• Title/Summary/Keyword: Temperature of cooler

Search Result 353, Processing Time 0.031 seconds

Sex Ratios of Juveniles Hatched by Constant Temperatures Artificial Incubation From Eggs Collected in the Natural Nest of Soft-Shelled Turtle, Trionyx sinensis Strauch (1862) (한국산 자라, Trionyx sinensis (1862)의 자연산란둥지에서 수거한 난들의 항온인공부화에 의해 출생한 새끼자라들의 성비)

  • KIM, Sung Han
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.702-710
    • /
    • 2017
  • Recently, in many reptiles (14 genera of turtles in five families), common characteristics of incubation temperatures are known to determine the sexes of hatchlings in many species of turtles, including the map turtles, painted turtles and snapping turtles, emys turtle, etc. According to many researcher's reports, in general, incubation at $25^{\circ}C$ (cooler temperatures) produces all or mostly males, however, incubation at $31^{\circ}C$ (higher temperatures) or higher produces all or mostly females. Exceptionally, even cooler temperature ($20^{\circ}C$) produce females, they produced all or mostly females. Accordingly, it is well-known that incubation temperature is the sex determining agent in these turtles. However, this paper presents study of the sex ratio and nest ecology in natural spawning nest: Observations on hatching sex ratios of eggs collected from natural nests of T. sinensis are similar to a previous report of the same genus Trionyx in the soft-shelled turtles. However, this genus (or species) showed some different phenomena to other kinds of turtles such as various kinds turtles mentioned above. After collection of naturally spawned eggs (17 eggs of T. sisnensis) on the natural nests, a laboratory experiment by the constant incubation temperatures was conducted with natural fluctuating soil temperatures in the natural nest with the soft-shelled turtle, T. sinensis. And also laboratory experiments were conducted using constant incubation temperatures of $25^{\circ}C$ (cooler temp.) and $30^{\circ}C$ (higher temp.) with the turtle, T. sinensis. Exceptionally, it was confirmed that the first and second incubation temperatures can't control sex-determination in the freshwater soft-shelled turtle, T. sinensis. The sex ratio approximated 1:1 (${\chi}^2=0.06$, P>0.05 (the Ist experiment). And the sex ratio approximated 1:1 independently of incubation temperature (${\chi}^2=0.33$, P>0.05 (the 2nd experiment). Consequently, temperature has no effect on sex determination in the genus Trionyx in a soft-shelled turtle.

A Study for Improving Spray Uniformity of the SECFR System for Vehicle Applications (SECFR 시스템의 차량적용을 위한 분무균일도향상에 관한 연구)

  • Shon, J.W.;Woo, S.C.;Kim, S.G.;Lee, K.H.
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.95-100
    • /
    • 2015
  • Lower recirculated gas temperature at EGR system reduces NOx and PM emissions. However, EGR Cooler can be polluted by PM generated from recirculated EGR gas, and it reduces cooling efficiency and the amount of EGR gas simultaneously. The SECFR(Steam EGR Cooler Fouling Remover) system which uses the evaporated washer fluid steam caused by high temperature of EGR gas was manufactured for removing fouling generated on the cooler surface. Since an injection pressure of wind shield washer fluid in the vehicle is approximately 0.5 bar, it is not enough to atomize the injected washer fluid. Thus, it is necessary to apply a method to atomize the washer fluid. In this study, the impinging plate was used to promote the atomization of spray washer fluid for the purpose of apply SECFR system to vehicles and measured the DAR(Droplet Area Ratio) and DUI(Droplet Uniformity Index) through the spray visualization.

Isolating Vibration in Miniature Linear Cryogenic Cooler with Tuned Vibration Absorber (동조질량 진동흡수기를 이용한 미니 저온쿨러의 진동 절연)

  • Kim, Young-Keun;Kim, Hong-Bae;Kim, Eung-Hyun;Kim, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.605-609
    • /
    • 2010
  • In modern surveillance equipment, infrared (IR) sensors are essential for detection and observation. The IR sensor is connected to a miniature cryogenic cooler to maintain the temperature at very low levels, i.e., temperatures as low as 77 K. However, the quality of the image captured by the sensor is degraded by the transmission of vibration disturbances from the cooler. Therefore, to maintain high image quality, the compressor vibration and the force transmitted to the sensor have to be mitigated. For the compressor vibration isolating system, a tuned dynamic vibration absorber, combined with a passive isolator, is proposed. A cryogenic compressor bracket and springs are designed to allow the absorber mass to mitigate the vibration jitter in the axial direction. The system design is analyzed and evaluated in terms of the dynamic suppression of the harmonic force at the operating frequency of the cooler.

Analysis on the Thermal Performance of an Ammonia Unit Cooler (암모니아 유니트 쿨러의 열성능 해석)

  • 최재광;김무근;박병규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1125-1133
    • /
    • 2001
  • Since the surface temperature of the evaporating tube in an ammonia unit cooled is lower than the dew point of atmosphere, the moisture in the atmosphere condenses and the frost grows on the tube. The frost of liquid film decreases the heat transfer rate. The reliable analysis of the heat transfer is required for the prediction of the optimal design of the ammonia unit cooler. For the specific commercial model, the performance was numerical1y estimated for the variation of operating condition and geometric configuration. It is found that there exists an optimum range for the parameters such as mass flow rate of air and refrigerant, humidity, refrigerant quality, fin pitch, the number of step, the number of rows and the pattern of refrigerant path.

  • PDF

PI Controller Design of the Refrigeration System Based on Dynamic Characteristic of the Second Order Model

  • Jung, Young-Mi;Jeong, Seok-Kwon;Yang, Joo-Ho
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.200-206
    • /
    • 2014
  • This paper deals with deterministic PI controller design based on dynamic characteristics for refrigeration system. The temperature control system of an oil cooler is described as a typical 2nd order model of the refrigeration system which has zeros in a transfer function. PI controller gains satisfying control specifications are represented by the dynamic characteristic functions using relationship between the parameters and the control specifications in the model. Phase margin was considered to increase robustness of the oil cooler control system. Furthermore, the influence of zeros in the model to the control specifications was analyzed in detail for improving control performance. The validity of the suggested PI controller design was investigated using the four types of gains which had been already confirmed their control performances through experiments.

Operational Mode Analysis of Cooler Driver Electronics in Satellite and System Safety Margin

  • Kim, Kyudong
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.79-84
    • /
    • 2020
  • Cooler driver electronics (CDE) for maintaining low temperature of the satellite payload IR sensor consists of a compressor that has a pulsation current load condition when it is operated. This pulsation current produces large voltage fluctuation, which affects both load and regulated bus stability. Thus, CDE power conditioning system consists of a primary bus, infrared power distribution unit for battery charging and protection, reverse current protection diode, and battery, which is used as a buffer. In this study, the operational mode analysis is performed by each part with equivalent impedance modeling verified through system level simulation. From this mode analysis, the safety margin for state of charge and open circuit voltage of the battery is determined for satisfying the minimum operational voltage of the CDE load.

Investigation of Cooling Effect of Flow Velocity and Cooler Location in Thermal Nanoimprint Lithography

  • Lee, Woo-Young;Lee, Ki Yeon;Kim, Kug Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.37-42
    • /
    • 2012
  • Nanoimprint lithography (NIL) has attracted broad interest as a low cost method to define nanometer scale patterns in recent years. A major disadvantage of thermal NIL is the thermal cycle, that is, heating over glass transition temperature and then cooling below it, which requires a significant amount of processing time and limits the throughput. One of the methods to overcome this disadvantage is to improve the cooling performance in NIL process. In this paper, the performance of the cooling system of thermal NIL is numerically investigated by SolidWorks Flow Simulation program. The calculated temperatures of nanoimprint device were verified by the measurements. By using the analysis model, the effects of the change of flow velocity and cooler location on the cooling performance are investigated. For the 6 cases (0.1 m/s, 0.5 m/s, 1 m/s, 3 m/s, 5 m/s, 10 m/s) of flow velocity and for the 6 cases of distances (50 mm, 40 mm, 30 mm, 20 mm, 10 mm, 1 mm) of cooler location, the heat conjugated flow analyses are performed and discussed.

An Experimental Study on the Heat Exchange Performance at Various EGR Cooler Types (EGR 쿨러 Type에 따른 열교환성능에 관한 실험적 연구)

  • Shon, Jungwook;Woo, Seungchul;Park, Jongwook;Chun, Taesoo;Lee, Kihyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.6
    • /
    • pp.608-614
    • /
    • 2015
  • Nitrogen oxide(NOx) emission reductions are required to meet the strict emission regulations for environmental protection. Most of the Exhaust Gas Recirculation(EGR) system applied to a diesel engine can relatively decrease the NOx at a low cost, but it has a disadvantage in that the PM generation is promoted due to the hot intake air temperature. Thus, high heat exchange efficiency of the EGR cooler is required for an effective removal of NOx. In this study, heat exchange efficiency for various types of heat exchangers used in EGR cooler was measured under same conditions, and determined best heat exchange performance shape depending on type of heat exchanger.

Numerical Simulations on the Thermal Flow and Particle Behaviors in the Gas Reversal Chamber of a Syngas Cooler for IGCC (IGCC 합성가스 냉각기 GRC의 열유동 및 입자거동 특성에 대한 전산해석 연구)

  • Park, Sangbin;Ye, Insoo;Ryu, Changkook;Kim, Bongkeun
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.1
    • /
    • pp.21-26
    • /
    • 2013
  • In the Shell coal gasification process, the syngas produced in a gasifier passes through a syngas cooler for steam production and temperature control for gas cleaning. Fly slag present in the syngas may cause major operational problems such as erosion, slagging, and corrosion, especially in the upper part of the syngas cooler (gas reversal chamber, GRC). This study investigates the flow, heat transfer and particle behaviors in the GRC for a 300 MWe IGCC process using computational fluid dynamics. Three operational loads of 100%, 75% and 50% were considered. The gas and particle flows directly impinged on the wall opposite to the syngas inlet, which may lead to erosion of the membrane wall. The heat transfer to the wall was mainly by convection which was larger on the side wall at the inlet level due to the expansion of the cross-section. In the evaporator below the GRC, the particles were concentrated more on the outer channels, which needs to be considered for alleviation of fouling and blockage.

Development of QCM dew point sensor and its sensing characteristics study (수정미소저울 노점센서 제작 및 반응특성 연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.269-276
    • /
    • 2006
  • This paper represents development of quartz crystal microbalance (QCM) and usage as a dew point sensor. The temperature of a quartz resonator was controlled precisely from $20^{\circ}C$ to $-30^{\circ}C$ with the ramping rate of $0.1^{\circ}C/s$ by using a custom-made crystal holder housing the quartz resonator associated with a thermoelectric cooler (Peltier cooler), which results in the working range from $15.2^{\circ}C$ to $-24.0^{\circ}C$ based on an accurate holder temperature compensation and temperature effect compensation process. The developed QCM dew point sensor and analysis techniques show very good sensing characteristics at measurement of moist air with the relative humidity from 10 %R.H. to 90 %R.H. generated by a divided-type humidity generator and the dew point temperatures were determined with an accuracy of less than ${\pm}0.18^{\circ}C$, which also showed good agreement with reference values in their error range.