An Experimental Study on the Heat Exchange Performance at Various EGR Cooler Types  

Shon, Jungwook (Graduate School of Mechanical Engineering, Hanynag University)
Woo, Seungchul (Graduate School of Mechanical Engineering, Hanynag University)
Park, Jongwook (Heat Exchanger Development Team, Hanon Systems)
Chun, Taesoo (Heat Exchanger Development Team, Hanon Systems)
Lee, Kihyung (Department of Mechanical Engineering, Hanynag University)
Publication Information
Transactions of the Korean Society of Automotive Engineers / v.23, no.6, 2015 , pp. 608-614 More about this Journal
Abstract
Nitrogen oxide(NOx) emission reductions are required to meet the strict emission regulations for environmental protection. Most of the Exhaust Gas Recirculation(EGR) system applied to a diesel engine can relatively decrease the NOx at a low cost, but it has a disadvantage in that the PM generation is promoted due to the hot intake air temperature. Thus, high heat exchange efficiency of the EGR cooler is required for an effective removal of NOx. In this study, heat exchange efficiency for various types of heat exchangers used in EGR cooler was measured under same conditions, and determined best heat exchange performance shape depending on type of heat exchanger.
Keywords
EGR cooler; Heat exchange efficiency; Fin-tube heat exchanger; Shall-tube heat exchanger;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 K. W. Choi, B. H. Moon, K. B. Kim and K. H. Lee, "A Study on the Combustion Characteristics by EGR Gas Temperature in Diesel Engine," The 41th KOSCO Symposium, pp.355-359, 2010.
2 K. P. Patel, Study of NOx and Loading of a Soot Filter versus EGR for a 2.4L Diesel engine, M. S. Thesis, University of Tennessee, Koxville, 2001.
3 J. Lee, J. I. Moon and Y. H. Kim, "A Study on Heat Exchange Efficiency of EGR Cooler for Diesel Hybrid," Transactions of KSAE, Vol.17, No.2, pp.159-164, 2009.
4 S. J. Hwang, M. C. Kim, S. H. Jang and H. M. Kim, "Effects of Pitch Length of Stack-type EGR Cooler on Heat Exchange Characteristics in a Diesel Engine," Transactions of KSAE, Vol.18, No.2, pp.135-140, 2010.
5 Y. H. Seo, S. H. Heo, T. W. Ku, W. J. Song, J. Kim and B. S. Kang, "Study on Heat Exchanger Efficiency of EGR Cooler with Dimpled Rectangular Tube Shape for Application of Diesel Vehicles," Transactions of KSME-B, Vol.32, No.10, pp.769-775, 2008.
6 H. S. Huh and Y. K. Suh, "Study on the Heat Transfer Characteristics for Some EGR-cooler Designs," Annual Spring Conferences of KSME, pp.1306-1310, 2002.