• Title/Summary/Keyword: Telemetry System

Search Result 347, Processing Time 0.03 seconds

On-line Strain Measurement of Rotating Blade Using Fiber Bragg Grating Sensors and Beam Coupler (광섬유 격자 센서와 빔 커플러를 사용한 회전중인 블레이드의 변형률 측정 방법)

  • Lee, In-Jae;Lee, Jong-Min;Lee, Sang-Bae;Hwang, Yo-Ha
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1172-1178
    • /
    • 2006
  • Measurement of blade strain with sensors directly installed on the blade has one critical issue, how to send the sensor signal to the ground. Strain-gauges have been dominantly used to directly measure stress of a blade and either a slip ring or a telemetry system has to be used to send measured signal to the ground. However, both systems have many inherent problems and sometimes very severe limitations to be practically used. In this paper, new on-line strain monitoring method using. FBG(Fiber Bragg Grating) sensors and a beam coupler is introduced. Measurement of rotor stress using FBG sensors is nothing new, but unlike other system which installs all necessary instruments on the rotor and use telemetry system to send data to the ground, this system makes use of light's unique characteristic - light travels through space. In this new approach, single optical fiber with many FBG sensors is installed on the blade and all other necessary instruments can be installed at ground thereby giving tremendous advantages over slip ring or telemetry system. A reference sensor is also introduced to compensate the beam coupler's transmission loss change due to rotation. The suggested system's good performance is demonstrated with experiments.

Development of E.C.G. Telemetry System Using Digital Communication Method (디지탈 통신방식을 이용한 심전도 텔레메트리 시스템의 개발)

  • 이준하;이상학;신현진;유동수;서희돈;박정연
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.27-34
    • /
    • 1994
  • In this study, we developed E.C.G telemetry system by using a digital communication method. This system is composed of a number of Ambulatory Telemetry System(ATS)'s that use for the same frequency and one center monitoring system(CMS) utilized the personal computer. The purpose of the ATS is, Therefore, to present for acqusition ECG data and transmitting to CMS. The ATS hardware is based on one chip microprocessor (8096) included A/D convert, ECG pre amplifier, ID-decoder, TRX Gateway and FM TRX module. Using the PC can be convinet to processing and deposite for long terms continued patient data.

  • PDF

Time-Varying Parameter Estimation of Passive Telemetry RF Sensor System Using RLS Algorithm (RLS 알고리즘을 이용한 원격 RF 센서 시스템의 시변 파라메타 추정)

  • Kim, Kyung-Yup;Yu, Dong-Gook;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.29-33
    • /
    • 2007
  • In this paper, time-varying parameter of passive telemetry RF sensor system is estimated using RLS(Rescursive $\leq$* Square) algorithm. In order to overcome the problems such as power limits and complication that general RF sensor system including IC chip has, the principle of inductive coupling is applied to model sensor system The model parameter is rearranged for applying RLS algorithm based on mathematical model to the derived model using inductive coupling principle. Time variant parameter of rearranged model is estimated using forgetting factor, and in case measured data is contaminated by noise and modelling error, the performance of RLS algorithm characterized by the convergence of squared error sum is verified by simulation.

  • PDF

On-line Gamma Monitoring System for Environmental Radiation Measurement around KAERI-site (KAERI 부지 주변의 환경선량 측정을 위한 온라인 감마선량 감시시스템)

  • Lee, Chang-Woo;Park, Doo-Won;Lee, Won-Yun;Choi, Yong-Ho;Hong, Kwang-Hee;Kim, Sam-Rang;Lee, Hyun-Duk;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.147-156
    • /
    • 1994
  • On-line gamma monitoring system around KAERI-site was set up to monitor the radiation fluctuations in environment. Data on gamma exposure rates measured by the ionication chamber in the monitoring posts are transmitted to a computer of central control station with. radio telemetry transmission modem and monitored in real time. Radio telemetry transmission system is economical and reliable on handling and storing of data. This monitroing system can triger an early warning system in the event of abnormal radiation levels.

  • PDF

A VLSI Architecture Design of CDMA/TDMA Modem Chipsets for Wireless Telemetry Systems (CDMA/TDMA 기반 무선 원격계측 시스템용 모뎀의 VLSI 구조 설계)

  • 이원재;이성주;이서구;정석호;김재석
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.5
    • /
    • pp.107-114
    • /
    • 2004
  • In this paper, we present the architecture design of CDMA/TDMA modem chipset for wireless telemetry system. The wireless telemetry system a measuring data collecting system from many RTs(Remote Terminal) installed at the specific area using wireless communication technology. It consists of CU single CU (Central Unit) for collecting data and a large amount of RTs for transmitting the measuring data. We propose the hardware architecture of the modem for RT and CU. We also design those modem using Verilog HDL and synthesis them using Synopsys$^{TM}$ CAD tool. The modem of RT is implemented with 27K gates and that of CU is implemented around 220k gates using 0.6${\mu}{\textrm}{m}$ CMOS standard cell. The proposed system is implemented and tested using Altera$^{TM}$ FPGA.PGA.

Mass Memory Operation for Telemetry Processing of LEO Satellite (저궤도위성 원격측정 데이터 처리를 위한 대용량 메모리 운용)

  • Chae, Dong-Seok;Yang, Seung-Eun;Cheon, Yee-Jin
    • Aerospace Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • Because the contact time between satellite and ground station is very limited in LEO (Low Earth Orbit) satellite, all telemetry data generated on spacecraft bus are stored in a mass memory and downlinked to the ground together with real time data during the contact time. The mass memory is initialized in the first system initialization phase and the page status of each memory block is generated step by step. After the completion of the system initialization, the telemetry data are continuously stored and the stored data are played back to the ground by command. And the memory scrubbing is periodically performed for correction of single bit error which can be generated on harsh space environment. This paper introduces the mass memory operation method for telemetry processing of LEO satellite. It includes a general mass memory data structure, the methods of mass memory initialization, scrubbing, data storage and downlink, and mass memory management of primary and redundant mass memory.

Telemetry capsule for pressure monitoring in the gastrointestinal tract (소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현)

  • Yoon, Ki-Won;Woo, Sang-Hyo;Lee, Jyung-Hyun;Moon, Yeon-Kwan;Park, Hee-Joon;Won, Chul-Ho;Kim, Byung-Kyu;Choi, Hyun-Chul;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.

Implementation of LonWorks System for Remote Control and Telemetry Using Web Browser (Web browser를 활용한 원격제어 및 원격검침 LonWorks 시스템 구축에 관한 연구)

  • 홍원표;임구현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.51-57
    • /
    • 2000
  • This paper proposes the new concept & design method and implementation of LonWorks network system for remote monitoring & lighting dimming control and telemetry using Web network. The Experimental LonWorks network system for telemetry & remote monitoring and control are designed and fabricated. As a result, it is verified that LonWorks is open, inteoperable, reliable network system from the experimental results, especially, it seamlessly links the data and control networks, allowing the IP(internet) network to be treated as an extension of the LonWorks networks, and vice versa.

  • PDF

A Study on Shaft Alignment of the Rotating Machinery by Using Strain Gages (스트레인게이지를 이용한 회전체의 축정렬 연구)

  • Kim, Koung-Suk;Jang, Wan-Shik;Na, Sang-Soo;Jung, Hyun-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.126-132
    • /
    • 2002
  • Misaligned shafts of the rotating machinery have caused noise, vibration. bearing failures, and stress concentration of coupling parts which decrease the efficiency and life of shaft systems. Therefore the proper shaft alignment of those system should be monitored continuously in dynamic condition. To solve these problems under dynamic condition a telemetry system is used. In this study, the condition of the least bending moment which is known by analyzing the structure and stress induced by misalignment is found. After the shaft is aligned by dial gage, a telemetry system with strain gages is installed on shaft. The relationship between bearing displacement and moment of coupling part influenced by misalignment is investigated. The moment derived from two shaft strain at the nearby coupling is measured. The bending strain is measured 5 times for average in static state as well as in dynamic state with 100∼700 rpm.

KSR-III 궤도데이터 취득시스템 개발

  • Lee, Sang-Rae;Lee, Soo-Jin;Kim, Jun-Kyu;Lee, Jae-Deuk
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.133-139
    • /
    • 2003
  • Position and trajectory data in-flight rocket are important informations to determine flight safety of rocket. In general tracking system, radar and transponder are used to acquire position information. Rocket position and trajectory can be determined by RF communication between ground station and in-flight rocket, and antenna position date. In this paper, it explains the ranging system which is low resolution rather than radar system but system configuration is simple. Therefore this system is useful for experimental flight vehicle.

  • PDF