• Title/Summary/Keyword: Tap Water Use

Search Result 84, Processing Time 0.032 seconds

Development of an Optimal Operation Model of Residual Chlorine Concentration in Water Supply System (송·배수시스템의 최적 잔류염소농도 관리 모델 개발)

  • Kim, Kibum;Hyung, Jinseok;Seo, Jeewon;Shin, Hwisu;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.587-597
    • /
    • 2017
  • This study aimed to develop a method to optimize residual chlorine concentrations in the process of providing water supply. To this end, this study developed a model capable of optimizing the chlorine input into the clearwell in the purification plant and the optimal installation location of rechlorination facilities, and chlorine input. This study applied genetic algorithms finding the optimal point with appropriate residual chlorine concentrations and deriving a cost-optimal solution. The developed model was applied to SN purification plant supply area. As a result, it was possible to meet the target residual chlorine concentration with the minimum cost. Also, the optimal operation method in target area according to the water temperature and volume of supply was suggested. On the basis of the results, this study derived the most economical operational method of coping with water pollution in the process of providing water supply and satisfying the service level required by consumers in the aspects of cost effectiveness. It is considered possible to appropriately respond to increasing service level required by consumers in the future and to use the study results to establish an operational management plan in a short-term perspective.

The Experimental Study of Liquid Phase Mixing Mechanism of Split Triplet Impinging Spray (분리 충돌형 분사기의 액상 혼합 메커니즘에 관한 실험적 고찰)

  • 이성웅;조용호;윤웅섭
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.18-23
    • /
    • 2002
  • Liquid phase mixing of impinging injector is a resultant byproduct from the momentum exchange between a pair of impinging jets and penetration of opponent jet. Principal aim of the present study is revealing the liquid phase mixing mechanism of split triplet impinging injection sprays, and thus extending our understanding on this particular injection element. Overall mixing extent is estimated from patternation tests by the use of purified tap water and kerosene to simulate the real propellant components, respectively, and with the liquid jet momentum ratio, a controlling mixing parameter, in the range of 0.5 to 6.0. Emphasis is placed on the effect of liquid sheet superposition and disintegration, and the results with detailed spray visualization revealed the fact that superposed liquid sheet disintegration is the main pathway of liquid phase mixing of split triplet impinging injector to yield enhanced mixing qualities.

  • PDF

Determinant Factor Analysis for the Spread of Water Reuse (물재이용 활성화를 위한 결정요인분석)

  • Park, Hyunju;Kim, Tschungil;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • The purpose of this study was to survey Suwon citizens over the age of 20 in order to provide basic data on the extent of coverage of the city's water reclamation system and to set guidelines for a policy on water reuse. The survey used a questionnaire with two fields, rainwater use and wastewater recycling, for analyzing factors that influenced water reuse. A factor analysis of 19 questionnaires gave a Cronbach's alpha coefficient greater than 0.4. Factors that influenced rainwater use were environmental protection, water charges, and the risk of climate change. Of the total explanatory power, the share of rainwater use and environmental protection was 39.7% and 28.1% respectively. Environmental protection (explanatory power 24.2%) had an effect on the explanatory power of wastewater reuse. When factors influencing wastewater recycling, like cost of recycling, water management policy, climate change, and suspension of tap water supply were included, the explanatory power of each of these factors went up by 4.3%, 2.8%, 3.3%, and 1.1%, respectively. For more effective wastewater recycling, a water management policy that factors in the above is required, along with a campaign to educate citizens on water management and environment conservation. Additionally, it may be necessary to improve the reliability and the quality of water supply.

Biohydrogen production from engineered microalgae Chlamydomonas reinhardtii

  • Kose, Ayse;Oncel, Suphi S.
    • Advances in Energy Research
    • /
    • v.2 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • The green microalgae Chlamydomonas reinhardtti is well-known specie in the terms of $H_2$ production by photo fermentation and has been studying for a long time. Although the $H_2$ production yield is promising; there are some bottlenecks to enhance the yield and efficiency to focus on a well-designed, sustainable production and also scaling up for further studies. D1 protein of photosystem II (PSII) plays an important role in photosystem damage repair and related to $H_2$ production. Because Chlamydomonas is the model algae and the genetic basis is well-studied; metabolic engineering tools are intended to use for enhanced production. Mutations are focused on D1 protein which aims long-lasting hydrogen production by blocking the PSII repair system thus $O_2$ sensitive hydrogenases catalysis hydrogen production for a longer period of time under anaerobic and sulfur deprived conditions. Chlamydomonas CC124 as control strain and D1 mutant strains(D240, D239-40 and D240-41)are cultured photomixotrophically at $80{\mu}mol\;photons\;m^{-2}s^{-1}$, by two sides. Cells are grown in TAP medium as aerobic stage for culture growth; in logarithmic phase cells are transferred from aerobic to an anaerobic and sulfur deprived TAP- S medium and 12 mg/L initial chlorophyll content for $H_2$ production which is monitored by the water columns and later detected by Gas Chromatography. Total produced hydrogen was $82{\pm}10$, $180{\pm}20$, $196{\pm}20$, $290{\pm}30mL$ for CC124, D240, D239-40, D240-41, respectively. $H_2$ production rates for mutant strains was $1.3{\pm}0.5mL/L.h$ meanwhile CC124 showed 2-3 fold lower rate as $0.57{\pm}0.2mL/L.h$. Hydrogen production period was $5{\pm}2days$ for CC124 and mutants showed a longer production time for $9{\pm}2days$. It is seen from the results that $H_2$ productions for mutant strains have a significant effect in terms of productivity, yield and production time.

Colony Counts by Different Disinfecting Processes and Operating Time for Humidifiers in an Intensive Care Unit (중환자실 내 가습기의 소독방법과 시간적 경과에 따른 균집락 수)

  • Park, Soon-Mi;Jeong, Ihn-Sook;Chang, Chul-Hun L.;Lee, Young-Soon
    • Journal of Korean Biological Nursing Science
    • /
    • v.11 no.1
    • /
    • pp.92-98
    • /
    • 2009
  • Purpose: This study was aimed to investigate the colony counts by different disinfecting processes and duration of the operation for humidifiers in an intensive care unit (ICU) in Busan. Method: The four steps of disinfecting process were taken with four different humidifiers according to the use of disinfectant (1:100 $Deconex^{(R)}$ 50FF/nothing) and refilling water (tap water/distilled water). First, the colony counts using water sample from wick was conducted at 0 hr, 24 hr, and 48 hr respectively after turning on the humidifiers. Next, the colony counts using waterdrop from the outlet was done at 0 hr, 24 hr, 48 hr, and 72 hr respectively after turning on the humidifiers. Result: No colony was counted after disinfecting with 1:100 $Deconex^{(R)}$ 50FF until 72 hr after turning on the humidifiers. However, without disinfecting with $Deconex^{(R)}$ 50FF, the colony count was increased in the humidifiers from 24 hr after turning on the humidifiers. The result was the same regardless of the refilling water. Conclusion: According to the results, the study found that disinfection of humidifiers in the ICUs with 1:100 $Deconex^{(R)}$ 50FF every 72 hr is effective to remove general bacteria.

  • PDF

A Study on the Management & Utilization of School Drinking Water (학교음용수 관리 및 이용실태)

  • Hong, Jung-Ha;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.2
    • /
    • pp.87-104
    • /
    • 2000
  • The purpose of this study was to obtain the basic data as a improvement method through the fact-revealing concerning the drinking water management of school and utilization of student. The problems of the research are as follows: First, to investigate status of management of drinking water by area and school. Second, to investigate student's utilization of drinking water by area and school. 1,400 students was selected at 45 elementary and middle-high schools located in Kang-won province, and this study was constituted of two questionnaires(for school's questionnaire and student's questionnaire). The results was analyse through the frequency analysis, $x^2$-test on the basis of the above research problem by SPSS program. The findings of this research are as follows; 1) The Management of School Drinking Water First, the source of school drinking water was mostly piped water. Inspection of water quality has been fulfilled under four times a year, in the other hands, from the result inspection, the schools which was given inadequate determination was 22.2%. Second, reservoir cleaning and hygiene inspection failed far short of the regulations. Especially, reservoir cleaning was managed by exterior consignment industry not low-level officials. Third, school water drinking was the most supplied through the type of water purifier. Water purifier has been distributed to city-located and middle-high school highly, factually the water from water purifier was served with water cup. Fourth, the selection standard of water drinking manager showed slightly differently by school, accordingly there need to develope integrated system with the respective to its effective systematic management. Fifth, water cup was mostly treated by only water clear, which is to vindicate the problems concerning hygiene management. 2) Utilization of school student on Drinking Water First, Disbelief on drinking water of school student was very high. Especially, proportion of middle-high school student's disbelief of drinking water was higher than elementary school student, also girls higher than boys. Many of student have heard to don't drink water from around people. And there were showed meaningful differences by area and school. Second, It was showed many student recognize had to utilize water purifier, boiled water. However, they have still drunken the tap water or portable water from their home. Third, Many of student showed negative response with the respective to the management conditions of drinking water in classroom, There were showed meaningful differences by area and school. From the fact-revealing of water cup management, Students mostly answered to 'only water clear' and the answer of 'None use' or 'With personal cup' was higher. Fourth, In bad experience of Drinking Water, student mostly answered to 'occasionally' and there were showed meaningful differences by school. student's disease experience with school drinking water was few and there were showed meaningful differences by area and gender.

  • PDF

Characteristics of Radon Reduction of Small-scale Water Supply System (소규모수도시설 지하수의 라돈저감 특성)

  • Cho, Byong-Wook
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.37-50
    • /
    • 2019
  • It is possible that radon removal in groundwater of small-scale water supply system (SWSS) is caused by atmospheric storage and aeration facilities installed in the water tank. Radon removal rates at water tank and tap of the 32 SWSS during summer season ranged from -69.3% to 62.7% (average 25.7%) and from -64.3% to 83.1% (average 30.3%) while those of 16 SWSS during autumn season ranged from 21.3% to 78.0% (average 42.8%) and from 17.7% to 66.9% (average 44.8%). The reason of higher radon removal rate in the autumn season compared with the summer season is due to higher atmospheric storage effect by lower groundwater use rate. The radon removal rates at the water tank from 12 SWSS were 47.4~94.0% (average 78.9%), in which the removal rates at the atmospheric storage are also included. Atmospheric storage and aeration can be used to reduce radon concentration in SWSS groundwater. For more efficient use of radon reduction, further studies are necessary to assess the radon removal rate considering variation conditions of radon concentration in groundwater, size and forms of water tank, change in groundwater usage rate, aeration capacity and ventilation facilities.

Urban Development and Social Circulation of Water in Daegu (대구의 도시 발달과 물의 사회적 순환)

  • Choi, Byung Doo
    • Journal of the Korean association of regional geographers
    • /
    • v.19 no.1
    • /
    • pp.75-96
    • /
    • 2013
  • This paper is to conceptualize the urban social circulation of water from the social constructivism and political ecology, and to analyze the history of development of social circulation of water, that is, the modernization process of water in Daegu. The development of social circulation system of water in Daegu can be divided into 4 stages, that is, the beginning stage of modernization of water mainly during the period of Japanese colonization, the take-off stage from the 1960s to the mid-1980s, the stage of reflexive modernization from the late 1980s to the 1990s, and that of neoliberalization of water since the 2000s. It can be seen that the development of social circulation system of water in Daegu has contributed the increasing urban population and economic development, especially supporting the spatial expansion of the city and the way of modern way of urban life. But the social circulation system of water in Daegu seems to meet with a lot of problems such as relocation of the water intake station, over-equipment of filtration plants, distrust on tap water, inequality of water use, readjustment of water charge, liquid waste from industrial complexes within the urban area, creative destruction of waterfront environment, and privatization of water.

  • PDF

A survey on the awareness of water fluoridation concentration regulation project of some elementary school (대전시 일부 초등학교 일반교사와 보건교사의 수돗물 불소농도조정사업의 인식도조사)

  • Lee, Tae-Yong;Seung, Bo-Kyun;Kim, Jee-Hee;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1929-1935
    • /
    • 2010
  • Approximately 110 elementary schools and 400 teachers in Dae Jeon metropolitan city were chosen for this research, by using the method of direct visit and survey by mail. The survey was performed as in the forms of self administration, by simple statistic extract method, and among the survey, insincere answers and partly omitted contents were removed, which left 348 survey questionnaires to use for the final research. In order to restore the tap water fluorine concentration regulation project in Dae Jeon, advertise its benefits; it offered precise knowledge and positive response of fluorine through education on oral disease prevention, provide correct knowledge, administrative support should follow to support its importance.

Comparison of Bacterial Regrowth on Plant- and Coal-based Granular Activated Carbon (식물계활성탄과 석탄계활성탄에서의 세균재생장 비교)

  • 이동근;박성주;하배진;하종명;이상현;이재화
    • KSBB Journal
    • /
    • v.19 no.2
    • /
    • pp.104-109
    • /
    • 2004
  • Activated carbon has been used in water treatment, because they strongly adsorb organic material including contaminant. Water purifier usually use activated carbon, and bacterial regrowth on that could induce many problems. Model columns, packed with coal- and plant-based granular activated carbon (GAC), were operated with rechlorinated tap water to compare the degree of bacterial regrowth on different GACs. GAC columns decreased the concentration of total organic carbon and chlorine, while they are not good for the decrease of ions. Breakthrough of bacteria were occurred after eight days of operation, and reached 1.1 ${\times}$ 10$^3$ CFU/mL on coal based GAC and 6.2 ${\times}$ 10$^2$ CFU/mL on coconut based one. Bacterial activities on GAC were between 15.35 ∼ 29.06 $\mu\textrm{g}$ INT-formazan/g-GAC/h. Bacterial concentration and activities were higher in coal based GAC than coconut based one. Bacterial regrowth on GAC was clarified and regrowth effect of coal-based GAC was higher than that of coconut-based one.