• Title/Summary/Keyword: Target therapy

Search Result 1,133, Processing Time 0.042 seconds

The Output Factor of Small Field in Multileaf Collimator of 6 MV Photon Beams (다엽제한기 소조사면의 6 MV 광자선 출력선량계수)

  • Lee, Ho Joon;Choi, Tae-Jin;Oh, Young Kee;Jeun, Kyung Soo;Lee, Yong Hee;Kim, Jin Hee;Kim, Ok Bae;Oh, Se An;Kim, Sung Kyu;Ye, Ji Woon
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • The IMRT is proper implement to get high dose deliver to tumor as its shape and selective approach in radiation therapy. Since the IMRT is performed as modulated the radiation fluence by the MLC created the open shapes and its irradiation time, the dose of segment of radiation field effects on the cumulated portal dose. The accurate output factor of small and step shape of segment is important to improve the determination of deliver tumor dose as it is directly proportional to dose. This experiment performed with the 6 MV photon beam of Clinac Ex(Varian) from $3{\times}3cm^2$ to $0.5{\times}0.5cm^2$ small field size for collimator jaw in MLC free and/or for MLC open field in fixed collimator jaw $10{\times}10cm^2$ using the CC01 ion chamber, SFD diode, diamond detector and X-Omat film dosimetry. As results of normalized to the reference field of $10{\times}10cm^2$ of MLC, the output factor of $3{\times}3cm^2$ showed $0.899{\pm}0.0106$, $0.855{\pm}0.0106$ for $2{\times}2cm^2$, $0.764{\pm}0.0082$ for $1{\times}1cm^2$ and $0.602{\pm}0.0399$ for $0.5{\times}0.5cm^2$. The output factor of MLC open field has shown a maximum 3.8% higher than that of the collimator jaw open field.

Evaluation of the dose distribution in Mapcheck using Enhanced Dynamic Wedge (Enhanced Dynamic Wedge를 사용한 Mapcheck에서의 선량분포 평가)

  • Kang, Su-Man;Jang, Eun-Sun;Lee, Byung-Koo;Jung, Bong-Jae;Shin, Jung-Sub;Park, Cheol-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.343-349
    • /
    • 2012
  • Intensity Modulated Radiotherapy (IMRT) is increasing its use recently due to its benefits of minimizing the dose on surrounding normal organs and being able to target a high dose specifically to the tumor. The study aims to measure and evaluate the dose distribution according to its dynamic changes in Mapcheck. In order to verify the dose distribution by EDW angle($10^{\circ}$,$15^{\circ}$,$20^{\circ}$,$25^{\circ}$,$30^{\circ}$,$45^{\circ}$,$60^{\circ}$), field size (asymmetric field) and depth changes (1.5 cm, 5.0 cm) using IMRT in Clinac ix, a solid phantom was placed on the Mapcheck and 100MU was exposed by 6 MV, 10MV X-ray. Using a 6MV, 10MV energy, the percentage depth dose according to a dynamic changes at a maximum dose depth (1.5 cm) and at 5.0 cm depth showed the value difference of maximum 0.6%, less than 1%, which was calculated by a treatment program device considering the maximum dose depth at the center as 100%, the percentage depth dose was in the range between 2.4% and 7.2%. Also, the maximum value difference of a percentage depth dose was 4.1% in Y2-OUT direction, and 1.7% in Y1-IN direction. When treating a patient using a wedge, it is considered that using an enhanced dynamic wedge is effective to reduce the scattered dose which induces unnecessary dose to the surroundings. In particular, when treating a patient at clinic, a treatment must be performed considering that the wedge dose in a toe direction is higher than the dose in a heel direction.

A Study on Pulmonary Toxic Effect of High-Dose Cisplatin Administered by Isolated Lung Perfusion in Dogs (잡견에서 분리폐관류 방법으로 투여된 고농도 cisplatin의 페독성에 관한 연구)

  • 김관민;한정호;김주현
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.697-706
    • /
    • 2000
  • Background: Isolated lung perfusion(ILP) was developed as a new treatment approach to non-resectable primary or metastatic lung cancer, because of its ability to reduce systemic toxicity while delivering high-dose chemotherapeutic agents to the target organs. This research was planned to evaluate the direct toxic effect of high-dose cisplatin to the lung tissue during isolated lung perfusion. Material and Method: Fifteen mongrel dogs were divided in the perfusate for 40 minutes. The second group was composed of 5 mongrel dogs which underwent ILP with cisplatin 2.5 mg/Kg added to the perfusate for 30 minutes and 10 minutes with washing solution without cisplatin. The third group underwent the same procedure as the second group except cisplatin 5.0 mg/Kg in the perfusate. Activities of serum angiotensin converting enzyme(ACE), tumor necrosis factor-$\alpha$(TNF-$\alpha$), and concentration of serum lactate dehydrogenase(LDH) and blood urea nitrogen/creatinine (BUN/Cr) were analyzed in each groups at the time of pre-perfusion, 1 hour, 1 day, 1 week, and 2 weeks after ILP. Result: Serum ACE activities before and 1 hour, 1 day, 1 week, and 2 weeks after ILP in control group were 45.1$\pm$6.3, 44.6$\pm$9.3, 46.7$\pm$9.5, 50.8$\pm$9.1, 46.1$\pm$4.3 U/L. Those in cisplatin 2.5 and 5.0 mg/Kg groups were 49.4$\pm$12.6, 39.0$\pm$8.6, 42.3$\pm$15.9, 50.0$\pm$2.6, 53.8$\pm$8.3 and 55.5$\pm$12.3, 47.0$\pm$6.3, 45.1$\pm$6.9, 74.8$\pm$19.5, 60.2$\pm$12.0 U/L, respectively. Serum TNF-$\alpha$ activities in each group before and after ILP were 5.0$\pm$1.5 / 7.7$\pm$2.2 / 6.6$\pm$2.5 / 4.3$\pm$1.3 / 5.2$\pm$1.1(control), 8.7$\pm$1.6 / 9.9$\pm$2.2 / 7.9$\pm$1.5 / 6.3$\pm$2.2 / 7.4$\pm$2.4 (cisplatin 2.5 mg/Kg), and 6.9$\pm$0.7 / 8.9$\pm$3.4 / 7.9$\pm$4.0 / 3.3$\pm$0.9 / 5.8$\pm$1.3 pg/ml(cisplatin 5.0 mg/Kg). Mean LDH levels of each group were 225.7 / 271.3 / 328.9 / 350.8 / 255.7(control), 235.7 / 265.7 / 336.0 / 379.5 / 299.2 (cisplatin 2.5 mg/Kg), and 259.6 / 285.2 / 340.6 / 433.4 / 292.4 IU/L(cisplatin 5.0 mg/Kg). So there was no significant difference in serum ACE, TNF-$\alpha$, and LDH activity changes after ILP between the 3 groups. And, there was no significant changes in BUN/Cr in each groups, which was independent of ILP and perfused concentration of cisplatin. In addition, all dogs survived the ILP and there was no significant evidence of pulmonary vascular injury after 2 weeks of ILP with cisplatin. Conclusion: There was no harmful effect of cisplatin to the lund tissue of the mongrel dog up to 5.0 mg/Kg in perfusate. Therefore, it is perceived to be safe and effective to deliver high-dose cisplatin to the lung without pulmonary toxicity and renal damage with ILP.

  • PDF

An Investigation of Glyceollin I's Inhibitory Effect on The Mammalian Adenylyl (글리세올린 I의 아데니닐 고리화 효소 활성 억제 효능과 결합 부위 비교 분석)

  • Kim, Dong-Chan;Kim, Nam Doo;Kim, Sung In;Jang, Chul-Soo;Kweon, Chang Oh;Kim, Byung Weon;Ryu, Jae-Ki;Kim, Hyun-Kyung;Lee, Suk Jun;Lee, Seungho;Kim, Dongjin
    • Journal of Life Science
    • /
    • v.23 no.5
    • /
    • pp.609-615
    • /
    • 2013
  • Glyceollin I has gained attention as a useful therapy for various dermatological diseases. However, the binding property of glyceollin I to the mammalian adenylyl cyclase (hereafter mAC), a critical target enzyme for the down-regulation of skin melanogenesis, has not been fully explored. To clarify the action mechanism between glyceollin I and mAC, we first investigated the molecular docking property of glyceollin I to mAC and compared with that of SQ22,536, a well-known mAC inhibitor, to mAC. Glyceollin I showed superiority by forming three hydrogen bonds with Asp 1018, Trp 1020, and Asn 1025, which exist in the catalytic site of mAC. However, SQ22,536 formed only two hydrogen bonds with Asp 1018 and Asn 1025. Secondly, we confirmed that glyceollin I effectively inhibits the formation of forskolin-induced cAMP and the phosphorylation of PKA from a cell-based assay. Long term treatment with glyceollin I had little effect on the cell viability. The findings of the present study also suggest that glyceollin I may be extended to be used as an effective inhibitor of hyperpigmentation.

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams (에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과)

  • 강위생
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.65-71
    • /
    • 1998
  • The aims are to evaluate the effects of an 1.0 cm acrylic plate and SSD on the dose profile and depth dose distribution of 9 MeV electron beam and to analyse adequacy for using an acrylic plate to reduce energy of electron beams. An acrylic plate of 1.0 cm thickness was used to reduce energy of 9 MeV electron beam to 7 MeV. The plate was put on an electron applicator at 65.4 cm distance from x-ray target. The size of the applicator was 10${\times}$l0cm at 100 cm SSD. For 100cm, l05cm and 110cm SSD, depth dose on beam axis and dose profiles at d$\_$max/ on two principal axes were measured using a 3D water phantom. From depth dose distributions, d$\_$max/, d$\_$85/, d$\_$50/ and R$\_$p/, surface dose, and mean energy and peak energy at surface were compared. From dose profiles flatness, penumbra width and actual field size were compared. For comparison, 9 MeV electron beams were measured. Surface dose of 7 MeV electron beams was changed from 85.5% to 82.2% increasing SSD from 100 cm to 110 cm, and except for dose buildup region, depth dose distributions were independent of SSD. Flatness of 7 MeV ranged from 4.7% to 10.4% increasing SSD, comparing 1.4% to 3.5% for 9 MeV. Penumbra width of 7 MeV ranged from 1.52 cm to 3.03 cm, comparing 1.14 cm to 1.63 cm for 9 MeV. Actual field size increased from 10.75 cm to 12.85 cm with SSD, comparing 10.32 cm to 11.46 cm for 9 MeV. Virtual SSD's of 7 and 9 MeV were respectively 49.8 cm and 88.5cm. In using energy reducer in electron therapy, depth dose distribution were independent of SSD except for buildup region as well as open field. In case of using energy reducer, increasing SSD made flatness to deteriorate more severely, penumbra width more wide, field size to increase more rapidly and virtual SSD more short comparing with original electron beam. In conclusion, it is desirable to use no energy reducer for electron beam, especially for long SSD.

  • PDF

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

A Study on Experimental Construction of Community Garden - A Case Study on Rooftop of SAHA Disabled Welfare House - (커뮤니티 가든 조성을 위한 실험 연구 - 사하 장애인복지관 옥상을 대상으로 -)

  • Kim, Seung-Hwan;Yoon, Sung-Yung;Cha, Min-Jun;Yoo, yeon-seo;Cho, Ji-Young;Kim, Yoon-Sun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.2
    • /
    • pp.24-37
    • /
    • 2012
  • In this study, Community Garden of various national and international practices trends to an advanced research, the concept of community garden participated with a group operation out of initiative to produce safety food while securing space for the community, ensuring the area that has gone through a new form of active secure urban green space plan, urban renewal movement was defined as the mean. Furthermore, for the purpose of improving the poor welfare environment by attempting to experimentally make a community garden of a disabled welfare house rooftop and how to target its planning and construction process, partnership involvement, business processes have been investigated, such as cost sharing. The whole process including a budget for development of this case was conducted by the Busan Green Trust. Standard Chartered (SC) First Bank's 50% fund share by community chest, participation of volunteers, support of Busan City and Saba-gu, outside of that, sharing parts or trial to participate by diverse partnership of enterprise, public corporation and laboratory, these are the key in developing community garden's model. Established community garden places resulted food production to users of welfare center for the disabled, participating urban agricultural experience program, horticultural therapy, complex community chapter and cultural center. Furthermore, we could find the meaning of rooftop community garden in the point that it is a low cost garden by applying movable and unmovable planters. This study is profitable for improving urban environment, ensuring community chapter and urban green areas, regenerating a city to develop experimental community garden model by using a welfare house rooftop.

Long-term Results of Gamma Knife Radiosurgery for Craniopharyngioma (두개인두종의 감마나이프 치료 후 장기 추적 결과)

  • Kim, Yun Sok;Lee, Do Heui;Ra, Dong Suk;Chun, Young Il;Ahn, Jae Sung;Jeon, Sang Ryong;Kim, Jeong Hoon;Roh, Sung Woo;Ra, Young Shin;Kim, Chang Jin;Kwon, Yang;Rhim, Seung Chul;Lee, Jung Kyo;Kwun, Byung Duk
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.289-293
    • /
    • 2001
  • Objectives : The optimal treatment of craniopharyngioma is controversial. Despite recent advances in microsurgical management, complete surgical removal of craniopharyngioma remains very difficult. Radiation added to surgery is effective, but radiation therapy resulted in untoward side effect in young patient. Gamma knife radiosurgery offers the theoretical advantage of a reduced radiation dose to surrounding structures during the treatment of residual or recurrent craniopharyngioma compared with fractionated radiotheraphy. We described retrospective analysis of tumor size and clinical symptoms of patients after gamma knife radiosurgery in residual or recurrent craniopharyngioma were performed. Material and Methods : From September 1990 to January 2000, 18 patients of craniopharyngioma were treated by gamma knife radiosurgery. All patient had undergone surgery, but residual or recurrent tumor was found and all of them treated postoperative gamma knife radiosurgery. The mean age was 19(from 6 to 66) and male to female ratio was 10 to 8 and 8 patients were below 15 years old. In young age group(below age 15), the average volume of the tumor was $2904.8mm^3$ and mean maximal gamma knife dose was 34.9Gy. In old age group(older than 15), the average volume of the tumor was $2590.4mm^3$ and mean maximal gamma knife dose was 45.2Gy. The size of the tumor was average $2730.1mm^3$($88-12000mm^3$), mean average radiation dose was 40.7Gy and the mean prescription dose was 17.6 Gy(4-35Gy) delivered to a median prescription 50.7% isodose. Results : The follow up was from 1 year to 9 years(mean 59.1 months) after gamma knife radiosurgery. The tumor was controlled in 13(72.2%) patients. The tumor decreased in 9 patients and not changed in 4 patients. The tumor size increased in 4(22.2%) patients during follow up period. In two cases the tumor size increased because of its cystic portion was increased, but their solid portion of the tumor was not changed. In another two patients, the solid portion of the tumor was increased. So, one patient underwent reoperation and the other patient underwent operation and repeated gamma knife radiosurgery. The tumor recurred in one case(5.6%) that is a outside of irradiated site. The presenting symptoms were improved in 4 patients(improved visual acuity in 1, controlled increased intracranial presure sign in 3 patients). In one case, visual acuity decreased after gamma knife radiosurgery. The endocrine symptoms were not influenced by gamma knife radiosurgery. Conclusion : Craniopharyngioma can be treated successfully by gamma knife radiosurgery. Causes of the tumor regrowth are inadequate dose planning because of postoperatively poor margination of the tumor, close approximation of optic nerve and residual tumors outside the target lesion. Recurrence can develop 4 years after gamma knife radiosurgery. Volume is important, but the accurate targeting is more important to prevent tumor recurrence. If the tumor definition is not clear during planning gamma knife surgery, long-term image follow up is required.

  • PDF