Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity

비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰

  • Baek, Seung-Hoon (Department of Orthopaedic Surgery, Kyungpook National University, Graduate School of Medicine) ;
  • Choi, Chang-Hyuk (Department of Orthopaedic Surgery, School of Medicine, Catholic University of Daegu)
  • 백승훈 (경북대학교 의학전문대학원 정형외과학교실) ;
  • 최창혁 (대구가톨릭대학교 의과대학 정형외과학교실)
  • Published : 2013.03.28

Abstract

Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

목적: 상완골 골절에 대한 비확공성 전향적 금속정 내고정술 시행 후, 초음파을 이용하여 회전근 개 상태 및 영향 인자를 객관적으로 평가하고, 초음파 검사의 유용성을 확인하였다. 대상 및 방법: 상완골 골절로 골수강 내 금속정 내고정술을 시행받고 견관절의 초음파 검사를 시행한 17례를 연구 대상으로 하였다. 평균 연령은 $55.7{\pm}18.6$세였으며, 최초 수술 후 평균 추시 기간은 $43.5{\pm}32.2$개월이었다. 전 례에서 술중 회전근개 상태를 확인하였고, 4례(24%)에서 피부절개 후 회전근 개의 파열이 관찰되어 금속 봉합나사못을 이용하여 단열 봉합술을 시행하였다. 임상적 평가는 visual analogue scale (VAS), 운동범위, Korean Shoulder Scoring System (KSS) 및 American Shoulder and Elbow Society (ASES) 점수를 측정하였다. 회전근개의 상태에 대한 초음파 검사를 시행하였고, 견관절 기능에 영향을 미칠 수 있는 방사선학적 유합 시기, 금속정 근위 첨부 돌출 및 근위 교합 나사의 이동을 평가하였다. 금속정 근위 첨부 돌출에 대해서는 방사선학적 검사와 함께 초음파적 검사도 병행하였다. 결과: 최종 추시시 VAS는 평균 $1.65{\pm}1.84$, 운동 범위는 전방 굴곡 평균 $137.0{\pm}33.5^{\circ}$, 외회전 평균 $43.5{\pm}12.7^{\circ}$, 내회전 평균 $16.4{\pm}2.0^{\circ}$이었다. KSS점수는 평균 $79.6{\pm}20.7$점이었으며, ASES점수는 평균 $83.7{\pm}17.0$점이었다. 방사선학적 평가상 전례에서 골유합을 얻었으며, 골유합 기간은 평균 $3.4{\pm}1.3$개월이었으며, 근위 교합 나사의 이동이 6례(35%) 관찰되었다. 견관절 초음파 검사상 회전근 개는 정상 8례(47%), 굴곡변화 4례(24%) 및 부분파열 5례(29%)가 관찰되었으나 완전파열은 관찰되지 않았다. 금속정 첨부 돌출은 방사선 검사상 8례(47%), 초음파 검사상 총 11례(65%)에서 관찰되었고, 고령의 환자에서 호발하였다(p=0.038). 회전근 개의 굴곡 변화 및 부분파열은 첨부 돌출과 관련이 있었으나(p=006), 술전 파열의 봉합여부와는 관련이 없었다(p>0.05). 결론: 금속정 삽입술시 회전근 개 손상을 피하기 위하여 금속정 첨부의 연골하골 내 적절한 함입을 요하며, 초음파를 이용한 경과 관찰은 단순 방사선 검사상 파악하기 곤란한 금속정 첨부의 돌출 및 회전근 개 손상을 확인할 수 있는 유용한 진단 및 평가 도구가 될 수 있을 것으로 판단된다.

Keywords