• 제목/요약/키워드: Target Coverage

검색결과 307건 처리시간 0.027초

확률 커버리지 모델 기반의 스케줄링 기법 (A Scheduling Scheme under Probabilistic Coverage Model)

  • 김찬명;강인석;한연희
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2011년도 추계학술발표대회
    • /
    • pp.556-559
    • /
    • 2011
  • CTC(Connected Target Coverage)문제는 주어진 전체 타겟을 관측하고 관측한 데이터를 싱크노드까지 전송하는데 관여하는 센서집합의 개수를 최대화하여 네트워크 수명을 최대화하는 문제이다. 본 논문은 센서가 타겟을 관측할 확률이 타겟과의 거리에 영향을 받는다고 가정하는 확률 커버리지 모델을 기반으로 CTC문제에 접근한다. CTC문제를 해결하기 위해 휴리스틱 알고리즘인 CWGC-PM 알고리즘을 제안하고 시뮬레이션을 통해 알고리즘이 CTC문제를 해결하기에 적합함을 보인다.

Evaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc

  • Song, Ju-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.181-189
    • /
    • 2017
  • The conventional delivery quality assurance (DQA) process for RapidArc (Varian Medical Systems, Palo Alto, USA), has the limitation that it measures and analyzes the dose in a phantom material and cannot analyze the dosimetric changes under the motional organ condition. In this study, a DQA method was designed to overcome the limitations of the conventional DQA process for internal target volume (ITV) based RapidArc. The dynamic DQA measurement device was designed with a moving phantom that can simulate variable target motions. The dose distribution in the real volume of the target and organ-at-risk (OAR)s were reconstructed using 3DVH with the ArcCHECK (SunNuclear, Melbourne, USA) measurement data under the dynamic condition. A total of 10 ITV-based RapidArc plans for liver-cancer patients were analyzed with the designed dynamic DQA process. The average pass rate of gamma evaluation was $81.55{\pm}9.48%$ when the DQA dose was measured in the respiratory moving condition of the patient. Appropriate method was applied to correct the effect of moving phantom structures in the dose calculation, and DVH data of the real volume of target and OARs were created with the recalculated dose by the 3DVH program. We confirmed the valid dose coverage of a real target volume in the ITV-based RapidArc. The variable difference of the DVH of the OARs showed that dose variation can occur differently according to the location, shape, size and motion range of the target. The DQA process devised in this study can effectively evaluate the DVH of the real volume of the target and OARs in a respiratory moving condition in addition to the simple verification of the accuracy of the treatment machine. This can be helpful to predict the prognosis of treatment by the accurate dose analysis in the real target and OARs.

Policy for planned placement of sensor nodes in large scale wireless sensor network

  • Sharma, Vikrant;Patel, R.B;Bhadauria, HS;Prasad, D
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권7호
    • /
    • pp.3213-3230
    • /
    • 2016
  • Sensor node (SN) is a crucial part in any remote monitoring system. It is a device designed to monitor the particular changes taking place in its environs. Wireless sensor network (WSN) is a system formed by the set of wirelessly connected SNs placed at different geographical locations within a target region. Precise placement of SNs is appreciated, as it affects the efficiency and effectiveness of any WSN. The manual placement of SNs is only feasible for small scale regions. The task of SN placement becomes tedious, when the size of a target region is extremely large and manually unreachable. In this research article, an automated mechanism for fast and precise deployment of SNs in a large scale target region has been proposed. It uses an assembly of rotating cannons to launch the SNs from a moving carrier helicopter. The entire system is synchronized such that the launched SNs accurately land on the pre-computed desired locations (DLs). Simulation results show that the proposed model offers a simple, time efficient and effective technique to place SNs in a large scale target region.

Use of Flattening Filter Free Photon Beams for Off-axis Targets in Conformal Arc Stereotactic Body Radiation Therapy

  • Smith, Ashley;Kim, Siyong;Serago, Christopher;Hintenlang, Kathleen;Ko, Stephen;Vallow, Laura;Peterson, Jennifer;Hintenlang, David;Heckman, Michael;Buskirk, Steven
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.288-297
    • /
    • 2014
  • Dynamic conformal arc therapy (DCAT) and flattening-filter-free (FFF) beams are commonly adopted for efficient conformal dose delivery in stereotactic body radiation therapy (SBRT). Off-axis geometry (OAG) may be necessary to obtain full gantry rotation without collision, which has been shown to be beneficial for peripheral targets using flattened beams. In this study dose distributions in OAG using FFF were evaluated and the effect of mechanical rotation induced uncertainty was investigated. For the lateral target, OAG evaluation, sphere targets (2, 4, and 6 cm diameter) were placed at three locations (central axis, 3 cm off-axis, and 6 cm off-axis) in a representative patient CT set. For each target, DCAT plans under the same objective were obtained for 6X, 6FFF, 10X, and 10FFF. The parameters used to evaluate the quality of the plans were homogeneity index (HI), conformality indices (CI), and beam on time (BOT). Next, the mechanical rotation induced uncertainty was evaluated using five SBRT patient plans that were randomly selected from a group of patients with laterally located tumors. For each of the five cases, a plan was generated using OAG and CAG with the same prescription and coverage. Each was replanned to account for one degree collimator/couch rotation errors during delivery. Prescription isodose coverage, CI, and lung dose were evaluated. HI and CI values for the lateral target, OAG evaluation were similar for flattened and unflattened beams; however, 6FFF provided slightly better values than 10FFF in OAG. For all plans the HI and CI were acceptable with the maximum difference between flattened and unflattend beams being 0.1. FFF beams showed better conformality than flattened beams for low doses and small targets. Variation due to rotational error for isodose coverage, CI, and lung dose was generally smaller for CAG compared to OAG, with some of these comparisons reaching statistical significance. However, the variations in dose distributions for either treatment technique were small and may not be clinically significant. FFF beams showed acceptable dose distributions in OAG. Although 10FFF provides more dramatic BOT reduction, it generally provides less favorable dosimetric indices compared to 6FFF in OAG. Mechanical uncertainty in collimator and couch rotation had an increased effect for OAG compared to CAG; however, the variations in dose distributions for either treatment technique were minimal.

Volumetric modulated arc therapy for carotid sparing in the management of early glottic cancer

  • Kim, Young Suk;Lee, Jaegi;Park, Jong In;Sung, Wonmo;Lee, Sol Min;Kim, Gwi Eon
    • Radiation Oncology Journal
    • /
    • 제34권1호
    • /
    • pp.18-25
    • /
    • 2016
  • Purpose: Radiotherapy of the neck is known to cause carotid artery stenosis. We compared the carotid artery dose received between volumetric modulated arc therapy (VMAT) and conventional fixed-field intensity-modulated radiotherapy (IMRT) plans in patients with early glottic cancer. Materials and Methods: Twenty-one early glottic cancer patients who previously underwent definitive radiotherapy were selected for this study. For each patient, double arc VMAT, 8-field IMRT, 3-dimensional conformal radiotherapy (3DCRT), and lateral parallel-opposed photon field radiotherapy (LPRT) plans were created. The 3DCRT plan was generated using lateral parallel-opposed photon fields plus an anterior photon field. VMAT and IMRT treatment plan optimization was performed under standardized conditions to obtain adequate target volume coverage and spare the carotid artery. Dose-volume specifications for the VMAT, IMRT, 3DCRT, and LPRT plans were calculated with radiotherapy planning system. Monitor units (MUs) and delivery time were measured to evaluate treatment efficiency. Results: Target volume coverage and homogeneity results were comparable between VMAT and IMRT; however, VMAT was superior to IMRT for carotid artery dose sparing. The mean dose to the carotid arteries in double arc VMAT was reduced by 6.8% compared to fixed-field IMRT (p < 0.001). The MUs for VMAT and IMRT were not significantly different (p = 0.089). VMAT allowed an approximately two-fold reduction in treatment delivery time in comparison to IMRT (3 to 5 minutes vs. 5 to 10 minutes). Conclusion: VMAT resulted in a lower carotid artery dose compared to conventional fixed-field IMRT, and maintained good target coverage in patients with early glottic cancer.

Quality of Breast Cancer Early Detection Services Conducted by Well Woman Clinics in the District of Gampaha, Sri Lanka

  • Vithana, Palatiyana Vithanage Sajeewanie Chiranthika;Ariyaratne, M.A.Y.;Jayawardana, P.L.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권1호
    • /
    • pp.75-80
    • /
    • 2013
  • Background: Breast cancer is the most common cancer diagnosed in females in Sri Lanka and early detection can lead to reduction in morbidity and mortality. Aim: To evaluate selected aspects of breast cancer early detection services implemented through well woman clinics (WWCs) in the Gampaha District. Methods: The study consisted of two components. A retrospective descriptive arm assessed clinical breast examination (CBE) coverage of target age group women (TGW) of 35-59 years in all the WWCs in Gampaha district over 2003-2007. A cross sectional descriptive study additionally assessed quality of breast cancer early detection services. The Lot Quality Assurance Sampling (LQAS) technique was used to decide on the lot size and threshold values, which were computed as twenty and six clinics. Checklists were employed in assessing coverage, physical facilities and clinic activities. Client satisfaction on WWC services was assessed among 200 TGW attending 20 WWCs using an interviewer-administered questionnaire. Results: CBE coverage in the Gampaha district increased only from 1.1-2.2% over 2003-2007. With regard to physical facilities, the number of clinics that were rated substandard varied between 7-18 (35-90%). The items that were lacking included dust bins, notice boards, stationary, furniture and linen, and cleanliness of outside premises and toilets. With regard to clinic activities, punctuality of staff, late commencement of clinics, provision of health education, supervision, CBE and breast self-examination (BSE) were substandard in 7-20 clinics (35-100%). Client satisfaction for WWC services was 45.2% (IQR: 38.7-54.8%) and only 11% had a score of ${\geq}70%$, the cut off set for satisfaction. Conclusions: Breast cancer early detection service coverage in the Gampaha district remained low (2.2%) in 2007, 11 years after commencing WWCs. All 20 clinics were substandard for overall CBE and BSE.

건강보험 보장성 확대정책의 집행분석: Winter의 정책집행모형의 적용 (An Implementation Analysis of the National Health Insurance Coverage Expansion Policy in Korea: Application of the Winter Implementation Model)

  • 유수연;강민아;권순만
    • 보건행정학회지
    • /
    • 제24권3호
    • /
    • pp.205-218
    • /
    • 2014
  • Background: Most studies on the national health insurance benefit expansion policy have focused on policy tools or decision-making process. Hence there was not enough understanding on how policies are actually implemented within the specific policy context in Korea which has a national mandatory health insurance system with a dominant proportion of private providers. The main objectives of this study is to understand the implementation process of the benefit coverage expansion policy. Unlike other implementation studies, we tried to examine both the process of implementation and decision making and how they interact with each other. Methods: Interviews were conducted with the ex-members of the Health Insurance Policy Review Committee. Medical doctors who implement the policy at the 'street-level' were also interviewed. To figure out major variables and the degree of their influences, the data were analyzed with Winter's Policy Implementation Model which integrates the decision making and implementation phases. Results: As predicted by the Winter model, problems in the decision making phase, such as conflicts among the members of committee, lack of applicable causal theories application of highly symbolic activities, and limited attention of citizen to the issue are key variables that cause the 'implementation failure.' In the implementation phase, hospitals' own financial interests and practitioners' dependence on the hospitals' guidance were barriers to meeting the policy goals of providing a better coverage for patients. Patients, the target group, tend to prefer physicians who prescribe more treatment and medicine. To note, 'fixers' who can link and fill the gap between the decision-makers and implementers were not present. Conclusion: For achieving the policy goal of providing a better and more coverage to patients, the critical roles of medical providers as street-level implementers should be noted. Also decision making process of benefit package expansion policy should incorporate its influence on the implementation phase.

Key Principles of Clinical Validation, Device Approval, and Insurance Coverage Decisions of Artificial Intelligence

  • Seong Ho Park;Jaesoon Choi;Jeong-Sik Byeon
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.442-453
    • /
    • 2021
  • Artificial intelligence (AI) will likely affect various fields of medicine. This article aims to explain the fundamental principles of clinical validation, device approval, and insurance coverage decisions of AI algorithms for medical diagnosis and prediction. Discrimination accuracy of AI algorithms is often evaluated with the Dice similarity coefficient, sensitivity, specificity, and traditional or free-response receiver operating characteristic curves. Calibration accuracy should also be assessed, especially for algorithms that provide probabilities to users. As current AI algorithms have limited generalizability to real-world practice, clinical validation of AI should put it to proper external testing and assisting roles. External testing could adopt diagnostic case-control or diagnostic cohort designs. A diagnostic case-control study evaluates the technical validity/accuracy of AI while the latter tests the clinical validity/accuracy of AI in samples representing target patients in real-world clinical scenarios. Ultimate clinical validation of AI requires evaluations of its impact on patient outcomes, referred to as clinical utility, and for which randomized clinical trials are ideal. Device approval of AI is typically granted with proof of technical validity/accuracy and thus does not intend to directly indicate if AI is beneficial for patient care or if it improves patient outcomes. Neither can it categorically address the issue of limited generalizability of AI. After achieving device approval, it is up to medical professionals to determine if the approved AI algorithms are beneficial for real-world patient care. Insurance coverage decisions generally require a demonstration of clinical utility that the use of AI has improved patient outcomes.

Noninformative priors for the common location parameter in half-normal distributions

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제21권4호
    • /
    • pp.757-764
    • /
    • 2010
  • In this paper, we develop the reference priors for the common location parameter in the half-normal distributions with unequal scale paramters. We derive the reference priors as noninformative prior and prove the propriety of joint posterior distribution under the general prior including the reference priors. Through the simulation study, we show that the proposed reference priors match the target coverage probabilities in a frequentist sense.

Noninformative priors for the reliability function of two-parameter exponential distribution

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제22권2호
    • /
    • pp.361-369
    • /
    • 2011
  • In this paper, we develop the reference and the matching priors for the reliability function of two-parameter exponential distribution. We derive the reference priors and the matching prior, and prove the propriety of joint posterior distribution under the general prior including the reference priors and the matching prior. Through the sim-ulation study, we show that the proposed reference priors match the target coverage probabilities in a frequentist sense.