• Title/Summary/Keyword: Temperature Difference Energy

Search Result 1,101, Processing Time 0.025 seconds

Impacts of Different Urban Surfaces on Summer Thermal Performance

  • Jo, Hyun-Kil;Wu, Qian
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.819-826
    • /
    • 2015
  • This study measured temperatures and albedos of urban surfaces for different colors and materials during summer, and calculated the energy budget over different urban surfaces to find out the thermal performance affecting the heat built-up. The study selected six surface colors and 13 materials common in urban landscape. Their surface temperatures (Ts) and albedos were measured at a given time interval in the daytime from June to August. Average Ts over summer season for asphalt-colored brick was $4.0^{\circ}C$ higher than that for light red-colored one and $9.7^{\circ}C$ higher than that for white-colored one. The Ts for artificial surface materials of asphalt paving, brown brick wall, and green concrete wall was $6.0^{\circ}C$ higher than that for natural and semi-natural ones of grass, grassy block, and planted concrete wall. There was the greatest difference of $16.3^{\circ}C$ at midafternoon in the Ts between asphalt paving and planted concrete wall. Average albedo over summer season of surface materials ranged from 0.08 for asphalt paving to 0.67 for white concrete wall. This difference in the albedo was associated with a maximum of $15.7^{\circ}C$ difference at midafternoon in the Ts. Increasing the albedo by 0.1 (from 0.22 to 0.32) reduced the Ts by about $1.3^{\circ}C$. Average storage heat at midday by natural and semi-natural surfaces of grass and grassy block was about 10% lower than that by artificial ones of asphalt, light-red brick, and concrete. Reflected radiation, which ultimately contributes to heating the urban atmosphere, was 3.7 times greater for light-red brick and concrete surfaces than for asphalt surface. Thus, surfaces with in-between tone and color are more effective than dark- or white-colored ones, and natural or semi-natural surfaces are much greater than artificial ones in improving the urban thermal environment. This study provides new information on correlation between Ts and air temperature, relationship between albedo and Ts, and the energy budget.

The Study on the Thermal Comfort of Rural Housing in Chung-nam area (충남지역 농촌 주거용 건물의 열쾌적성능에 관한 연구)

  • Park, Jae-Sang;Yoo, Jong-Ho;Park, Jae-Wan;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.202-207
    • /
    • 2011
  • This study has measured indoor temperature and relative humidity and evaluated it for one year by selecting Chungnam's rural areas for improving indoor environment of rural housing in the circumstance that the environment of housing is poor due to deterioration of rural housing. As a result of its evaluation, the indoor temperature difference by household appeared to be more than $13^{\circ}C$, and it was measured that the indoor temperature was mostly low. A difference of more than 40% in case of relative humidity occurred, so the difference of the indoor environment by household was clear. In case of the thermal comfort zone, the number of households that are distributed to more than 50% of a thermal comfort criterion in the winter was only 3 households, rather than the summer.

  • PDF

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Effect of heat pump performance improvement by use of thermal tank with temperature seperation plate (격판분리 축열조의 히트펌프 성능개선 효과)

  • Moon, Jongpil;Lee, Sunghyoun;Kwon, Jinkyung;Kang, YounKoo;Lee, Sujang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.80.1-80.1
    • /
    • 2011
  • This study was carried out in order to estimate the effect of heat pump performance by use of thermal tank with 3 seperation plates which were able to divide thermal tank into 3 chambers that have different temperatures levels. For testing the effect of developed thermal tank which was installed for supplying the heat to the paprika greenhouse in Jinju city. The volume of thermal storage tank was designed for $110m^3$ which was able to cover 30% of heating capacity. The temperature difference was 3 degree Celcius between high temperature and low temperature when only heating circulation was made from heat pump to thermal tank. but 5.5 degree Celcius difference was made when heating circulation of heat pump to thermal thank and hot water supplying circulation of thermal tank to greenhouse was done simultaneously. As a result of this study showed that COP of heat pump was increased by 15% or more than that of using normal thermal tank because heat pump was able to take 3 ~ 5 degree Celcius lower thermal thank water constantly.

  • PDF

An Experimental Study of Verification for PEMFC's 1-Dimensional Simulation (PEMFC 1차원 시뮬레이션 검증을 위한 실험적 연구)

  • Moon, Cheor-Eon;Ahn, Seong-Yool;Yang, Jang-Sik;Choi, Gyung-Min;Kim, Duck-Jool
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.191-195
    • /
    • 2007
  • In this study, we estimated the performance of PEMFC's unit cell as changing operating temperature in different inlet humidity condition at cathode side but anode dry, and tried to match experimental results with 1-dimensional simulation. We used $Nafion^{\circledR}112$ membrane and a self-manufactured PEMFC with active area of $25cm^{2}$ was used in this study. The range of operating temperature was $40{\sim}70^{\circ}C$ and oxygen through bubbled humidity chamber was supplied $0{\sim}80$% humidity condition as changing water temperature in humidity chamber. For figuring out governing equations, represent water contents in electrolyte membrane, the linear forward difference method was applied about time progress and quadratic central difference method was used about space progress. It was assumed that pressure terms were linearly changed due to thin electrolyte membrane. In low operating temperature condition, $40{\sim}60^{\circ}C$, increasing temperature rarely effected cell performance but we can see performance drop at $70^{\circ}C$. By modifying Henrry's constant and/or diffusion coefficient, the modified one-dimensional model was accomplished for calculation.

  • PDF

Feasibility Study on Cold Water Pipe Diameter by Friction Loss and Energy Conversion on OTEC (해양온도차 발전을 위한 심층수 파이프 직경에 따른 에너지 손실량 검토)

  • Jung, Hoon;Heo, Gyunyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.170-170
    • /
    • 2010
  • The energy conversion from the temperature difference between hot and cold source like ocean thermal energy conversion (OTEC), requires a long and large-diameter pipe (about 1000 to 10,000 meters long) to reach the deep water. The pipe diameter ranges from 2.8 meter for proposed early test systems, to 5 meter for large, commercial power generation systems. The pipe must be designed to resist collapsing pressures produced by water temperature and density differences, and the reduced pressure required to induce flow up the pipe. Other design considerations include the external-drag effect on the pipe due to ocean currents, and the wave-induced motions of the platform to which the pipe is attached. Various approaches to the pipe construction have been proposed, including aluminum, steel, concrete, and fiberglass. More recently, a flexible pipe construction involving the use of fiberglass reinforced plastic has been proposed. This report presents the results of a scaled fixed cold water pipe (CWP) model test program performed by EES(Engineering Equation Solver) to demonstrate the feasibility of this pipe approach.

  • PDF

Development of a Virtual Frisch-Grid CZT Detector Based on the Array Structure

  • Kim, Younghak;Lee, Wonho
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.1
    • /
    • pp.35-44
    • /
    • 2020
  • Background: Cadmium zinc telluride (CZT) is a promising material because of a high detection efficiency, good energy resolution, and operability at room temperature. However, the cost of CZT dramatically increases as its size increases. In this study, to achieve a large effective volume with relatively low cost, an array structure comprised of individual virtual Frisch-grid CZT detectors was proposed. Materials and Methods: The prototype consisted of 2 × 2 CZTs, a holder, anode and cathode printed circuit boards (PCBs), and an application-specific integrated circuit (ASIC). CZTs were used and the non-contacting shielding electrode method was applied for virtual Frisch-grid effect. An ASIC was used, and the holder and the PCBs were fabricated. In the current system, because the CZTs formed a common cathode, a total of 5 channels were assigned for data processing. Results and Discussion: An experiment using 137Cs at room temperature was conducted for 10 minutes. Energy and timing information was acquired and the depth of interaction was calculated by the timing difference between the signals of both electrodes. Based on obtained three-dimensional position information, the energy correction was carried out, and as a result the energy spectra showed the improvements. In addition, a Compton image was reconstructed using the iterative method. Conclusion: The virtual Frisch-grid CZT detector based on the array structure was developed and the energy spectra and the Compton image were successfully acquired.

A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case (ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.383-391
    • /
    • 2020
  • Purpose: To identify internal self ignition and ignition caused by external flames in energy storage rooms, and to analyze the difference between ignition due to overheating and ignition caused by external heat sources. Method: membrane melting point measurement, battery external hydrothermal experiment, battery overcharge experiment, comparative analysis of electrode plate during combustion by overcharge and external heat, overcharge combustion characteristics, external hydrothermal fire combustion characteristics, 3.4 (electrode plate comparison) / 3.5 (overcharge) /3.6 (external sequence) analysis experiment. Result: Since the temperature difference was very different depending on the position of the sensor until the fire occurred, it is judged that two temperature sensors per module are not enough to prevent the fire through temperature control in advance. Conclusion: The short circuit acts as an ignition source and ignites the mixed gas, causing a gas explosion. The electrode breaks finely due to the explosion pressure, and the powder-like lithium oxide is sparked like a firecracker by the flame reaction.

A Study on the Antibacterial Effects of Pulsed Nd: YAG Laser Irradiation to Streptococcus Mutans (Pulsed Nd : YAG Laser 조사의 Streptococcus mutans에 대한 효과)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 1997
  • In order to investigate the antibacterial effects of pulsed Nd:YAG Laser concerning to Streptococcus mutans, Streptococcus mutans was cultured and standardized and plated in 96 well plates. After that, black dye and chlorhexidine were applied and pulsed Nd:YAG Laser was irradiated to plates. Experimental groups which was applied with black dye and chlorhexidine were divided into 5 groups by concentration. And experimental groups and control group were subdivided as unlased and lased of 20, 40, and 60J. After laser irradiation, All groups were plated in agar plates and incubated for 18 hours. Bacterial colonies were counted and analysed comparitively, and the temperature of culture medium was measured on every laser irradiation. The results were obtained as follows; 1. In case of laser irradiation only, there is no significant reduction in number of Streptococcus mutans by irradiated energy of laser. 2. In case of black dye application, there is no difference by concentration of black dye but there is decrease when applied Laser and black dye simultaneously. 3. When applied chlorhexidine, the number of Streptococcus mutans was decreased according to increase of concentration, but there is no difference by irradiated energy of laser. 4. The temperature of culture medium was increased according to increase of irradiated energy of Laser, and the number of Streptococcus mutans was reduced remarkably just above 50 centigrade and killed above 70 centigrade. As above results, pulsed Nd:YAG Laser has well-absorbing affinity to black dye. And antibacterial effect of pulsed Nd:YAG Laser against Streptococcus mutans is seemed to be due to increase of temperature.

  • PDF

Essence of thermal convection for physical vapor transport of mercurous chloride in regions of high vapor pressures

  • Kim, Geug-Tae;Lee, Kyong-Hwan;Choi, Jeong-Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.6
    • /
    • pp.231-237
    • /
    • 2007
  • For an aspect ratio (transport length-to-width) of 5, Pr=3.34, Le=0.078, Pe=4.16, Cv=1.01, $P_B=50$ Torr, only thermally buoyancy-driven convection ($Gr=4.83{\times}10^5$) is considered in this study in spite of the disparity in the molecular weights of the component A ($Hg_2Cl_2$) and B which would cause thermally and/or solutally buoyancy-driven convection. The crystal growth rate and the maximum velocity vector magnitude are decreased exponentially for $3{\le}Ar{\le}5$, for (1) adiabatic walls and (2) the linear temperature profile, with a fixed source temperature. This is related to the finding that the effects of side walls tend to stabilize convection in the growth reactor. The rate for the linear temperature profiles walls is slightly greater than for the adiabatic walls far varied temperature differences and aspect ratios. With the imposed thermal profile, a fixed source region, both the rate and the maximum velocity vector magnitude increase linearly with increasing the temperature difference for $10{\le}{\Delta}T{\le}50K$.