• 제목/요약/키워드: Temperature history

검색결과 677건 처리시간 0.027초

고압에서의 액적의 증발현상에 관한 연구 (Investigation of Droplet Vaporizatio Phenomena in High Pressure Environments)

  • 이현창;백승욱
    • 한국연소학회지
    • /
    • 제13권3호
    • /
    • pp.17-23
    • /
    • 2008
  • The spray combustion and spray cooling depends on droplet evaporation. So, evaporation model for spray has been requested and lots of investigation has been done and various reliable models have been developed also for last few decades. In the present study, One dimensional quasi-steady spherically symmetric droplet evaporation model for micro-gravity is developed. The gas phase was assumed as steady state and the thermophysical properties are calculated as a function of temperature, pressure and composition and the properties used in the model was validated by NIST web data and overall evaporation history results was compared with experimental results by Nomura and Qasim and gave satisfactory agreements. Through this model, diverse phenomenon was investigated, especially regarding the effects of ambient pressure and temperature. The effects of pressure for the droplet evaporation time were studied. The high pressure increased the droplet surface temperature and made effect on the evaporation time depend on atmospheric temperature. The role of the ambient temperature was investigated and explained. The basic investigation for the evaporation process according to variation of droplet diameter and surface temperature were also investigated and the well-known phenomena, like D-square-law, were reported, too.

  • PDF

열가소성 폴리머 필름의 마이크로 점착 거동에 대한 온도의 영향 (Effect of Temperature on the Micro-scale Adhesion Behavior of Thermoplastic Polymer Film)

  • 김광섭;허정철;김경웅
    • Tribology and Lubricants
    • /
    • 제25권2호
    • /
    • pp.86-95
    • /
    • 2009
  • Adhesion tests were carried out in order to investigate the effect of temperature on the adhesion behavior between a PMMA film and a fused silica lens in the micro scale. For the tests, a microtribometer system was specially designed and constructed. The pull-off forces on the PMMA film were measured under atmospheric condition as the temperature of the PMMA film was increased from 300 K to 443 K and decreased to 300 K. The contact area between the PMMA film and the lens was observed during the test. The adhesion behavior was changed with the change of the PMMA surface state as the temperature increased. In glassy state below 363 K, the pull-off force did not change with the increase of temperature. In rubbery state from 383 K to 413 K, the pull-off force increased greatly as the temperature increased. In addition, the area of contact was enlarged. In viscous state above 423 K, the fingering instability was observed in the area of contact when the PMMA film contacted with the lens. It was also found that the adhesion behavior can be varied with the thermal history of the PMMA film. The residual solvent in the PMMA film could emerge to the PMMA surface due to the heating and reduced the pull-off force.

양생온도 이력 기록장치를 이용한 현장타설 콘크리트의 품질검사 (Quality Inspection for Cast-In-Place Concrete with the Device to Record Curing Temperature)

  • 조영권;김관호;김명원;이준구;유정훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.351-354
    • /
    • 2005
  • Quality of concrete required to achieve the desired levels of strength and durability depend on the effectiveness of the curing method. During cold weather, the concrete at the time of placement should be taken to prevent damage to concrete due to freezing. Since the cement-water reaction is exothermic by nature, the temperature within mass concrete can be quite high. The temperature control for massive sections should be taken more careful than for shallow sections. However, in the constructing hydraulic structures, the curing temperature control for concrete had been very difficult to be taken in a proper way because the conditions constructing them are poor and contractors are small enterprises. For several. reasons including above, Rural Research Institute has developed a device and program for recording curing temperature history in cold weather concrete and mass. As there are two major advantages of the device, namely cheapness and availability, this program and device has been recommended to the use of curing temperature control in cold weather concrete and mass.

  • PDF

저온환경에서의 양생시트 변화에 따른 콘크리트의 온도이력 특성 (Temperature History of the Concrete Corresponding to Various Curing Sheets in the Low Temperature)

  • 백대현;홍석민;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.781-784
    • /
    • 2008
  • 본 연구에서는 저온 환경에서 단열양생시트 변화에 따른 콘크리트의 온도이력 및 강도특성을 검토하였다. 실험결과 -5$^{\circ}$C에서 노출과 air cap포장지의 경우 초기 24시간 이내로 콘크리트의 온도가 영하의 온도로 저하되어 초기동해가 발생되었다. 반면, 비닐+부직포의 경우 초기 24시간이내의 최저온도가 약 3$^{\circ}$C로 영상의 온도를 유지하였고 이중버블시트의 경우 약 7$^{\circ}$C로 나타나 양호한 단열 보온성능을 나타내었다. 코어압축강도를 측정한 결과 비닐+부직포와 이중버블시트로 양생한 시험체의 압축강도가 양생초기의 우수한 단열효과로 인해 다른 시험체의 압축강도보다 높게 나타났다.

  • PDF

ANALYSIS OF PRESTRESSED CONCRETE CONTAINMENT VESSEL (PCCV) UNDER SEVERE ACCIDENT LOADING

  • Noh, Sang-Hoon;Moon, Il-Hwan;Lee, Jong-Bo;Kim, Jong-Hak
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.77-86
    • /
    • 2008
  • This paper describes the nonlinear analyses of a 1:4 scale model of a prestressed concrete containment vessel (PCCV) using an axisymmetric model and a three-dimensional model. These two models are refined by comparison of the analysis results and with testing results. This paper is especially focused on the analysis of behavior under pressure and the temperature effects revealed using an axisymmetric model. The temperature-dependent degradation properties of concrete and steel are considered. Both geometric and material nonlinearities, including thermal effects, are also addressed in the analyses. The Menetrey and Willam (1995) concrete constitutive model with non-associated flow potential is adopted for this study. This study includes the results of the predicted thermal and mechanical behaviors of the PCCV subject to high temperature loading and internal pressure at the same time. To find the effect of high temperature accident conditions on the ultimate capacity of the liner plate, reinforcement, prestressing tendon and concrete, two kinds of analyses are performed: one for pressure only and the other for pressure with temperature. The results from the test on pressurization, analysis for pressure only, and analyses considering pressure with temperatures are compared with one another. The analysis results show that the temperature directly affects the behavior of the liner plate, but has little impact on the ultimate pressure capacity of the PCCV.

조강성 시멘트 종류에 따른 콘크리트의 온도이력 및 압축강도 특성 (Temperature and Compressive Strength of the Concrete According to the Types of Rapid Hardening Cements)

  • 김상민;최윤호;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.100-101
    • /
    • 2020
  • In this study, the temperature history and compressive strength of the concretes according to the type of cement were measured and analyzed in comparison as part of the experiment on the material mixing side to reduce the hydration heat crack of the mat foundation constructed with mass concrete. As a result, the peak temperature and maximum temperature reach time of concrete using high rapid cement were shown to be similar to that of semi rapid cement. In particular, in compressive strength after three days, semi rapid cement was measured higher than that of concrete using high rapid cement. Therefore, if semi rapid cement is used in accordance with the site conditions, it is deemed possible to shorten the air due to reduction of temperature cracks and improvement of initial strength.

  • PDF

고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

파이프 쿨링을 고려한 수화열 해석기법에 관한연구 (Themal Stress Analysis of the Heat of Hydration Considering Pipe-Cooling)

  • 긴진근;김국한;최계식;양주경;최고일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.274-279
    • /
    • 1995
  • The heat of hyderation of cement causes the internal temperature rise and volume change at early age, paticular in massive concrete structures. As the results of the temperature rise and extenal restraint conditions, the themal stress may induce cracks in concrete. Therefore various techenuques of the themal stress control of the mass concrete has been widely used. One of these techniques is pipe-cooling which is considered in this study. The objective of this paper is to develop finite element program which is capable of simulating the temperature history and the thermal stress considering pipe-cooling, creep and the modified elastic modulus dud to maturity effect.

  • PDF

내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구 (An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form)

  • 김경민;손성운;김기철;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

유체 충격 압력 측정용 압전 센서 특징 (Characteristics of Piezoelectric Sensor for Fluid Impact Pressure)

  • 최영명;김현이;박준수;권순홍;김동진
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.17-22
    • /
    • 2009
  • This study presents an investigation of the characteristics of piezoelectric sensors whose main utilization is to measure impact pressure. The piezoelectric sensors were tested from several points of view. Their characteristics were investigated for repeatability, the effect of the diameter, temperature effect, water purity, flush mounting, and AC and DC coupling. Out of these, it was revealed that the temperature effect is very significant. The characteristics of the AC and DC coupling are also very important in understanding the time history of the impact pressure.