불화재 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years' average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.

Risk Factor Selaction and Safety Management Plan in the Underground Excavation Construction (지반굴착공사에서의 위험요인 선정과 안전관리방안 연구)

  • Won, Yu-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.31-37
    • /
    • 2019
  • When the foundation work of the underground part of the building structure or the excavation work of the civil engineering structure is carried out, there is the earthwork work by the inevitable process. As the economic situation continues to develop, construction in urban areas is becoming bigger and higher in scale due to the expansion of infrastructure and the rescue of urban dwellings in urban areas, and excavation of underground roads is inevitable. Excavation of the underground part may cause problems in the process difficulty and safety of the earthworks due to the complexity and various characteristics of the ground selected without consideration of the ground characteristics and site conditions. In order to complete the required facilities, it is necessary to secure the design and construction of the retaining walls. In order to complete the required construction, It is an important factor satisfying construction period and economical efficiency.

The Business Activities in Ui-jeon and their Effects on Commercial Power in the 18th-19th Centuries (18~19세기 의전(衣廛)의 영업 활동과 상권 변동)

  • Lee, Joo-Young
    • Journal of the Korean Society of Costume
    • /
    • v.59 no.8
    • /
    • pp.37-48
    • /
    • 2009
  • This paper summarized the forming, structure and management of the Ui-Jeon(衣廛) in Joseon Dynasty, considered the change of the commercial power of the Ui-Jeon in the $18{\sim}19th$ centuries. The Ui-Jeon was established the early period of the Joseon Dynasty. The Ui-Jeon merchants organized the association named Dojung(都中) and were in business with facilities like Haenrang(行廊) and Doga(都家). The Ui-Jeon was mid-sized Si-Jeon, the licensed shop(市廛). The Ui-Jeon held the monopoly of clothes. The Ui-Jeon merchants sold and bought old clothes, sold new clothes, lent the wedding dress for a bridegroom. The Ui-Jeon paid taxes and supplied clothes, goods and sewing labor for the marriage, funeral ceremonies of the royal family. The commercial power of the Ui-Jeon was threatened by free merchants(私商) named old clothes mercants(破衣商). Finally the Ui-Jeon merchants lost the exclusive right to clothes in 1791. After that, the Ui-Jeon merchanrs appealed to the government to give them the monopoly. The Ui-Jeon merchants regained the sole right to sell Ju-ui(紬衣), one item only, but it was temporary. Separately The Ui-Jeon merchants acquired the rights to collect the sub-taxes(分稅) from free merchants.

Estimation of Electricity Price of the Imported Power via Interstate Electric Power System in North-East Asia (동북아 전력계통 연계를 통한 융통전력 도입 시 가격상한 수준에 대한 분석)

  • Kim, Hong-Heun;Chung, Koo-Hyung;Kim, Bal-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.128-132
    • /
    • 2006
  • Interstate electric power system, as an alternative for energy cooperation under regional economic bloc, has been hotly debated before progressing the restructure in electric power industry and rapidly expanded in many regions after 1990s. Especially, since northeast asia has strong supplementation in resource, load shape, fuel mix etc., electric power system interconnection in this region may bring considerable economic benefits. Moreover, since Korean electric power system has a great difficulty in a geographical condition to interrupt electricity transaction with other countries, it has been expanded as an independent system to supply all demand domestically. As a result, Korean electric power system makes considerable payment for maintaining system security and reliability and expands costly facilities to supply a temporary summer peak demand. Under this inefficiency, if there are electricity transactions with Russia via the North Korea route then economic electric power system operation nay be achieved using seasonal and hourly differences in electricity price and/or load pattern among these countries. In this paper, we estimate price cap of transacted electricity via interstate electric power system in northeast asia. For this study, we perform quantitative economic analysis on various system interconnection scenarios.

The Material Analyses and the Behavior Characteristics according to RCD Discloser (누전차단기 폭로에 따른 동작 특성 및 재료 분석)

  • Han, Woon-Ki;Kim, Hyang-Kon;Gil, Hyung-Jun;Lee, Ki-Hyun;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2019-2021
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCOs are employed at temporary power sites and electrical facilities on the road, they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing Improved models advanced in their performance.

  • PDF

Tsunami Force Acting on Coastal Structures (지진해일에 의해 해안구조물에 작용하는 힘)

  • Hong, Seong-Soo;Ha, Tae-Min;Cho, Yong-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.171-177
    • /
    • 2011
  • Tsunami forces acting on coastal structures have not been relatively much paid attention by researchers. However, they should be appropriately reflected in design of coastal and harbor facilities. The temporary and permanent tsunami shelters have to be chosen to resist stably against unexpected tsunami forces. There have been only few numerical studies on the tsunami forces acting on coastal and harbor structures. In this study, a practical prediction of tsunami forces is carried out by using a two-dimensional numerical model.