• 제목/요약/키워드: Temperature Difference Energy

검색결과 1,097건 처리시간 0.037초

미활용에너지의 경제적 효과 및 보급지원방안 연구 (Study on Economic analysis and Dessemination Policy of Unused Energy)

  • 안형준;백성권;허은녕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2008
  • Temperature difference energy is a good energy source replacing the fossil fuels. In the study, we classified the temperature difference energy as 4 types by the source & using method. For the understanding economic property of temperature difference energy, we tried simle economic analysis. As the result, Pay back period of 4 case of the temperature difference energy are from 1.23 to 12.65 years. Major factors influenced economic effect are operation time and energy user distance from the temperature difference energy source. If we can select optimal capacity and look for more effient energy users, Temperature difference energy play a important role of replacing fossil energy. So, for dess emination of temperature difference energy, we suggest that temperature difference energy must be included in renewable energy. Applying the effective methods among various promotion program of renewable energy policy, utilization of temperature difference energy could be activated.

  • PDF

수도권 팔당취수장 원수 이용 온도차에너지 부존량 조사 (Evaluation of Water Temperature Difference Energy of the Raw Water from Paldang Water Intake Station)

  • 조용;박진훈;김영준;박태진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.170.2-170.2
    • /
    • 2010
  • The amount of the heating and cooling energy of water source heat pump using the raw water from the Paldang water intake station is investigated in the study. The Han river water is conveyed in the large-size shallowly buried pipe. Averaged water temperature at the position, 27 km from the Paldang water intake station, is increased by $1.11^{\circ}C$ due to the geothermal energy transfer under the ground, therefore the raw water has more thermal energy than the river water. To estimate of the thermal energy for the raw water, it is assumed that the water source heat pump is used for the heating and cooling ventilation. When $5.0^{\circ}C$ temperature difference energy of the raw water is used in the heat pump system all the year except for the January and February in which $3.0^{\circ}C$ temperature difference energy is used. It is predicted that total 5,766.3 Tcal could be used in the metropolitan area a year, which is about 3.0% of the river water unutilized energy resources.

  • PDF

유기랭킨사이클에서 핀치온도차의 변화에 따른 열교환기의 열역학적 성능특성 (Characteristics of Thermodynamic Performance of Heat Exchanger in Organic Rankine Cycle Depending on Pinch Temperature Difference)

  • 김경훈;정영관;박상희
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.590-599
    • /
    • 2015
  • In this paper a performance analysis is carried out based on the first and second laws of thermodynamics for heat exchanger in organic Rankine cycle (ORC) for the recovery of low-temperature finite thermal energy source. In the analysis, effects of the selection of working fluid and pinch temperature difference are investigated on the performance of the heat exchanger including the effectiveness of the heat exchanger, exergy destruction, second-law efficiency, number of transfer unit (NTU), and pinch point. The temperature distribution are shown depending on the working fluids and the pinch temperature difference. The results show that the performance of the heat exchanger depends on the pinch temperature difference sensitively. As the pinch temperature increases, the exergy destruction in the evaporator increases but the effectiveness, second law efficiency and NTU decreases.

LNG 선박 하이브리드 엔진 및 해수 담수화 복합 시스템 (LNG-Vessels Hybrid Engine Seawater Desalination Complex System)

  • 임재준;이동헌;변기식;김관형
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.663-664
    • /
    • 2016
  • 해수를 이용한 온도차 발전은 심층수와 표층수의 온도 차이를 이용한 암모니아(냉매)를 사용하여 폐쇄적인 액화와 기화를 반복하여 터빈을 돌리는 방식이다. 온도차 발전의 특성상 온도 차이가 클수록 에너지 발전 특성은 좋아진다. 이는 심층수 표층수의 온도차이가 커야 됨을 이야기 한다. 하지만 겨울이 되면 표층수와 심층수의 온도차이가 크지 않아 에너지 효율이 떨어지는 문제점이 있다. 그리고 해수 담수화기술은 지구의 97%를 차지하지만 우리가 먹을 수 없는 바닷물을 담수로 바꾸는 기술로, 해수 담수화기술로 생산된 담수는 선박내의 공업, 식수 등 각종 용수로 사용할 수 있다. 본 논문에서는 현재 문제가 되고 있는 계절에 따른 표층수의 온도 변화를 개선하기 위해 기존에 사용하고 있는 선박용 디젤엔진의 열에너지와 LNG의 냉열 에너지를 사용한 온도차 발전을 위해 LNG 운송 선박을 기준으로 LNG 운송 선박 하이브리드 엔진에 관한 연구와 냉열 에너지를 활용한 해수 냉동법으로 담수화하는 발전 및 담수화를 복합시킨 연구를 제시하고자 한다.

  • PDF

3 MWth 급 매체순환연소 시스템의 운전변수 변화에 따른 성능 예측 (Performance Prediction of 3 MWth Chemical Looping Combustion System with Change of Operating Variables)

  • 류호정;남형석;황병욱;김하나;원유섭;김대욱;김동원;이규화;전명훈;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.419-429
    • /
    • 2022
  • Effects of operating variables on temperature profile and performance of 3 MWth chemical looping combustion system were estimated by mass and energy balance analysis based on configuration and dimension of the system determined by design tool. Air reactor gas velocity, fuel reactor gas velocity, solid circulation rate, and solid input percentage to fluidized bed heat exchanger were considered as representative operating variables. Overall heat output and oxygen concentration in the exhaust gas from the air reactor increased but temperature difference decreased as air reactor gas velocity increased. Overall heat output, required solid circulation rate, and temperature difference increased as fuel reactor gas velocity increased. However, overall heat output and temperature difference decreased as solid circulation rate increased. Temperature difference decreased as solid circulation rate through the fluidized bed heat exchanger increased. Effect of each variables on temperature profile and performance can be determined and these results will be helpful to determine operating range of each variable.

바닥복사 난방시스템의 밸브구동 특성을 고려한 실내 열환경 성능 개선 연구 (A Study on the Improvement of Indoor Thermal Performance of Floor Radiant Heating System Considering Valve Operation Characteristics)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.36-45
    • /
    • 2021
  • In this study, to improve the indoor thermal environment of the radiant floor heating system, a study was conducted on the temperature change characteristics and energy consumption according to the change of the indoor air set temperature, the supply hot water temperature and the outdoor temperature. As for the control method, the on/off control and the thermal difference proportional control method proposed through previous studies were applied. In addition, in consideration of field applicability, numerical analysis was performed for the case where the indoor air temperature sensor was affected by the wall temperature. As a result, it was found that the temperature difference proportional control method is more effective for thermal comfort and energy saving than on/off control.

Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구 (A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent)

  • 유호천;이영아
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.

바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구 (Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

인체 전력에너지 수확의류 개발을 위한 의복내 온도 측정의 기초적 고찰 (A study on the temperature inside clothing as fundamental data for development of the heat energy harvesting clothing)

  • 양진희;조현승;박선형;이주현
    • 감성과학
    • /
    • 제16권1호
    • /
    • pp.125-132
    • /
    • 2013
  • 에너지 위기의식이 급격히 고조되고 지속 가능한 친환경 에너지원이 이슈화되면서 휴대용 전자기기 산업의 발전은 전원을 공급하기 위한 새로운 에너지원을 요구하고 있으며, 이러한 점에서 언제 어디서나 전력 수확을 가능하게 하는 인체 전력에너지 수확 시스템의 연구가 요청된다. 인체 에너지를 수확하는 방식의 하나인 열전은 인체와 주위 환경간의 온도차이로부터 에너지를 수확하는 방식으로, 본 연구에서는 열전수확에 적합한 의복의 구조와 소재를 탐색하여 인체 전력에너지 수확의류를 위한 기초적 지침을 마련하고자 하였다. 이를 위해 의복의 폐쇄부 구조에 따른 환경 온도와 의복내 온도 간의 차이를 분석하고, 의복의 소재에 따른 환경 온도와 의복내 온도 간의 차이를 도출하였다. 분석 결과, 의복구조에 따른 의복내 온도에 있어서는 인체 부위에 따른 차별화된 결과를 얻을 수 있었는데, 가슴과 등 부위에서는 '폐쇄부 유'의 의복구조인 경우가 '폐쇄부 무' 의복구조에 비하여 의복내 온도가 더 높은 것으로 나타났고, 팔 부위에서 다리 부위로 갈수록 '폐쇄부 유'와 '폐쇄부 무'의 의복구조에 따른 의복내 온도의 차이가 줄어들었다. 한편, 의복소재에 따른 환경 온도와 의복내 온도 간의 차이를 분석한 결과, 두 소재 중 하나의 소재가 일관성 있게 더 높은 온도를 보이지는 않았으며, 인체 부위별로 차이를 보였다. 이러한 의복구조와 소재에 따른 환경 온도와 의복내 온도 간의 차이 결과를 토대로, 인체 전력에너지 수확의류를 위한 지침을 도출하였다.

  • PDF

건물의 침기부하 절감을 위한 에너지셔터에 관한 연구 (A Study on Energy Shutters to Reduce Infiltration Load of Buildings)

  • 고광수;박윤철
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.1-7
    • /
    • 2023
  • In this study, in order to reduce the amount of infiltration generated from windows among the heat loss generated in the building, energy shutters were installed on the windows to conduct experiments on the change in internal temperature and amount of infiltration due to the pressure difference between the environmental chamber and the pressure box. As a result of the experiment, when the pressure difference was 0Pa, the initial temperature of the pressure box of window was higher than that of the pressure box of the energy shutter, but when the pressure difference occurred, the internal temperature of the pressure box of the energy shutter was higher. In addition, the amount of infiltration of the energy shutter was lower than that of the windows in all experimental conditions, and it was concluded that the reduction rate of the infiltration load (of the energy shutters) could be reduced by 53.3% compared to that of the windows.