• Title/Summary/Keyword: Techno Park

Search Result 765, Processing Time 0.044 seconds

Development of the wooden window design implementing D.I.Y. modular system (D.I.Y. Modular 방식을 도입한 목재 창 디자인 개발)

  • Kim, Jin-Young;Kim, Do-Yeon;Roh, Yang-Mi;Park, Hyo-Mi
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.401-404
    • /
    • 2004
  • The proposal defines a Do It Yourself system that radically changes the traditional concept of window. it is based on a D.I.Y. system that allows the users to fully customize its windows according to his needs, combining a wood frame with different elements. At the same time, it is preserving the basic function of light and ventilation and defining a new aesthetic code. Despite the restriction of size and shape, the user can choose among many different elements to increase the space efficiency he needs and to give a more enjoyable perspective to the window both in and out door. Also, All the elements are standard and they can be mass-produced according to specific market needs. Therefore, the window of the future will not be just a thin membrane in between the inside and the outside, but it will also play an important "identification role. According to each individual pick, these new windows will help to give identify to anonymous metropolitan areas and to the people living within them.

  • PDF

Research of the Performance Improvement of a Light Shelf Depending on the Diffusion Film Installation Position (확산필름 부착 위치에 따른 광선반 성능개선 연구)

  • Park, Eunsu;Lee, Heangwoo;Song, Seonkjae;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.91-97
    • /
    • 2017
  • Purpose: Various studies on a light shelf are in progress, but it has the problem of glare occurrence. The present study suggested a diffusion film as the method for resolving the glare problem, and aimed to establish light shelf-related basic data by conducting the performance evaluation of a light shelf depending on the installation position of the diffusion film. Method: To carry out the light shelf performance evaluation depending on the diffusion film installation position, three cases were established: no diffusion film installation (Case 1), diffusion film installation on the reflector (Case 2), and diffusion film installation on the upper glass surface of the window for light shelf installation (Case 3); and the energy reduction performance, luminance, and luminance contrast were analyzed based on a testbed. Result: The conclusions of this study are as follows. 1) When the diffusion film was applied, the amount of light introduced through the light shelf decreased, and the average indoor illumination decreased accordingly. 2) For Case 3, the lighting energy reduction performance was identical to the lighting energy reduction efficiency of the existing light shelf; and for Case 2, it was found to be inappropriate as the lighting energy consumption increased compared to that of the existing light shelf. 3) The analysis of the glare for the cases established in this study showed that the luminance contrast was low for Case 3, and thus the glare problem could be minimized. 4) The specific angle of the light shelf could induce the glare problem by increasing the luminance depending on the external condition. 5) Based on the aforementioned contents, the installation position of the diffusion film for improving the lighting performance and glare problem of the light shelf was found to be the upper glass surface of the window for light shelf installation.

A Study on the Suggestion of a Lighting Control System Applying General Illumination and Technology of User and Location Awareness (전반조명 기반 사용자 및 위치인식기술 적용 조명제어 시스템 제안 연구)

  • Park, Juil;Lee, Haengwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.527-536
    • /
    • 2015
  • Studies for the reduction of lighting energy have been done using technologies such as user and location awareness. However, the focus of current research on location-based lighting control has been on energy reduction, which can lead to other issues including an imbalance in indoor illumination. This study proposes a lighting control system applying general illumination and technology for user and location awareness. The proposed lighting control system reduced lighting energy by 72.1%, 66.5% and 62.3% for 1, 2 and 3 users, respectively, compared to the On/Off lighting control system. This lighting control system causes an increase in lighting energy of 35.8% and 10.9% for 1 and 2 users compared to the lighting control system with user and location awareness, while a reduction of 9.4% was seen for 3 users. This means that the proposed system provides more effective energy reduction for a room with multiple occupants as it is based on the general lighting control scheme. The lighting control system applying general illumination and technology of user and location awareness improved the uniformity factor by 32.0%, 39.4% and 33.4% for 1, 2 and 3 users, respectively.

Methane Gas Sensing Properties of the Zinc Oxide Nanowhisker-derived Gas Sensor

  • Moon, Hyung-Sin;Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • A low power methane gas sensor with microheater was fabricated by silicon bulk micromachining technology. In order to heat up the sensing layer to operating temperature, a platinum (Pt) micro heater was embedded in the gas sensor. The line width and gap of the microheater was 20 ${\mu}m$ and 4.5 ${\mu}m$, respectively. Zinc oxide (ZnO) nanowhisker arrays were grown on a sensor from a ZnO seed layer using a hydrothermal method. A 200 ml aqueous solution of 0.1 mol zinc nitrate hexahydrate, 0.1 mol hexamethylenetetramine, and 0.02 mol polyethylenimine was used for growing ZnO nanowhiskers. Temperature distribution of the sensor was analyzed by infrared thermal camera. The optimum temperature for highest sensitivity was found to be $250^{\circ}C$ although relatively high (64%) sensitivity was obtained even at as low a temperature as $150^{\circ}C$. The power consumption was 72 mW at $250^{\circ}C$, and only 25 mW at $150^{\circ}C$.

The Study to Find Causes for Measuring Differences of Hydrogen Fillings in Hydrogen Refueling Station (수소충전소의 연료 계량 방법에 따른 계량 오차가 발생하는 원인 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;CHUNG, JIN BAE;HONG, SUK JIN
    • Journal of Hydrogen and New Energy
    • /
    • v.29 no.1
    • /
    • pp.32-40
    • /
    • 2018
  • There has been an measuring errors between state of charge (SOC; kg) value and mass flow meter (MFM) value in dispenser for hydrogen refueling station. Finally, we observed average 15.5% weight difference between these two values and the MFM readings show a 15.5% higher readout of the SOC readings. Each car was charged with average 2.66 kg of hydrogen fuel during this period. In the initial charging of the day shows less measuring value than the final charging with the maximum 0.038 kg times number of filling. There is no effects of atmosphere temperature change for the hydrogen filled weight during one full year such as January's cold winters and August's hot summers.

A Study on the Variation of Unit Price of Hydrogen Fuel by Difference of Fuel Measuring Method (수소 충전소 연료계량방법의 차이에서 발생하는 연료단가의 상이점에 대한 고찰)

  • LEE, TAECK HONG;KANG, BYOUNG WOO;LEE, EUN WOUNG;BAE, CHUNG JIN
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.3
    • /
    • pp.279-286
    • /
    • 2017
  • Korea government decides to build one hundred hydrogen refueling stations (HRS) until 2020 and tries to disseminate HRS and boosts HRS market in korea. Naepo HRS in chungnam province has been operated for last one full year of 2016 and recorded 2,520 times full charge for the hydrogen fuel cell powered vehicles and total 6,016 kg hydrogen fueling for the 25 units of hydrogen fuel cell powered vehicles. Raw fuel of hydrogen from tube trailer measured by pressure, converting into weight of hydrogen and shows 19.6% surplus with final charged weight by dispenser. This result is caused measuring errors. Measured charged errors between dispenser and Mass flow meter was determined 13.13%.

A Study on the Detergency and Functionality of Laminating Finished Fabrics for Outdoor Wear by Repeated Washing (아웃도어용 라미네이팅 가공 직물의 반복세척에 의한 세척성 및 기능성 연구)

  • Hyun, Su Jung;Lee, Jeong Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.3
    • /
    • pp.527-536
    • /
    • 2017
  • This study investigated the detergency and functionality of laminating finished fabrics for outdoor wear based on repeated washing. Laminating finished fabrics were selected as the main fabrics for outdoor wear and used as test fabrics. The effects of outdoor exclusive detergent and normal neutral detergent were examined according to washing time, temperature, rpm and detergent concentration based on the use of a Terg-O-Tometer. Re-soiling of the test fabrics was measured by Florio-Mersereau. Permeability, water repellency, water resistance and absorbency were estimated to measure improvements and effects in regards to outdoor exclusive detergent in optimal washing conditions. The detergent effect of outdoor exclusive detergent was superior compared to normal neutral detergent. Re-soiling was lower with exclusive outdoor detergent than with normal neutral detergent. The measurement of functionality for laminating finished fabrics before and after washing indicated that functionality was decreased with repeated washing.