• Title/Summary/Keyword: Temperature Difference Measurement

Search Result 446, Processing Time 0.029 seconds

Influence of Gas Pain, Post-operative Resilience, and Body Temperature Discomfort in Laparoscopic Myomectomy Patients after Thermotherapy (복강경하 자궁근종절제술 후 적용한 온열요법이 가스 통증, 수술 후 회복력 및 체온불편감에 미치는 효과)

  • Lee, JeongAe;Jeon, MyoungHwa;Park, EunJu;Lee, JinAh;Ahn, GonMyoung;Lee, SeungShin;Kim, JiIn
    • Women's Health Nursing
    • /
    • v.25 no.1
    • /
    • pp.4-18
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effects of thermotherapy on gas pain, post-operative resilience, and body temperature discomfort among patients who received laparoscopic myomectomies. Methods: The experimental group consisted of 62 patients with thermotherapy and the control group consisted of 60 patients. Thermotherapy was applied individually to the experimental group four hours after surgery. The collected data was analyzed using descriptive statistics, t-tests, ${\chi}^2$-tests, and repeated measures of analysis of variance, using IBM SPSS Statistics version 18. Results: The results showed no significant interaction effect between the group and time of measurement in gas-related pain in the experimental group. For gas-related pain, there was significant difference in right shoulder pain at 24 hours (t=-4.222, p=.000), 48 hours (t=-3.688, p=.000), 72 hours (t=-2.250, p=.028), and left at 24 hours (t=-3.727, p=.000), 48 hours (t=-4.150, p=.000), and 72 hours (t=-2.482, p=.016) and both shoulders at 24 hours (t=-2.722, p=.009) and 48 hours (t=-2.525, p=.014). There was no significant difference in epigastric pain, excluding both epigastric pain at 48 hours (t=2.908, p=.005), 72 hours (t=3.010, p=.004), but there was a significant difference in objective body temperature discomfort (t=2.895, p=.008). Conclusion: Thermotherapy relieved shoulder gas-related pain and objective body temperature discomfort. It needs to be developed and applied to improve post-operative discomfort in patients with laparoscopic hysterectomies.

A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case (ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.383-391
    • /
    • 2020
  • Purpose: To identify internal self ignition and ignition caused by external flames in energy storage rooms, and to analyze the difference between ignition due to overheating and ignition caused by external heat sources. Method: membrane melting point measurement, battery external hydrothermal experiment, battery overcharge experiment, comparative analysis of electrode plate during combustion by overcharge and external heat, overcharge combustion characteristics, external hydrothermal fire combustion characteristics, 3.4 (electrode plate comparison) / 3.5 (overcharge) /3.6 (external sequence) analysis experiment. Result: Since the temperature difference was very different depending on the position of the sensor until the fire occurred, it is judged that two temperature sensors per module are not enough to prevent the fire through temperature control in advance. Conclusion: The short circuit acts as an ignition source and ignites the mixed gas, causing a gas explosion. The electrode breaks finely due to the explosion pressure, and the powder-like lithium oxide is sparked like a firecracker by the flame reaction.

Bar Temperature Analysis of a Hot Rolling Process. (열간 압연공정의 강판 온도 분포 해석)

  • 백기남;고명삼
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.4
    • /
    • pp.307-315
    • /
    • 1989
  • In this paper, we have analyzed the temperature variation trend of a slab on between the process of reheating furnace and the termination of roughing mill process during hot rolling process. 1) cooling by radiation and convection current in the air, 2) plastic deformation heat, 3) cooling by descaling water, 4) cooling by contact with rolling rolls and/or transmitting rolls. For the analysis, the factors have been adopted as the problems of the rolling process to be solved such that we have established an application technique in relation to the determination of boundary conditions on the slab surface. We have presented a procedure for an analysis of the cooling phenomenon treated as a problem of two-dimensional transient heat flow using finite difference equation and suggested techniques of implementing sequentialized rolling tasks in correlation with the procedure. From the result of simulation, it is shown that the difference between calculation value and measurement value is within the range of the industrial measurement error. Also, it is proved that the assumptions, conditions, and properties used in the computer simulation is appropriate by showing that the pattern of a drop in temperature at each rolling event is in accord with real circumstances.

Recovery Behaviors of NR, SBR and BR Vulcanizates from Circular Deformation (NR, SBR, BR 가황물의 원형 변형으로부터의 회복 거동)

  • Jang, Joong-Hee;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.442-446
    • /
    • 2009
  • Recovery behaviors of unfilled NR, BR, and SBR vulcanizates after aging with a circular deformation were compared to prevent the influence of reinforcing agent. Samples were aged at room temperature, 50, 70, and $90^{\circ}C$ for 10 days. Recovery increased by increasing the measurement time. Instantaneous recoveries less than 1.0 sec were obtained using the recovery variations with the measurement time. For aging at room temperature, difference in the recoveries of the rubber samples was not significant because the aging time was too short. However, for accelerated thermal aging at 50, 70, and $90^{\circ}C$, difference in the recoveries of the rubber samples was significant. Degree of recovery of BR specimen was higher than those of the others, while that of SBR was lowest. However, for accelerated thermal aging at $90^{\circ}C$, recovery of the NR sample was higher than that of the BR one. The initial recovery decreased by increasing the aging temperature and the decrement of SBR was larger than the others. The experimental results were explained with the resilience properties of rubbers and the crosslink density changes by thermal aging.

An Experimental Study on the Temperature Difference between the Top and Bottom Flange in Steel Girder without Concrete Slab (콘크리트 슬래브가 없는 강재주형에서 상하연 온도차에 대한 실측연구)

  • Shin, Dong-Wook;Kim, Kyoung-Nam;Jung, Kyoung-Sup;Lee, Seong-Haeng
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.99-106
    • /
    • 2014
  • In order to study the reasonable design thermal loads, the steel box girder bridge specimen which have no concrete slab was manufactured with the real size dimension. The temperature data were measured for 5 month at the 18 thermo gauges which were attached according to height. The temperature differences between the top and bottom flange in steel box girder specimen were calculated and the temperature gradient models were proposed by the probabilistic method. This proposed model showed a correlation of approximately 97% when compared with the similar model of Euro Code. Thus, the temperature gradient models which were suggested in this study may be used as the basis data in calculating the design load temperature.

A Study on the medium seepage and the fracture connectivity by using temperature monitoring with thremal line sensors (온도센서 배열 모니터링에 의한 매질의 투수성 및 절리 연결성 연구)

  • Kim, Jung-Yul;Kim, Tae-Hee;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1110-1119
    • /
    • 2006
  • If water flows through a narrow passage into a medium that keeps the equilibrium of temperature, it causes small temperature difference and makes a temperature anomaly. The seepage or leakage often observed at old dams is a representative example of bringing about a temperature anomaly. Therefore, temperature measurements have been regarded as one of excellent methods that can detect the situation of seepage or leakage. However, because existing temperature measurement methods are based on a single sensor, the application of the method to the whole structure is nearly not possible in technical and economical phases. This paper introduces a temperature monitoring system using a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel at many positions within a single cable. Through various laboratory and field experiments, it has been proved that the temperature monitoring technique can give an useful information about permeability of a medium or connectivity of fractures which have been regarded as difficult problems.

  • PDF

Color Difference Characterization on Nickel Silicides (니켈실리사이드의 색차분석)

  • Jung Youngsoon;Song Ohsung;Kim Dugjoong;Choi Yongyun;Kim Chongjun
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.1
    • /
    • pp.44-48
    • /
    • 2005
  • We prepared nickel silicide layers from p-Si(l00)/SiO₂(2000 Å)/poly-Si(700 Å)/Ni(400 Å) structures, feasible for gates in MOSFETs, by annealing them from 500℃~900℃ for 30 minutes. We measured the color coordination in visible range, cross sectional micro-structure, and surface topology with annealing temperature by an UV-VIS-IR spectrometer, field effect scanning electron microscope(FE-SEM), and scanning probe micro-scope respectively. We conclude that we may identify the nickel silicide by color difference of 0.90 and predict the silicide process reliability by color coordination measurement. The nickel silicide layers showed similar thickness while the columnar grains size and surface roughness increased as annealing temperature increased.

Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System (옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰)

  • Yoo, Dong-Chul;Lee, Eung-Jik;Lee, Doo-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.

Stochastic Properties of Water Quality Variation in Downstream Part of Han River (한강 하류부의 수질변동에 대한 추계학적 특성(I) - 특히 뚝도 및 노량진 지점의 DO, 탁도, 수온의 변동을 중심으로 -)

  • 이홍근
    • Water for future
    • /
    • v.15 no.3
    • /
    • pp.23-36
    • /
    • 1982
  • The stochastic variations and structures of time series data on water quality were examined by employing the techniques of autocorrelation function, variance spectrum, Fourier series, autoregressive model and ARIMA model. These time series included hourly and daily observation on DO, turbidity, conductivity pH and water temperature. The measurement was made by automatic recording instrument at Noryangjin and Dook-do located in the downstream part of Han River during 1975 and 1976. Hourly water quality time series varied with the dominant 24-hour periodicity, and the 12-hour periodicity was also observed. An important factor affecting 24-hour periodic variation of DO is believed to be photosynthesis by algae. These phenomena might be attributable to periodic discharges of municipal sewage. Noryangjin site showed the more distinct 12-hour periodicity than Dook-do site did, and tidal effect might be responsible for the difference. The water quality, as measured by DO and turbidity, was better in the afternoon compared with the quality in the morning. This change can be explained by the periodic variation of DO, temperature and the amount of municipal wewage discharge. It was also observed that the water temperature at Noryangjin was higher than the temperature at Dook-do. This difference might have been caused by the pollutants that were added to the section between two sites. The correlation coefficients between some of the variables were fairly high. For example, the coefficient was -0.88 between DO and water temperature, 0.75 between turbidity and river flow, and 0.957 between water temperature and air temperature. The lag time of heat transfer from the air to the water was estimated as 24 days. The first order auto-regressive model was appropriate for explaning standardized hourly DO time series. The ARIMA model of (1, 0, 0) type provided relatively satisfactory results for daily DO time series after the removal of significant harmonic value.

  • PDF