• Title/Summary/Keyword: Tear evaluation

Search Result 129, Processing Time 0.027 seconds

A Study for Health Hazard Evaluation of Methylene Chloride Evaporated from the Tear Gas Mixture

  • Park, Seung-Hyun;Chung, Eun-Kyo;Yi, Gwang-Yong;Chung, Kwang-Jae;Shin, Jung-Ah;Lee, In-Seop
    • Safety and Health at Work
    • /
    • v.1 no.1
    • /
    • pp.98-101
    • /
    • 2010
  • This study explored the health hazard of those exposed to methylene chloride by assessing its atmospheric concentration when a tear gas mixture was aerially dispersed. The concentration of methylene chloride ranged from 311.1-980.3 ppm (geometric mean, 555.8 ppm), 30 seconds after the dispersion started. However, the concentration fell rapidly to below 10 ppm after dispersion was completed. The concentration during the dispersion did not surpass the National Institute for Occupational Safety and Health 'immediately dangerous to life or health' value of 2,300 ppm, but did exceed the American Conference of Governmental Industrial Hygienists excursion limit of 250 ppm. Since methylene chloride is highly volatile (vapor pressure, 349 mmHg at $20^{\circ}C$), the post-dispersion atmospheric concentration can rise instantaneously. Moreover, the o-chlorobenzylidenemalononitrile formulation of tear gas (CS gas) is an acute upper respiratory tract irritant. Therefore, tear gas mixtures should be handled with delicate care.

Three Dimensional Ultrasonographic Evaluation with Intra-articular Saline Injection in Rotator Cuff Tear (회전근 개 파열의 수술 전 3차원 초음파 검사에서 관절내 생리식염수 주사 후 검사의 정확도)

  • Yum, Jae-Kwang;Shin, Yong-Woon;Park, Shin-Seung
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.62-67
    • /
    • 2009
  • Purpose: The purpose of this study is to find out the accuracy and usability of the three dimensional ultrasonography in measuring the size of the rotator cuff tear, especially before and after the injection of normal saline into the glenohumeral joint. Materials and Methods: 14 patients of rotator cuff tear who were diagnosed and operated from August 2007 to September 2008 were included in this study and authors compared the size of rotator cuff tear measured with three dimensional ultrasonography with the real size measured intraoperatively. In preoperative ultrasonographic evaluation, horizontal and longitudinal length of rotator cuff tear before and after injection of normal saline intraarticularly. During the arthroscopic operation the size of tear was measured by passing a Kirschner wire through a spinal needle and direct measure was performed in open surgery. Results: The average difference was 8 mm in horizontal and 1.9 mm in longitudinal length of tear without saline injection between ultrasonographic and intraoperative measure. The average difference was 4.1 mm in horizontal and 1.6 mm in longitudinal length of tear after the normal saline injection. Conclusion: In three dimensional ultrasonographic evaluation in rotator cuff tear, intraarticular normal saline injection would produce more accurate results.

  • PDF

Bursoscopic Evaluation for Degree of the Rotator Cuff Tear with Air Infusion Method (공기 주입과 동시에 시행한 견봉하 관절경 술식을 이용한 회전근개 파열의 정도 평가)

  • Moon, Young-Lae;Sohn, Hong-Moon;Kim, Nam-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.126-130
    • /
    • 2002
  • Purpose : To evaluate the diagnostic efficiency of the subacromial bursoscopy with glenohumeral air infusion technique for detection of the full thickness tear which we used to think as a partial thickness tear, because it was hidden by bursal tissue. Materials and methods : We chose 65 cases and divided them into 2 groups. The group I was 18 cases with partial thickness rotator cuff tears on glenohumeral arthroscopic evaluation, and the group 2 was 37 cases with full thickness rotator cuff tears which were repaired. We inflated the glenohumeral Joint with 50-100ml of air and observed air bubble leakage simultaneously on bursoscopy. Results : In group I, we could detect air leakage in 3 cases and found that it was full thickness tear. In group II, 2 cases revealed too much air leakage proved that it was incomplete repair and was in need of additional suture. Conclusion : Air infusion technique is though to be a valuable method in differentiation between the partial and full thickness tear and for evaluation of the security of the repair.

  • PDF

The Influence of Alloy Composition on the Hot Tear Susceptibility of the Al-Zn-Mg-Cu Alloy System (Al-Zn-Mg-Cu계 알루미늄 합금의 열간 균열 특성에 미치는 합금조성의 영향)

  • Kim, Jee-Hun;Jo, Jae-Sub;Sim, Woo-Jeong;Im, Hang-Joon
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.9
    • /
    • pp.669-675
    • /
    • 2012
  • Hot tearing was the most significant casting defect when the castability evaluation of the Al-Zn-Mg-Cu alloy system was conducted. It was related to the solidification range of the alloy. Therefore, the hot tear susceptibility of the AA7075 alloy, whose solidification range is the widest, was evaluated. The hot tear susceptibility was evaluated by using a mold for a hot tearing test designed to create the condition for the occurrence of hot tear in 8 steps. According to the tearing location and shape, a hot tear susceptibility index (HTS) score was measured. The solidification range of each alloy and hot tear susceptibility was compared and thereafter the microstructure of a near tear defect was observed. As a result, the HTS of the AA7075 alloy was found to be 67. Also, the HTS in relation to a change in Zn, Mg, Cu composition showed a difference of about 6-11% compared to the AA7075 alloy.

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.

The Domestic Trends of Treatments on Postoperative Rotator Cuff Tear (회전근 개 파열로 인한 수술 후 처치에 관한 국내 연구 동향)

  • Lee, Chung-Hee;Kim, Yeon-Hee;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.27 no.2
    • /
    • pp.1-10
    • /
    • 2018
  • Objectives : The purpose of this study is to investigate the latest trend of studies on treatments of postoperative rotator cuff tear patients which are published in Korea. Methods : We investigated the studies on the treatments of postoperative rotator cuff tear patients via searching 6(six) Korean web databases(NSDL, RISS, Korean traditional knowledge portal, OASIS, KISTI, KCI). As a result, 16(sixteen) studies were found. We classified the papers by publication date, published journal, method of study, type of treatment, evaluation scale and referencing research ethics. Results : 16(sixteen) papers were published from 2006 to 2017. The papers were published in The journal of Korean shoulder & elbow society, The journal of korean acupuncture & moxibustion medicine, etc. 5(five) randomized controlled trials, 5(five) non-randomized controlled trials, 4(four) case reports and 2(two) Retrospective report have been found. For types of treatment, 6(six) exercise therapies, 3(three) Korean medicine treatments and 7(seven) other treatments have been found. Main evaluation tools were VAS, ROM, NRS and Muscle strength. Conclusions : In this study, we analyzed the latest trend of studies on treatments of postoperative rotator cuff tear patients. Reviewing the international trends of studies on treatments for postoperative rotator cuff tear are essential for the future studies.

Empty Can Test for Diagnosis of Supraspinatus Tear - Compare with Arthroscopic Finding - (극상근 파열에 대한 Empty Can Test의 진단적 가치 - 관절경 소견과 비교 -)

  • Moon Young Lae;You Jea Won;Kim Dong Hui
    • Clinics in Shoulder and Elbow
    • /
    • v.4 no.1
    • /
    • pp.13-16
    • /
    • 2001
  • Object: To determine the sensitivity, specificity, and positive and negative predictive values of an empty can test for diagnosing supraspinatus tendon tear. Methods: We reviewed 146 patients who have shoulder pain with limited active range of motion. We evaluated patients according to empty can test. Sensitivity, specificity, and positive and negative predictive values for supraspinatus test was estimated using arthroscopic evaluation. Results: A hundred and twenty-four of 127 cases with positive empty can test had supraspinatus tendon tear. Of 19 samples with negative empty can test, 15 had no supraspinatus tear. Sensitivity, specificity, and positive and negative predictive values for the empty can test were 97.6%, 83.3%, 97.6%, and 78.9%, respectively. Conclusions: Empty can test was found to have a high sensitivity and good positive predictive value in identifying the tear of rotator cuff tendon. We concluded that empty can test of the shoulder is a reliable diagnostic method which could be used for the diagnosis of rotator cuff tear.

  • PDF

Evaluation of Hot Tear Susceptibility of Al-Si-Mg-Cu Alloy System (Al-Si-Mg-Cu 합금계의 열간 균열 특성 평가방법에 관한 연구)

  • Son, Kwang-Suk;Park, Tae-Eun;Kim, Jin-Su;Kang, Sung-Min;Kim, Donggyu
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.5
    • /
    • pp.436-444
    • /
    • 2010
  • The hot tear susceptibility of Al alloys was investigated by using a constrained-rod mold designed to quantify 8 types of tear tendency. The severity of the crack was scored by 5 grades on a scale of 0 to 4, with 0 being "no crack formed" and 4 being "complete separation by crack". The Hot Tear Susceptibility index (HTS) which consists of crack type scores and position scores, was proposed to compare the hot tear tendency of Al alloys. A356.0 cast alloy and AA6061 wrought Al alloy showed an HTS value of 27.5 and 53 respectively. The effects of Si, Cu, and Mg content on hot tear tendency were also investigated with a constrained-rod mold. The variation of HTS values with alloying elements represents similar behavior in the variation of the solidification range in a pseudo binary phase diagram.

Preoperative Three Dimensional Ultrasonographic Evaluation of the Rotator Cuff Tear (회전근 개 파열에 대한 수술 전 3차원 초음파 검사의 유용성)

  • Yum, Jae-Kwang;Sin, Yong-Woon;Han, Jung-Il
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.24-28
    • /
    • 2008
  • Purpose: We wanted to determine if preoperative three dimensional (3D) ultrasonographic evaluation for rotator cuff tear is useful to measure the real size of a torn rotator cuff for performing an operation Materials and Methods: This study included 15 cases (7 males and 8 female), and these patients were confirmed to have a full thickness tear of the rotator cuff by 3D ultrasonography and the operative findings, as well as on the magnetic resonance imaging (MRI). The average age of the patients was 55.4yrs. Results: The average difference between the 3D ultrasonographic and operative measurements of the full thickness tear of the rotator cuff was 0.7 mm in the transverse length and 2.0 mm in the longitudinal length. Conclusion: The low error between the 3D ultrasonographic and intraoperative measurements of rotator cuff tear shows the usefulness of preoperative 3D ultrasonographic evaluation for rotator cuff tear.

Clinical and Radiographic Outcome of Shoulder Function after Unreamed Antegrade Intramedullary Nailing for Humerus Fracture: Ultrasonographic Evaluation for Rotator Cuff Integrity (비확공성 전향적 상완골 금속정 고정술후 견관절 기능에 대한 임상적 및 방사선학적 평가: 초음파를 이용한 회전근 개 추시관찰)

  • Baek, Seung-Hoon;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Purpose: The purpose is to perform objective evaluation for rotator cuff using ultrasonography and validate factors influencing cuff integrity as well as efficacy of follow-up ultrasonography after unreamed antegrade intramedullary nailing for humerus fracture. Materials and Methods: Seventeen patients with an average age of $55.7{\pm}18.6$ years underwent antegrade intramedullary nailing for humerus fracture and follow-up ultrasonography of shoulder joint. Mean follow-up period was $43.5{\pm}32.2$ months. Intraoperative evaluation for preoperative cuff tear was performed, of which four cuffs were repaired by single row repair technique. Clinical evaluation included visual analogue scale (VAS), range of motion, Korean Shoulder Scoring System (KSS) and American Shoulder and Elbow Society (ASES) score. Ultrasonographic evaluation was performed on cuff integrity and protrusion of proximal nail tip as well. Radiographic evaluation included time to union, protrusion of proximal nail tip and migration of proximal interlocking screw which could affect shoulder joint function. Results: Mean VAS at last follow-up was $1.65{\pm}1.84$ points. Range of motion showed forward flexion of $137.0{\pm}33.5^{\circ}$, external rotation of $43.5{\pm}12.7^{\circ}$ and internal rotation of $16.4{\pm}2.0^{\circ}$ while KSS score and ASES score were $79.6{\pm}20.7$ and $83.7{\pm}17.0$ points, respectively. Bone union was demonstrated in all cases and average time to union was $3.4{\pm}1.3$ months. Migration of proximal interlocking screw was shown in 6 cases (35%). On ultrasonographic evaluation, there were normal in 8 (47%), weaving in 4 (24%), partial tear in 5 cases (29%), but no complete tear. Protrusion of proximal nail tip was demonstrated in 8 cases (47%) on plain radiographs whereas in 11 cases (65%) on ultrasonography and was associated with increasing age (p=0.038). Ultrasonographic weaving and partial tear was associated with protrusion of proximal nail tip (p=006), but not with repair of preoperative tear (p>0.05). Conclusion: Because weaving and partial tear on ultrasonography originated from protrusion of proximal nail tip, careful insertion of nail and meticulous repair of cuff during operation lead to stable fixation with satisfactory recovery of shoulder function follow-up ultrasonography can be a useful tool for evaluating protrusion of nail tip and rotator cuff tear, of which diagnosis is difficult on plain X-ray after antegrade intramedullary nailing for humerus fracture.

  • PDF