• 제목/요약/키워드: Temperature Difference Measurement

검색결과 446건 처리시간 0.026초

복강경하 자궁근종절제술 후 적용한 온열요법이 가스 통증, 수술 후 회복력 및 체온불편감에 미치는 효과 (Influence of Gas Pain, Post-operative Resilience, and Body Temperature Discomfort in Laparoscopic Myomectomy Patients after Thermotherapy)

  • 이정애;전명화;박은주;이진아;안곤명;이승신;김지인
    • 여성건강간호학회지
    • /
    • 제25권1호
    • /
    • pp.4-18
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of thermotherapy on gas pain, post-operative resilience, and body temperature discomfort among patients who received laparoscopic myomectomies. Methods: The experimental group consisted of 62 patients with thermotherapy and the control group consisted of 60 patients. Thermotherapy was applied individually to the experimental group four hours after surgery. The collected data was analyzed using descriptive statistics, t-tests, ${\chi}^2$-tests, and repeated measures of analysis of variance, using IBM SPSS Statistics version 18. Results: The results showed no significant interaction effect between the group and time of measurement in gas-related pain in the experimental group. For gas-related pain, there was significant difference in right shoulder pain at 24 hours (t=-4.222, p=.000), 48 hours (t=-3.688, p=.000), 72 hours (t=-2.250, p=.028), and left at 24 hours (t=-3.727, p=.000), 48 hours (t=-4.150, p=.000), and 72 hours (t=-2.482, p=.016) and both shoulders at 24 hours (t=-2.722, p=.009) and 48 hours (t=-2.525, p=.014). There was no significant difference in epigastric pain, excluding both epigastric pain at 48 hours (t=2.908, p=.005), 72 hours (t=3.010, p=.004), but there was a significant difference in objective body temperature discomfort (t=2.895, p=.008). Conclusion: Thermotherapy relieved shoulder gas-related pain and objective body temperature discomfort. It needs to be developed and applied to improve post-operative discomfort in patients with laparoscopic hysterectomies.

ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구 (A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case)

  • 이정일
    • 한국재난정보학회 논문집
    • /
    • 제16권2호
    • /
    • pp.383-391
    • /
    • 2020
  • 연구목적 : 에너지 저장실의 외부 화염에 의한 내부자기 점화 및 점화를 식별하고, 과열로 인한 점화와 외부 열원에 의한 점화의 차이를 분석하는 것이다. 연구방법 : 분리막 녹는점 측정, 배터리 외부 수열 실험, 배터리 과충전 실험, 과충전과 외부수열에 의한 연소 시 전극 판 비교분석, 과충전 연소 특징, 외부수열 화재 연소특징, 3.4(전극판 비교)/ 3.5(과충전)/ 3.6(외부수열) 분석 실험을 하였다. 연구결과: 화재 발생 시까지 센서의 위치에 따른 온도 차이가 극심했음으로 기존처럼 한 모듈 당 온도 센서 두 개로는 측정값이 부족해 온도제어를 통한 화재를 사전에 방지할 수 없다고 판단한다. 결론: 단락이 점화원으로 작용하여 혼합가스에 착화돼 가스폭발이 발생하고, 폭발 압력에 의해 전극이 잘게 파손되며, 가루형태의 리튬산화물이 불꽃반응에 의해 폭죽과 유사한 불꽃이 분출되었다.

열간 압연공정의 강판 온도 분포 해석 (Bar Temperature Analysis of a Hot Rolling Process.)

  • 백기남;고명삼
    • 대한전기학회논문지
    • /
    • 제38권4호
    • /
    • pp.307-315
    • /
    • 1989
  • 본 논문에서는 열간압연공정중 소재가 가열로에서 추출되어 조압연 공정을 마치기 까지 소재인 slab의 온도변화추이를 해석키 위하여 rolling process 상에서 온도에 영얄을 미치는 인자인 1) 대기중 복사 및 대류에 의한 냉각 2) 소성가공발열 3) descaling water에 의한 수냉각 4) rolling roll, 운반 roll과의 접촉냉각등 제요인에 관한 사항을 rolling process 상에서의 문제로 평가도입하여 해석하고저 하는 slab 표면에서의 경계조건 설정과 관련한 적용기법을 정립하였고 소재의 냉각 현상을 two dimensional transient heat flow문제로 취급, 유한차분방정식을 이용하여 해석하는 과정과 관련 rollinh작업을 sequence화 하여 적용하는 기법을 제시하였다. simulation 결과 계산치와 실계측편차 (${\pm}18^{\circ}C$)범위내에서 일치함을 제시하였고 또한 rolling event 별로 나타나는 온도하강 pattern이 실제의 압연상황과 잘 일치함을 제시하므로서 본 computer simulation 과정에서 적용한 가정, 조건, 물성치 등의 적정성 등을 입증하였다.

NR, SBR, BR 가황물의 원형 변형으로부터의 회복 거동 (Recovery Behaviors of NR, SBR and BR Vulcanizates from Circular Deformation)

  • 장중희;최성신
    • Elastomers and Composites
    • /
    • 제44권4호
    • /
    • pp.442-446
    • /
    • 2009
  • 충전제의 영향을 막기 위해 비보강 NR, BR, SBR 고무 가황물을 원형 변형시켜 노화시킨 후 회복 거동을 비교하였다. 시료는 상온, 50, 70, $90^{\circ}C$에서 10일간 노화시켰다. 측정 시간이 증가함에 따라 회복률은 증가하였다. 노화 후 측정 시간에 따른 회복률의 변화로부터 1.0 초 미만의 순간회복률을 구하였다. 상온 노화에서는 노화 기간이 짧아 고무 간의 회복률 차이가 거의 나타나지 않았다. 하지만 50, 70, $90^{\circ}C$에서의 가속 노화 실험 결과에서는 각 고무 간의 회복률 차이가 뚜렷하게 나타났다. BR의 회복률이 가장 우수하였고, SBR의 회복률이 가장 적었다. 그러나 $90^{\circ}C$ 가속 노화 에서는 NR의 회복률이 BR보다 높게 나타났다. 노화 온도가 높아 질수록 초기 회복률이 감소하였으며, 그 감소 폭은 SBR이 가장 크게 나타났다. 실험 결과는 고무의 반발 특성과 노화에 의한 가교밀도 변화로 설명하였다.

콘크리트 슬래브가 없는 강재주형에서 상하연 온도차에 대한 실측연구 (An Experimental Study on the Temperature Difference between the Top and Bottom Flange in Steel Girder without Concrete Slab)

  • 신동욱;김경남;정경섭;이성행
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권4호
    • /
    • pp.99-106
    • /
    • 2014
  • 합리적인 온도 설계하중을 연구하기 위하여, 실제 크기의 콘크리트 슬래브가 없는 강상형 거더 교량 시험체를 제작하였다. 높이에 따라 부착된 18개의 온도 게이지에서 5개월 동안 온도 데이터를 측정하였다. 강상형 거더 교량 시험체의 상단과 하단 사이의 온도 차가 계산되고, 온도 구배 모형이 확률 방법으로 제안되었다. 본 연구에서 제시된 모형은 유로 코드에 의해 제안 된 모델과 비교했을 때 약 97%의 상관관계를 보인다. 따라서, 본 연구의 결과로 제안 된 온도 구배 모델은 온도 설계 하중 계산시 기초 자료로 활용 될 수 있다.

온도센서 배열 모니터링에 의한 매질의 투수성 및 절리 연결성 연구 (A Study on the medium seepage and the fracture connectivity by using temperature monitoring with thremal line sensors)

  • 김중열;김태희;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.1110-1119
    • /
    • 2006
  • If water flows through a narrow passage into a medium that keeps the equilibrium of temperature, it causes small temperature difference and makes a temperature anomaly. The seepage or leakage often observed at old dams is a representative example of bringing about a temperature anomaly. Therefore, temperature measurements have been regarded as one of excellent methods that can detect the situation of seepage or leakage. However, because existing temperature measurement methods are based on a single sensor, the application of the method to the whole structure is nearly not possible in technical and economical phases. This paper introduces a temperature monitoring system using a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel at many positions within a single cable. Through various laboratory and field experiments, it has been proved that the temperature monitoring technique can give an useful information about permeability of a medium or connectivity of fractures which have been regarded as difficult problems.

  • PDF

니켈실리사이드의 색차분석 (Color Difference Characterization on Nickel Silicides)

  • 정영순;송오성;김득중;최용윤;김종준
    • 한국표면공학회지
    • /
    • 제38권1호
    • /
    • pp.44-48
    • /
    • 2005
  • We prepared nickel silicide layers from p-Si(l00)/SiO₂(2000 Å)/poly-Si(700 Å)/Ni(400 Å) structures, feasible for gates in MOSFETs, by annealing them from 500℃~900℃ for 30 minutes. We measured the color coordination in visible range, cross sectional micro-structure, and surface topology with annealing temperature by an UV-VIS-IR spectrometer, field effect scanning electron microscope(FE-SEM), and scanning probe micro-scope respectively. We conclude that we may identify the nickel silicide by color difference of 0.90 and predict the silicide process reliability by color coordination measurement. The nickel silicide layers showed similar thickness while the columnar grains size and surface roughness increased as annealing temperature increased.

옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰 (Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System)

  • 유동철;이응직;이두호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • 제1권1호
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.

한강 하류부의 수질변동에 대한 추계학적 특성(I) - 특히 뚝도 및 노량진 지점의 DO, 탁도, 수온의 변동을 중심으로 - (Stochastic Properties of Water Quality Variation in Downstream Part of Han River)

  • 이홍근
    • 물과 미래
    • /
    • 제15권3호
    • /
    • pp.23-36
    • /
    • 1982
  • The stochastic variations and structures of time series data on water quality were examined by employing the techniques of autocorrelation function, variance spectrum, Fourier series, autoregressive model and ARIMA model. These time series included hourly and daily observation on DO, turbidity, conductivity pH and water temperature. The measurement was made by automatic recording instrument at Noryangjin and Dook-do located in the downstream part of Han River during 1975 and 1976. Hourly water quality time series varied with the dominant 24-hour periodicity, and the 12-hour periodicity was also observed. An important factor affecting 24-hour periodic variation of DO is believed to be photosynthesis by algae. These phenomena might be attributable to periodic discharges of municipal sewage. Noryangjin site showed the more distinct 12-hour periodicity than Dook-do site did, and tidal effect might be responsible for the difference. The water quality, as measured by DO and turbidity, was better in the afternoon compared with the quality in the morning. This change can be explained by the periodic variation of DO, temperature and the amount of municipal wewage discharge. It was also observed that the water temperature at Noryangjin was higher than the temperature at Dook-do. This difference might have been caused by the pollutants that were added to the section between two sites. The correlation coefficients between some of the variables were fairly high. For example, the coefficient was -0.88 between DO and water temperature, 0.75 between turbidity and river flow, and 0.957 between water temperature and air temperature. The lag time of heat transfer from the air to the water was estimated as 24 days. The first order auto-regressive model was appropriate for explaning standardized hourly DO time series. The ARIMA model of (1, 0, 0) type provided relatively satisfactory results for daily DO time series after the removal of significant harmonic value.

  • PDF