• 제목/요약/키워드: Tear evaluation

검색결과 129건 처리시간 0.323초

A Study for Health Hazard Evaluation of Methylene Chloride Evaporated from the Tear Gas Mixture

  • Park, Seung-Hyun;Chung, Eun-Kyo;Yi, Gwang-Yong;Chung, Kwang-Jae;Shin, Jung-Ah;Lee, In-Seop
    • Safety and Health at Work
    • /
    • 제1권1호
    • /
    • pp.98-101
    • /
    • 2010
  • This study explored the health hazard of those exposed to methylene chloride by assessing its atmospheric concentration when a tear gas mixture was aerially dispersed. The concentration of methylene chloride ranged from 311.1-980.3 ppm (geometric mean, 555.8 ppm), 30 seconds after the dispersion started. However, the concentration fell rapidly to below 10 ppm after dispersion was completed. The concentration during the dispersion did not surpass the National Institute for Occupational Safety and Health 'immediately dangerous to life or health' value of 2,300 ppm, but did exceed the American Conference of Governmental Industrial Hygienists excursion limit of 250 ppm. Since methylene chloride is highly volatile (vapor pressure, 349 mmHg at $20^{\circ}C$), the post-dispersion atmospheric concentration can rise instantaneously. Moreover, the o-chlorobenzylidenemalononitrile formulation of tear gas (CS gas) is an acute upper respiratory tract irritant. Therefore, tear gas mixtures should be handled with delicate care.

회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도 (Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear)

  • 염재광;신용운;박신승
    • 대한정형외과 초음파학회지
    • /
    • 제2권2호
    • /
    • pp.62-67
    • /
    • 2009
  • 목적: 회전근 개 파열이 있는 환자들에서 3차원 초음파 검사를 시행할 때 생리식염수 20 ml를 견관절강 내에 주사 하기 전과 후의 파열 길이 측정과 수술시 측정과의 차이를 비교 분석하여 초음파 검사시 생리식염수의 관절내 주사가 파열의 길이 측정에 더 유용한 방법인지 확인하고자 하였다. 대상 및 방법: 2007년 8월부터 2008년 9월까지 회전근 개 파열을 진단받고 수술 받은 환자 14명에 대하여 수술 전 3차원 초음파를 이용하여 측정한 회전근 개 파열의 크기와 실제 수술 중에 측정한 파열의 크기를 비교 분석하였다. 3차원 초음파를 이용한 회전근 개 파열의 측정은 관절강 내에 20 ml의 생리식염수를 주사 하기 전, 후로 파열된 회전근 개의 너비와 내측으로의 이동 정도를 측정하였으며, 관절경 수술시에는 Kirschner 강선을 척수 바늘에 통과시키는 방법으로 파열의 길이를 측정하였고 개방적 수술시에는 자를 가지고 직접 측정하였다. 결과: 3차원 초음파 검사시 생리식염수를 주사하기 전 측정한 크기와 실제 파열된 크기를 비교하였을 때 파열의 너비의 차이는 실제 크기보다 평균 8 mm 작게 측정되었고 내측으로의 이동 정도는 평균 1.9 mm 작게 측정되었다. 생리식염수 주사 후에 측정한 결과는 초음파 검사에서 실제 크기보다 평균 4.1 mm 작게 측정되고, 내측으로의 이동의 정도는 평균 1.6 mm 크게 측정되었다. 결론: 3차원 초음파를 이용한 회전근 개 파열의 진단에서 보다 정확한 크기를 측정하기 위하여 관절강 내에 생리 식염수를 주사한 후 검사하면 보다 정확하고 실제 크기와 유사한 측정이 가능할 것으로 사료된다.

  • PDF

공기 주입과 동시에 시행한 견봉하 관절경 술식을 이용한 회전근개 파열의 정도 평가 (Bursoscopic Evaluation for Degree of the Rotator Cuff Tear with Air Infusion Method)

  • 문영래;손홍문;김남형
    • 대한관절경학회지
    • /
    • 제6권2호
    • /
    • pp.126-130
    • /
    • 2002
  • 목적 : 견봉하 점액낭에 가려져 부분층 파열로 여겼던 회전근개 전층 파열을 견관절 내 공기 주입 방식을 사용한 견봉하 점액낭 관절경적 관찰로 효과적인 진단의 가능 여부를 알아 보고자 하였다. 대상 및 방법 : 65예 중 견관절 관절경상 회전근 개 부분층 파열인 18예를 제 1군으로, 전층 파열로서 봉합을 시행 한 37예를 제 2군으로 나누어 견관절에 $50\~100ml$의 공기주입으로 확장을 시킴과 동시에 견봉하 관절내로 누출 되는 공기 방울을 관찰하였다. 결과 : 제 1군 중 3예에서 공기 누출을 보고 전층 파열임을 확인할 수 있었으며, 제 2군 중 2예에서는 다량의 공기 누출 부위가 발견되어 불완전한 봉합임을 확인하고 추가 봉합을 시행 할 수 있었다. 결론 : 공기 주입 방식은 회전근 개 부분층 파열과 전층 파열을 감별하고, 비후되고 유착된 점액낭에 가려져 있는 전층 파열을 발견할 수 있으며, 술 후 봉합 부위의 평가에 유용한 방법으로 사료된다.

  • PDF

Al-Zn-Mg-Cu계 알루미늄 합금의 열간 균열 특성에 미치는 합금조성의 영향 (The Influence of Alloy Composition on the Hot Tear Susceptibility of the Al-Zn-Mg-Cu Alloy System)

  • 김지훈;조재섭;심우정;임항준
    • 대한금속재료학회지
    • /
    • 제50권9호
    • /
    • pp.669-675
    • /
    • 2012
  • Hot tearing was the most significant casting defect when the castability evaluation of the Al-Zn-Mg-Cu alloy system was conducted. It was related to the solidification range of the alloy. Therefore, the hot tear susceptibility of the AA7075 alloy, whose solidification range is the widest, was evaluated. The hot tear susceptibility was evaluated by using a mold for a hot tearing test designed to create the condition for the occurrence of hot tear in 8 steps. According to the tearing location and shape, a hot tear susceptibility index (HTS) score was measured. The solidification range of each alloy and hot tear susceptibility was compared and thereafter the microstructure of a near tear defect was observed. As a result, the HTS of the AA7075 alloy was found to be 67. Also, the HTS in relation to a change in Zn, Mg, Cu composition showed a difference of about 6-11% compared to the AA7075 alloy.

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.

회전근 개 파열로 인한 수술 후 처치에 관한 국내 연구 동향 (The Domestic Trends of Treatments on Postoperative Rotator Cuff Tear)

  • 이충희;김연희;오민석
    • 혜화의학회지
    • /
    • 제27권2호
    • /
    • pp.1-10
    • /
    • 2018
  • Objectives : The purpose of this study is to investigate the latest trend of studies on treatments of postoperative rotator cuff tear patients which are published in Korea. Methods : We investigated the studies on the treatments of postoperative rotator cuff tear patients via searching 6(six) Korean web databases(NSDL, RISS, Korean traditional knowledge portal, OASIS, KISTI, KCI). As a result, 16(sixteen) studies were found. We classified the papers by publication date, published journal, method of study, type of treatment, evaluation scale and referencing research ethics. Results : 16(sixteen) papers were published from 2006 to 2017. The papers were published in The journal of Korean shoulder & elbow society, The journal of korean acupuncture & moxibustion medicine, etc. 5(five) randomized controlled trials, 5(five) non-randomized controlled trials, 4(four) case reports and 2(two) Retrospective report have been found. For types of treatment, 6(six) exercise therapies, 3(three) Korean medicine treatments and 7(seven) other treatments have been found. Main evaluation tools were VAS, ROM, NRS and Muscle strength. Conclusions : In this study, we analyzed the latest trend of studies on treatments of postoperative rotator cuff tear patients. Reviewing the international trends of studies on treatments for postoperative rotator cuff tear are essential for the future studies.

극상근 파열에 대한 Empty Can Test의 진단적 가치 - 관절경 소견과 비교 - (Empty Can Test for Diagnosis of Supraspinatus Tear - Compare with Arthroscopic Finding -)

  • 문영래;유재원;김동휘
    • Clinics in Shoulder and Elbow
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2001
  • Object: To determine the sensitivity, specificity, and positive and negative predictive values of an empty can test for diagnosing supraspinatus tendon tear. Methods: We reviewed 146 patients who have shoulder pain with limited active range of motion. We evaluated patients according to empty can test. Sensitivity, specificity, and positive and negative predictive values for supraspinatus test was estimated using arthroscopic evaluation. Results: A hundred and twenty-four of 127 cases with positive empty can test had supraspinatus tendon tear. Of 19 samples with negative empty can test, 15 had no supraspinatus tear. Sensitivity, specificity, and positive and negative predictive values for the empty can test were 97.6%, 83.3%, 97.6%, and 78.9%, respectively. Conclusions: Empty can test was found to have a high sensitivity and good positive predictive value in identifying the tear of rotator cuff tendon. We concluded that empty can test of the shoulder is a reliable diagnostic method which could be used for the diagnosis of rotator cuff tear.

  • PDF

Al-Si-Mg-Cu 합금계의 열간 균열 특성 평가방법에 관한 연구 (Evaluation of Hot Tear Susceptibility of Al-Si-Mg-Cu Alloy System)

  • 손광석;박태은;김진수;강성민;김동규
    • 대한금속재료학회지
    • /
    • 제48권5호
    • /
    • pp.436-444
    • /
    • 2010
  • The hot tear susceptibility of Al alloys was investigated by using a constrained-rod mold designed to quantify 8 types of tear tendency. The severity of the crack was scored by 5 grades on a scale of 0 to 4, with 0 being "no crack formed" and 4 being "complete separation by crack". The Hot Tear Susceptibility index (HTS) which consists of crack type scores and position scores, was proposed to compare the hot tear tendency of Al alloys. A356.0 cast alloy and AA6061 wrought Al alloy showed an HTS value of 27.5 and 53 respectively. The effects of Si, Cu, and Mg content on hot tear tendency were also investigated with a constrained-rod mold. The variation of HTS values with alloying elements represents similar behavior in the variation of the solidification range in a pseudo binary phase diagram.

회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성 (Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear)

  • 염재광;신용운;한정일
    • Clinics in Shoulder and Elbow
    • /
    • 제11권1호
    • /
    • pp.24-28
    • /
    • 2008
  • 목적: 본 연구의 목적은 수술 전 회전근 개 파열에 대한 3차원 초음파 검사의 시행은 파열의 실제 크기를 수술 전 확인하는 데 유용함을 보고하고자 하는 것이다. 대상 및 방법: 자기공명영상 촬영상 회전근 개 완전 파열이 있어 수술을 시행한 환자 중 수술 전 3차원 초음파 검사를 시행하여 파열의 크기를 측정하였고, 수술시 회전근 개의 실제 크기를 측정하여 비교하였다. 이 연구에는 수술 시 회전근 개 완전 파열이 확인된 15예(남자가 7명, 여자가 8명)가 포함되었다. 평균 연령은 55.4세($47{\sim}67$)였으며, 우측 견관절은 13예, 좌측 견관절은 2예였다. 결과: 수술 전 초음파 검사로 측정한 파열의 크기와 실제 수술시 측정한 크기의 차이는 가로 길이는 평균 0.7 mm의 오차를 보였고, 세로 길이는 평균 2.0 mm의 오차를 보였다. 결론: 수술 전 3차원 초음파 검사와 실제 수술시 측정한 회전근 개 파열의 가로 및 세로 크기가 거의 일치함을 보여 수술 전 3차원 초음파 검사는 매우 유용한 검사로 사료된다.

비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰 (Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity)

  • 백승훈;최창혁
    • 대한정형외과 초음파학회지
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2013
  • 목적: 상완골 골절에 대한 비확공성 전향적 금속정 내고정술 시행 후, 초음파을 이용하여 회전근 개 상태 및 영향 인자를 객관적으로 평가하고, 초음파 검사의 유용성을 확인하였다. 대상 및 방법: 상완골 골절로 골수강 내 금속정 내고정술을 시행받고 견관절의 초음파 검사를 시행한 17례를 연구 대상으로 하였다. 평균 연령은 $55.7{\pm}18.6$세였으며, 최초 수술 후 평균 추시 기간은 $43.5{\pm}32.2$개월이었다. 전 례에서 술중 회전근개 상태를 확인하였고, 4례(24%)에서 피부절개 후 회전근 개의 파열이 관찰되어 금속 봉합나사못을 이용하여 단열 봉합술을 시행하였다. 임상적 평가는 visual analogue scale (VAS), 운동범위, Korean Shoulder Scoring System (KSS) 및 American Shoulder and Elbow Society (ASES) 점수를 측정하였다. 회전근개의 상태에 대한 초음파 검사를 시행하였고, 견관절 기능에 영향을 미칠 수 있는 방사선학적 유합 시기, 금속정 근위 첨부 돌출 및 근위 교합 나사의 이동을 평가하였다. 금속정 근위 첨부 돌출에 대해서는 방사선학적 검사와 함께 초음파적 검사도 병행하였다. 결과: 최종 추시시 VAS는 평균 $1.65{\pm}1.84$, 운동 범위는 전방 굴곡 평균 $137.0{\pm}33.5^{\circ}$, 외회전 평균 $43.5{\pm}12.7^{\circ}$, 내회전 평균 $16.4{\pm}2.0^{\circ}$이었다. KSS점수는 평균 $79.6{\pm}20.7$점이었으며, ASES점수는 평균 $83.7{\pm}17.0$점이었다. 방사선학적 평가상 전례에서 골유합을 얻었으며, 골유합 기간은 평균 $3.4{\pm}1.3$개월이었으며, 근위 교합 나사의 이동이 6례(35%) 관찰되었다. 견관절 초음파 검사상 회전근 개는 정상 8례(47%), 굴곡변화 4례(24%) 및 부분파열 5례(29%)가 관찰되었으나 완전파열은 관찰되지 않았다. 금속정 첨부 돌출은 방사선 검사상 8례(47%), 초음파 검사상 총 11례(65%)에서 관찰되었고, 고령의 환자에서 호발하였다(p=0.038). 회전근 개의 굴곡 변화 및 부분파열은 첨부 돌출과 관련이 있었으나(p=006), 술전 파열의 봉합여부와는 관련이 없었다(p>0.05). 결론: 금속정 삽입술시 회전근 개 손상을 피하기 위하여 금속정 첨부의 연골하골 내 적절한 함입을 요하며, 초음파를 이용한 경과 관찰은 단순 방사선 검사상 파악하기 곤란한 금속정 첨부의 돌출 및 회전근 개 손상을 확인할 수 있는 유용한 진단 및 평가 도구가 될 수 있을 것으로 판단된다.

  • PDF