• 제목/요약/키워드: Temperature stabilization

검색결과 415건 처리시간 0.023초

영구동토 지대에서 Thermal Siphon의 효율성 연구 (An Study on Efficiency and Application of Thermal Siphon in the Permafrost)

  • 강재모;김학승
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.963-966
    • /
    • 2009
  • A Construction of pipe line foundation and railroad, buildings in a permafrost area requires engineering technology of ground stabilization. In the permafrost area, thermal siphons have been used to stabilize foundation by eliminating the heat of ground to the air. the thermal siphon is a passive heat transfer device that operates by convection through vaporization and condensation. The heat transfer from ground to the air is driven by a temperature difference across the unit. A buried part in ground working as vaporizing function and upper part work as condensing. In this study, buried thermal siphon around the pipe lines laid in the Vladivostok site and measuring temperature variation. It is found that the thermal siphons freezing ground faster and decrease temperature variation in winter season.

  • PDF

콤팩트 형광램프용 전자식 안정기의 주파수 제어에 의한 온도보상 (Compensation of temperature characteristics by frequency control of an electronic ballastfor a compact fluorescent lamp)

  • 송상빈;곽재영;여인선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권1호
    • /
    • pp.27-33
    • /
    • 1999
  • Compact fluorescent lamps are very sensitive to the variation of ambient temperature. This paper investigates the temperature characteristics of a 15[W] compact fluorescent lamp, and compensates the variation of light output by frequency control of its electronic ballast. Circuit parameters for the inverter of the electronic ballast are obtained by analyzing the R-L-C equivalent circuit for the inverter and the lamp. The optimum ratio of the two capacitance($C_1$/$C_2$), which are connected with the lamp in series and in parallel, respectively, is determined which consideration of the temperature variation within a range of 10~35[$^{\circ}C$]. As a result a value of 10 for the ratio is obtained at an operating frequency of 57[kHz], and with this value the frequency control works well for temperature compensation. Its validity is verified by investigating light output stabilization characteristics resulting from frequency control of the lamp at various temperatures.

  • PDF

점토계소지내에서 전기로 더스트 중금속의 소성 온도별 안정화거동 (Stabilization Behavior of Heavy Metals in the EAF Dust-clay Body Mixtures at Various Sintering Conditions)

  • 권용준;김유택;이기강;김영진;강승구;김정환
    • 한국세라믹학회지
    • /
    • 제39권8호
    • /
    • pp.728-734
    • /
    • 2002
  • 전기로 더스트를 점토 또는 백토와 혼합하여 소성온도에 따른 전기로 더스트 내에 존재하는 Cr, Cd, Cu, Pb, Fe, Zn 중금속들의 거동을 조사하였다. 전기로 더스트를 점토와 백토에 각각 0∼50 wt%씩 첨가하였고, 소성은 $200^{\circ}C$ 간격으로 $200∼1200^{\circ}C$ 범위 내에서 수행하였다. 소성된 시편은 TCLP법에 의한 용출실험을 거친 후 ICP-AES로 분석하였다. 중금속표준용액을 이용한 양이온 교환능 실험결과 점토와 백토가 기존의 중금속 흡착제인 제올라이트와 비슷한 중금속 양이온 교환능을 보였으며, Cr에 대해서는 더 우수한 교환능이 관찰되었다. TCLP법에 의한 용출실험 결과 Cr과 Fe는 모든 시편에서 거의 용출되지 않았으며, Cd과 Zn은 소성온도가 증가하고 전기로 더스트의 함량이 적을수록 용출량이 감소하였다. 점토 또는 백토와 전기로 더스트를 혼합 소성 시 일차적으로 양이온 교환능에 의해 중금속이 준안정화되고 이차적으로 공융반응에 의하여 중금속들이 완전하게 고정화되어 중금속 용출을 억제하는 것으로 추정된다. 본 연구에서 백토가 점토 보다는 전기로 더스트 중금속의 안정화에 더 효과적이었다.

개질된 NR/IR 블랜드의 가황 반응에서 나타나는 전기적 특성 안정화의 주파수 의존성 (Frequency Dependency of Electrical Property Stabilization during Vulcanization of Modified NR/IR Blends)

  • 안원술
    • Elastomers and Composites
    • /
    • 제39권3호
    • /
    • pp.179-185
    • /
    • 2004
  • 이소프렌 고무(IR)와 천연고무(NR)가 중량비로 25/75로 혼합된 베이스 고무수지에 카본블랙(CB) 및 가교조제가 섞인 고무복합계의 가황반응 도중의 전기적 성질 변화를 in-situ로 측정하였다. 130, 140, 150, 및 $160^{\circ}C$로 정해진 각각의 가황 반응 온도에서 반응시작 전과 반응도 중의 각각 정해진 시간에서 1Hz에서 10kHz까지의 인가주파수 변화에 따른 체적고유저항 값(P)의 변화를 측정하였다. 가황 반응이 시작되기 전의 초기 P값은 낮은 인가주파수에서는 약 $9.0{\times}10^7\;{\Omega}-cm$의 높은 값으로부터 인가주파수가 높아짐에 따라 급격히 떨어지는 현상을 보이다가 점점 안정화되어 약 $1.0{\times}10^7\;{\Omega}-cm$으로 감쇠되어가는 이중 안정화 패턴의 형태를 보였다. 그러나 초기 P 값의 반응온도에 따른 변화는 온도가 낮아짐에 따라 반응 전보다 반응 후에 1/3 이하로 현저히 낮아지는 현상이 관찰되었고 이와 함께 안정화에 걸리는 주파수 의존도 역시 상대적으로 적어지는 것이 관찰되었다. 관찰된 현상과 해석으로부터 전기적 특성 안정화에 따르는 주파수 의존성은 도체인 전극과 샘플의 계면에서 일어나는 전하의 충-방전 현상과 가황에 따른 샘플 내의 구조변화와 CB의 재배열 등에 의한 전기전도성의 변화로 해석되었다.

가스터어빈형 연속유연소기의 유동에 관한 연구(I) - 연소기의 설계 및 시작 - (A study on Flow Characteristics of Gas Turbine Type Combustor)

  • 이근오;김형섭
    • 한국안전학회지
    • /
    • 제2권3호
    • /
    • pp.37-43
    • /
    • 1987
  • The combustion process in gas turbine combustor mainly influenced by flow pattern in combustor, and especially the flow pattern near the nozzle and the shape of recirculation zone affect strongly on the flame stabilization, temperature distribution and combustion efficiency in combustor. In this paper, the author has designed and manufactured transparent simplified model combustors on the basis of K. Suzuki's combustor design method to investigate the effects of swirl number and secondary air hold arrays in axial position on the flow characteristics by adopting the tuft method and 5 hole pitot tube.

  • PDF

고온 수전해 전해질 막의 열안정화 특성 고찰 (The thermal stabilization characteristics of electrolyte membrane in high temperature electrolysis[HTE])

  • 최호상;손효석;심규성;황갑진
    • 한국수소및신에너지학회논문집
    • /
    • 제16권2호
    • /
    • pp.150-158
    • /
    • 2005
  • Added ratio of 8YSZ powder and organic compounds (solvent, plasticizer, dispersant, binder) properly. It manufactured electrolysis membrane by wet process that make slurry and dry process that do not use organic compounds. In the case of wet process, harmony combination and method of organic compound are an importance element in slurry manufacture. This slurry did calcine at temperature of 140$^{\circ}C$ in Furnace and manufactured electrolyte disk by Dry pressing method. Like this, manufacturing disk sintered at temperature of $1300^{\circ}C,\;1400^{\circ},\;1500^{\circ}C$ in Furnace and completed electrolysis membrane. Confirmed change of crystal structure and decision form through analysis of density, SEM, XRD according to change of sintering temperature, and considered relation with ion conductivity.

Terbium and Tungsten Co-doped Bismuth Oxide Electrolytes for Low Temperature Solid Oxide Fuel Cells

  • Jung, Doh Won;Lee, Kang Taek;Wachsman, Eric D.
    • 한국세라믹학회지
    • /
    • 제51권4호
    • /
    • pp.260-264
    • /
    • 2014
  • We developed a novel double dopant bismuth oxide system with Tb and W. When Tb was doped as a single dopant, a Tb dopant concentration more than 20 mol% was required to stabilize bismuth oxides with a high conductivity cubic structure. High temperature XRD analysis of 25 mol% Tb-doped bismuth oxide (25TSB) confirmed that the cubic structure of 25TSB was retained from room temperature to $700^{\circ}C$ with increase in the lattice parameter. On the other hand, we achieved the stabilization of high temperature cubic phase with a total dopant concentration as low as ~12 mol% with 8 mol% Tb and 4 mol% W double dopants (8T4WSB). Moreover, the measured ionic conductivity of 10T5WSB was much higher than 25TSB, thus demonstrating the feasibility of the double dopant strategy to develop stabilized bismuth oxide systems with higher oxygen ion conductivity for the application of SOFC electrolytes at reduced temperature. In addition, we investigated the long-term stability of TSB and TWSB electrolytes.

극지운항용 빙해선박의 밸러스트 수 결빙방지 기법 연구 (A Study on Anti-Icing Technique for Ballast Water of Icebreaking Vessels Operating in Ice-Covered Water)

  • 정성엽;이춘주;조성락
    • 대한조선학회논문집
    • /
    • 제48권1호
    • /
    • pp.93-97
    • /
    • 2011
  • When freezing is present on ballast water, it can impose additional loads on the hull and effect on stabilization of ship. The anti-icing techniques of ballast water, therefore, are key criteria for ship safety. The existing anti-icing techniques of ballast tank are hull heating, water circulation and air bubble system etc. In this research, anti-icing performance tests for the ballast water using micro-bubble system and sea water circulation system have been carried out at two temperature conditions($-10^{\circ}C$ and $-25^{\circ}C$). Ambient temperature, sea water temperature and temperature of the inner parts of the ballast tank are measured and also ballast water conditions are checked during the model test. The applied anti-icing techniques of ballast water, such as micro-bubble system and sea water circulation system show good performance in the low temperature conditions.

공기주입과 침출수 재순환 방법을 이용한 폐기물 매립지 조기안정화에 관한 현장 실험 연구 (A field study on early stabilization of waste landfill using air injection and leachate recirculation)

  • 윤석표;짜오신;이남훈;전연호;변영덕;안영미;민지홍
    • 유기물자원화
    • /
    • 제18권2호
    • /
    • pp.45-54
    • /
    • 2010
  • 현재 매립 중인 폐기물 매립지 현장에서 공기주입을 5개월간 하였으며, 일정기간 침출수 주입을 병행하면서 이에 따른 매립지 조기안정화 효과를 관찰하였다. 실험부지 면적은 $24{\times}24m$ 규모이었으며, 부지 내에 3~9 m 깊이에 유공부를 설치한 9개의 공기주입용 수직정을 설치하였다. 매립지를 5개월 간 호기적으로 운전함에 따라 매립지 내부 평균 온도는 $70^{\circ}C$까지 상승하였으며, 매립고의 8 %에 해당하는 침하가 발생하였다. 미생물에 의한 유기물 분해촉진을 위하여 1개월간 $94m^3$의 침출수를 실험부지의 일부 구역에 재순환시킨 결과 일시적으로 매립지 내 지하수위가 상승하였고, 혐기성 환경이 조성되었다. 하지만, 침출수 재순환은 침출수 주입정 주변의 매립지 내부 온도를 급속히 상승시키는 효과를 가져왔다. 그러나 과도한 침출수 주입은 매립지 내부를 냉각시켜 온도 상승을 저하시키는 효과를 나타내므로, 매립지 내부온도 변화를 관찰하면서 침출수 주입량을 조절할 필요가 있으며, 침출수 주입은 간헐적으로 하는 것이 바람직하다.