• Title/Summary/Keyword: Temperature transmission

Search Result 1,619, Processing Time 0.026 seconds

Winding Temperature Measurement in a 154 kV Transformer Filled with Natural Ester Fluid

  • Kweon, Dongjin;Koo, Kyosun
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.156-162
    • /
    • 2013
  • This paper measures the hot spot temperatures in a single-phase, 154 kV, 15/20 MVA power transformer filled with natural ester fluid using optical fiber sensors and compares them with those calculated by conventional heat run tests. A total of 14 optical fiber sensors were installed on the high-voltage and low-voltage windings to measure the hot spot temperatures. In addition, three thermocouples were installed in the transformer to measure the temperature distribution during the heat run tests. In the low-voltage winding, the hot spot temperature was $108.4^{\circ}C$, calculated by the conventional heat run test. However, the hot spot temperature measured using the optical fiber sensor was $129.4^{\circ}C$ between turns 2 and 3 on the upper side of the low-voltage winding. Therefore, the hot spot temperature of the low-voltage winding measured using the optical fiber sensor was $21.0^{\circ}C$ higher than that calculated by the conventional heat run test.

A Study on Temperature and Tensile Load Analysis of Invar by Flame Exposure on Overhead Transmission Lines (화염노출에 의한 송전선로 인바 강심의 온도 및 인장하중 분석에 관한 연구)

  • Shin, Koo-Yong;Jung, Chae-Kyun;Lee, Sang-Yun;Kang, Ji-Won;Lee, Dong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1895-1901
    • /
    • 2009
  • This paper describes the conductor temperature and tensile load analysis of invar by flame exposure on STACIR(Super Thermal-resistance Aluminium-alloy Conductors Reinforced) overhead transmission line based on real fault phenomena. Firstly, short-circuit fault by flame exposure is analysed by EMTP/ATP simulation, then the cutting causes of Al layer are also discussed. And then, the conductor temperature is calculated based on IEC 60949 according to 3 kinds of materials including invar, Al conductor and ACSR when same load current respectively flows in 3 kinds of material, they are compared each other. Finally, the tensile load tests are performed with various samples including new invar, used invar for a long time and invar exposed flame.

Temperature-dependent Electrical Characteristics of Traveling Wave Electro-absorption Modulator (온도 변화에 따른 진행파 전극형 광 변조기의 전기적 특성 변위에 관한 연구)

  • Rhew, Keun-Ho;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.63-64
    • /
    • 2006
  • Recently, researches for high-speed optical devices have been increased to provide mass data transmission and high-speed optical communication. Optical modulator in the transmission link is one of the crucial devices in total optical network system and it can affect a great effect to the whole transmission properties. In this paper, traveling wave electro-absorption modulator (TWEAM) is examined to ensure high efficiency in the RF range and wide bandwidth. In addition, the temperature-dependence electrical characteristics of TWEAM is investigated. Temperature dependent property variations were characterized using I-V and C-V measurement.

  • PDF

Review of the Conceptual Design for the Use of HTS Power Transmission Cable for a Metropolitan Area

  • Park, Sang-Bong
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.63-69
    • /
    • 2003
  • The necessity of compact high temperature superconducting cables is more keenly felt in densely populated metropolitan areas. Because the compact high-temperature superconducting cables can be installed in ducts and tunnels, thereby reducing construction costs and making the use of underground space more effective, the effect of introducing it to the power system will be huge. Seoul, Korea, is selected as a review model for this paper. The loads are estimated by scenario based on a survey and analysis of 345kV and 154kV power supply networks in this area. Based on this, the following elements for an urban transmission system are examined. (1) A method of constructing a model system to introduce high-temperature superconducting cables to metropolitan areas is presented. (2) A case study is conducted through the analysis of power demand scenarios, and the amount of high-temperature superconducting cable to be introduced by scenario is examined. (3) The economy involved in expanding existing cables and introducing high-temperature superconducting cables(ducts or tunnels) following load increase in urban areas is examined and compared., and standards for current cable ducts are calculated. (4) The voltage level that can be accommodated by existing ducts is examined.

A Study on Heat Transfer of an Underground Power Transmission Cable-Joint (지중송전케이블 접속부에서의 열전달에 관한 연구)

  • Park, M.H.;Kim, J.K.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.265-277
    • /
    • 1993
  • Recently, underground transmission system is growing continuously according to the electric power demand increase in the downtown area. Even if domestic cable makers are manufacturing 154kV oil filled cable and joint, the design technology of cable-joint has not been fully self-reliance. This study is aimed at the detail heat transfer analysis of 154kV cable-joint. So, that is cut into the five sections in order to analyze a conjugate natural convection in two dimensional $r-{\theta}$ coordinate. The streamline and temperature distributions are obtained for each sections. Also the changes of those are analyzed with respect to the variation of transmission currents and cable-joint surface heat transfer coefficients. The same analyses are also shown in view point of the maximum temperature of conductor and local equivalent conductivity.

  • PDF

Power Transmission Mechanism of Electrorheological Clutch Part III: Experimental considerations on performance of ER clutch (전기유변성 클러치의 동력전달 메커니즘 제3보 : ER 클러치 성능에 관한 실험적 고찰)

  • 이규한;심현해;김창호;임윤철
    • Tribology and Lubricants
    • /
    • v.13 no.4
    • /
    • pp.1-9
    • /
    • 1997
  • ER clutch is a device using ER fluid, so called "intelligent material" and is a power transmission system controlled with electric field strength. In this paper(Part III), the behavior of ER clutch under proper conditions was investigated experimentally and compared to theoretical analyses developed from Part I, II. Considering the optimum design concept proposed from Part I, the concentric cylinder type of ER clutch was designed and the experimental apparatus for the performance test was constructed. The comparisons made indicated that the power transmission model of ER clutch and the temperature rise model of ER fluid developed from Part I, II were acceptable for engineering design calculations.culations.

Characteristics of Leakage Current on Transmission Insulators Contaminated Artificially with Soluble and Nonsoluble Materials (용해성물질과 비용해성물질로 인공 오손된 송전용 애자의 누설전류 특성)

  • 최인혁;최장현;이동일;김찬영
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.464-469
    • /
    • 2004
  • The leakage current of transmission insulators contaminated with salt, clay, and kaolin was examined in the Gochang's Long Periods Testing Center. The Insulators were artificially contaminated and estimated with the method of equivalent salt deposit density(ESDD). The artificially contaminated insulators were installed with the same condition as in the real transmission power line and applied with 154 (kV). The leakage current of the artificially contaminated insulators was measured with environment conditions, such as temperature and humidity by the a automatic leakage current detecting system. The leakage current of heavily contaminated insulator was abruptly increased above 72[%] of humidity, even though the leakage current was similar between the contaminated and non-contaminated insulators below 72[%] of humidity. Also, it was found that the humidity was much more important than the temperature in the leakage current of transmission insulators. The leakage current of contaminated insulator was decreased when it was plenty of rainfall, resulting from natural washing.

The Study on Aged Sleeves for Old Transmission Lines (노후 송전선로의 가공송전선 직선 슬리브 분석 연구)

  • Kim, Byung-Geol;Kim, Shang-Shu;Sohn, Hong-Kwan;Park, In-Pyo;Jang, Tae-In;Kim, Jin-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.1009-1014
    • /
    • 2007
  • A detailed study on aged sleeves for old transmission lines was carried out to clarify the deterioration of sleeves and the condition of installation. A lot of removed aged sleeves from transmission lines were investigated. Many biased installed cases and corrosion of steel sleeve part were found. These defects can cause a serious accident such as blackout during operating. The temperature distribution within sleeve of ACSR conductor was precisely measured and examined, conducted as part of series of studies on large currents in transmission lines. According to measurements of the conductor temperature near a joint(sleeve and clamp), the electrical resistance of joint is lower than that of the same length conductor. The detailed results were presented in the text.

Analysis of Transmission Infrared Laser Bonding for Polymer Micro Devices (폴리머 마이크로 장치에 대한 레이저 투과 마이크로 접합)

  • Kim, Joo-Han;Shin, Ki-Hoon
    • Journal of Welding and Joining
    • /
    • v.23 no.5
    • /
    • pp.55-60
    • /
    • 2005
  • A precise bonding technique, transmission laser bonding using energy transfer, for polymer micro devices is presented. The irradiated IR laser beam passes through the transparent part and absorbed on the opaque part. The absorbed energy is converted into heat and bonding takes place. In order to optimize the bonding quality, the temperature profile on the interface must be obtained. Using optical measurements of the both plates, the absorbed energy can be calculated. At the wavelength of 1100nm $87.5\%$ of incident laser energy was used for bonding process from the calculation. A heat transfer model was applied for obtaining the transient temperature profile. It was found that with the power of 29.5 mW, the interface begins to melt and bond each other in 3 sec and it is in a good agreement with experiment results. The transmission IR laser bonding has a potential in the local precise bonding in MEMS or Lab-on-a-chip applications.

Power Loss and Junction Temperature Analysis in the Modular Multilevel Converters for HVDC Transmission Systems

  • Wang, Haitian;Tang, Guangfu;He, Zhiyuan;Cao, Junzheng
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.685-694
    • /
    • 2015
  • The power loss of the controllable switches in modular multilevel converter (MMC) HVDC transmission systems is an important factor, which can determine the design of the operating junction temperatures. Due to the dc current component, the approximate calculation tool provided by the manufacturer of the switches cannot be used for the losses of the switches in the MMC. Based on the enabled probabilities of each SM in an arm, the current analytical models of the switches can be determined. The average and RMS currents can be obtained from the corresponding current analytical model. Then, the conduction losses can be calculated, and the switching losses of the switches can be estimated according to the upper limit of the switching frequency. Finally, the thermal resistance model of the switches can be utilized, and the junction temperatures can be estimated. A comparison between the calculation and PSCAD simulation results shows that the proposed method is effective for estimating the junction temperatures of the switches in the MMC.