• 제목/요약/키워드: Temperature test equipment

검색결과 326건 처리시간 0.034초

철도차량 냉방 및 난방장치의 환경성능 시험방안 연구 (Study on the environmental performance test of cooling and heating equipments' of passenger cabin)

  • 조영민;이준석;박덕신;권순박;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.223-228
    • /
    • 2009
  • Cooling and heating equipments of railroad passenger cabin is one of the most important part in keeping the good thermal comfort of the passengers. The bad performance of these equipments usually results in the comfort of the passengers. However, there is no testing method for cooling and heating equipments during manufacturing the passenger car, and calculation method is frequently used. Many railroad operators spend a lot of money for the maintenance. In this study, a new environmental performance test for railroad passenger cabin was suggested. The temperature of the chamber will be changed from $-40^{\circ}C$ to $60^{\circ}C$. The performance test of cooling and heating equipment in controlling the passenger cabin temperature was carried out under various temperature condition. The testing method to investigate the effect of artificial sunlight irradiation on the passenger cabin temperature was also suggested.

  • PDF

복사열에 노출된 소방용 폼 약제의 열적 특성 연구 (Thermal Characteristics of Fire-Protection Foams Exposed to Radiant Heating)

  • 김홍식;황인주;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1570-1575
    • /
    • 2004
  • In order to evaluate the performance of fire-fighting agents used to protect structures from heat and fire damages, the thermal characteristics of fire-protection foams are experimentally investigated. The current research focuses on the destruction of a fire-fighting foam subjected to heat radiation. A simple repeatable test for fire-protection foams subjected to fire radiation is developed. This test involves foam generation equipment, a fire source for heat generation, repeatable test procedures, and data acquisition techniques. Results of the experimental procedure indicated that each thermocouple within the foam responded in a similar manner and gradually to a temperature of $15^{\circ}C{\sim}20^{\circ}C$. At this point, each trace generally rises to a temperature of approximately $90^{\circ}C$. The temperature gradient in the foam as time passes increases with increased foam expansion ratio. In addition, it is determined that the temperature gradient along the foam for depth decreases with increased foam expansion ratio.

  • PDF

The Method of Determining Stress Levels Regarding the Electrical ALT through Optical Temperature Sensor

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.184-191
    • /
    • 2008
  • Electrical endurance is the critical characteristic of Magnetic contactors(MCs), which are widely used in such power equipment as elevators, cranes, and factory control rooms in order to close and open control circuits. Testing time, however, is not short in typical cases in which some method of reducing the testing period is required. This study shows the method of determining the stress level of electrical ALT(Accelerated Life Test) through optical temperature sensor and the relationship between 0.05 s and 0.1 s for on-time. The tool used for analyzing the test result is MINITAB. I will propose the method of determining the optimized stress level through optical temperature sensor, which will contribute to minimize the testing time and development period and also raise the product reliability.

집단보호장비 내의 회로카드조립체 고장 원인 분석 및 품질 향상 (Analysis of Causes PCB Failure for Collective Protection Equipment and Improvement of Quality)

  • 박세진;기상식
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.87-92
    • /
    • 2019
  • 본 논문은 집단보호장비에 들어가는 회로카드조립체의 고장 원인 분석 및 품질 개선에 관한 연구이다. 해당 장비는 현재 운용중인 무기체계의 구성품으로 냉난방 기능뿐만 아니라, 화생 방어 역할을 한다. 그런데 군에서 운용중에 응축부조립체의 팬이 동작하지 않는 현상이 다수 발생되었다. 이에 따라 고장 원인을 분석하였고 특정 회로카드조립체가 소손됨을 확인하였다. 고온의 환경조건에서 지속적인 냉방가동에 따라 부품이 가열되고 이에 따라 고온에 노출된 전자부품이 열화되어 소손됨을 알 수 있었다. 따라서 본 논문은 이를 해결하기 위해 방열판을 적용하여 과온 동작에 의한 고장빈도를 낮추고 회로카드조립체의 수명을 연장한 품질 개선에 관한 연구이다. 개선된 회로카드조립체는 실험을 통해 방열성능을 확인하였다. 뿐만 아니라 체계 호환성 검사, 양압유지, 소음 시험, 작동시험 등을 통해 성능검사를 마쳤으며 현재 개선된 제품을 적용중이다. 이번 개선을 통해 현재까지 해당 회로카드조립체에서 발생한 고장은 없으며 해당 장비의 품질이 향상됨을 확인하였다.

반도체 검사 장비의 챔버 내부 온도 분포의 균일성 개선 (Improvement of the Uniformity of Temperature Distribution inside Semiconductor Test Equipment Chamber)

  • 이광주;정경석;박성문
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.3626-3632
    • /
    • 2010
  • 반도체 소자 검사장비 핸들러는 주 검사장비인 테스터에 반도체 소자를 개별 또는 그룹으로 이송하여 테스트 환경을 만들어주고 검사가 끝나면 검사결과를 테스터로부터 전송받아 양품과 불량품으로 분류해주는 장비이다. 본 논문에서는 기존에 개발된 핸들러의 챔버 내부 온도 분포의 균일성을 개선하기 위하여, 챔버 덕트의 조절셔터 설치, Heater와 Match Plate 중심위치의 정렬, Match Plate Base의 Hole 크기 및 형상 변경, 온도 센서로 향하는 공기의 흐름이 원활할 수 있도록 핀에 직경 2 mm의 구멍 설치 등의 설계 변경을 하였다. 설계 변경의 효과를 확인하기 위하여, 기존 장비와 설계 개선된 장비 내부의 온도 분포를 32개의 온도 센서를 사용하여 측정하였다. 그 결과 기존 챔버내부 온도 분포는 $87.1{\sim}91.5^{\circ}C$ ($90{\pm}2.9^{\circ}C$)이었으나 개선된 챔버 내부 온도 분포는 $89.5{\sim}90.8^{\circ}C$ ($90{\pm}0.8^{\circ}C$)으로 15분 이상 지속 가능하여 챔버 내부의 온도 분포 균일성이 크게 개선되었음을 알 수 있었다. 또한 설계 변경 이후의 온도 분포는 $90{\pm}1^{\circ}C$의 범위 내에서 10분 이상을 유지하는 목표를 달성하였음을 확인하였다.

극저온에서 풍속의 영향에 따른 발열기자재의 최적설계 (Optimum Design of the Heating Equipment by Influence of Wind Speed at Cryogenic Temperature)

  • 조현준;윤원영
    • 품질경영학회지
    • /
    • 제48권3호
    • /
    • pp.463-479
    • /
    • 2020
  • Purpose: The purpose of this study is to evaluate the performance of heating equipments by implementing the extreme environment in which ships navigating the ice zone are exposed and to study and apply the experimental method to infer the optimized design for each factors. Methods: It is required to verify by analysis and experiment how the environment with low temperature and wind speed implemented through the test facility affects the heating walk-way and The optimum design of the heating walk-way in that extreme environment is derived using the Taguchi technique. Results: The results of this study are as follows; It was found the effect on the condition of each factor and derive optimized conditions that satisfy the performance condition of the heating walk-way in extreme use environment. Conclusion: Ships operating in Polar waters require reliable and durable facilities for all environments during sailing.

액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성 (Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen)

  • 이상화;신우주;;오석호;성재규;이방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

온도.비열 가속모형을 적용한 유압호스조립체 수명특성 연구 (A Study of the Life Characteristic of Hydraulic Hose Assembly by Adopting Temperature-Nonthermal Acceleration Model)

  • 이기천;김형의;조유희;심성보;김재훈
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제11권3호
    • /
    • pp.235-244
    • /
    • 2011
  • Hydraulic hose assemblies deliver a fluid power in various oil pressure equipment such as construction machinery, automobile, aircraft, industrial machinery, machine tools and machinery for ships. Also, they are widely used as pipes in oil pressure circuit. When we estimate their lifetime, it is essential to conduct an accelerated life test by choosing the factor that suits the usage condition of the test object since traditional test method for estimating lifetime under the influence of various external factors incurs hardship in terms of time and expenses. The objective of this study is to propose an acceleration model that takes both temperature and pressure without flexing condition into consideration. The lifetime is estimated by applying the proposed temperature-nonthermal acceleration model to the test data. And we compare the proposed temperature-nonthermal acceleration model and the accelerated life equation suggested by John(1994).

고압전동기 절연진단 결과 추이관리의 문제점 분석 (Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors)

  • 이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

Ni 합금강의 크리프 거동 (Creep Behaviours of 9% Ni Alloy)

  • 황경충;김종배;강성수
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.89-94
    • /
    • 2008
  • 목적: 각종 기계 부품에 주로 사용되는 9% Ni 합금강의 고온 크리프 시험과 그 시편들의 파단면을 관찰하고 Larson-Miller 변수를 적용하여 상수 C값을 결정하여 합금강의 수명을 예측하는데 있다. 방법: 본 시험의 장치는 Andrade와 F. Garofalo 등이 고안한 레버-빔 형으로 제작되었고, 크리프시험 설정조건은 시험편에 미치는 영향을 알아보기 위하여 4가지의 온도조건과 4가지 응력조건을 설정하여 16가지의 조건 하에서 시험을 실시하였다. 결과: 크리프 시험온도가 증가함에 따라 크리프 변형에 따른 응력의 멱지수(n)는 3.97에서 3.55로 점진적으로 감소하는 경향을 보였다. 크리프 변형의 활성화에너지는 응력이 증가함에 따라 90.39에서 83.64 kcal/mol로 점진적으로 감소하였다. Larson-Miller 변수의 계산에 의한 상수 C값은 약 22로 계산되었으며, 사용온도가 제시되면 그 수명을 예측할 수 있다. 파단면의 SEM 측정결과 저온과 고온의 경우는 입내파단에 의한 취성파괴 현상이 나타났으며, 중간정도 온도영역에서는 입계파단에 의한 연성파괴현상이 나타났으며, 일부에서는 딤풀현상도 나타났다. 결론: 9% Ni 합금강에 대한 고온 크리프시험과 그 시편들의 파단면을 관찰한 결과를 제시하여 그 파괴현상을 분석함으로써 설비분야의 부품활용에 대한 기초설계 자료를 구축하여 장비의 수명예측에 유용하게 응용될 수 있다.

  • PDF