• Title/Summary/Keyword: TRIGGER

Search Result 1,474, Processing Time 0.02 seconds

Common Trigger Points on College-Level Athletes with Various Sports

  • Park, Joo-Hyun;Shin, Hee-Joon;Lee, Sa-Gyeom;Lee, Geon-Cheol;Yoon, Hee-Jong;Hong, Wan-Sung;Goo, Bong-Oh;Lee, Dong-Yeop;Shin, Hyung-Soo;Yoon, Bum-Chul
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.1 no.1
    • /
    • pp.58-64
    • /
    • 2010
  • The purpose of this study was to investigate the distribution of trigger points(TrPs) on athletes with various sporting background. To achieve the purpose, a study was carried out through a survey from 180 athletes involved in 6 selected sports at Yong-In University. Selected sports included Judo, Taekwondo, Kendo, Ssi-reum(Korean traditional wrestling), Boxing, and Golf. An interview type survey and physical examination were conducted with each thirty athletes from each of the selected sports groups. Technical statistic(SPSS 15.0) was used to analyze the distribution of TrPs on these athletes. The most common TrPs observed in muscles of Trapezius, Quadratus Lumborum, Quadriceps in Judo. In Taekwondo, it was on the trapezius and triceps surae. Kendo athletes had TrPs at sites of trapezius, brachioradialis and triceps surae. Ssirem athletes were found to have TrPs on trapezius, deltoid and quadrates lumborum. In boxers, TrPs appearing at trapezius and brachioradialis were observed. Finally, Golf players were seen to have TrPs at trapezius, quadrates lumborum and brachioradialis. Hence, the analysis shows that there are significant differences of the distribution of TrPs according to the different sport items of the athlete.

  • PDF

Studies on the Regulation of Calcium Activity in Myocardial Contraction (심근 수축에 있어서 Calcium작용의 조절에 관한 연구)

  • Ko, Chang-Mann;Hong, Sa-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.26 no.2
    • /
    • pp.113-120
    • /
    • 1990
  • Influences of trigger calcium on myocardial contraction from several sources were investigated on the frequency reduction-induced changes of contraction in rat left atria driven by electrical field stimulation. Rat atria elicited characteristic three phase-changes according to frequency reduction: the first rapid rise in twitch tension, the second transient fast decrease in tension and the third maintenance of twitch tension at about 200% of resting tension during high frequency. Caffeine treatment enormously suppressed the frequency reduction-induced twitch tension increase. The atrial contraction during high frequency vanished after verapamil treatment. But, during low frequency, atrial contraction revived in the presence of verapamil. Ouabain treatment and sodium depletion in superfusing solution abolished the characteristic second phase with slow frequency. These results suggest that slow calcium channel is an indispensable calcium entry route and calcium release from sarcoplasmic reticulum is an major source for trigger calcium in cardiac contraction. And sodium-calcium exchange has a modulatory roles in the regualtion of trigger calcium according to the changes of intracellular sodium concentration.

  • PDF

The Use of Skin Resistance Point Finder for the Diagnosis of Myofascial Trigger Points (피부 저항점 탐지기를 사용한 근근막 통증 유발점의 진단)

  • Kang, Mi-Suk;Hong, Jung-Eun;Lim, Young-Jin;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.12 no.2
    • /
    • pp.195-199
    • /
    • 1999
  • Background: At present, there is no reliable objective test for the diagnosis of myofascial trigger points (MFTP). We evaluated the usefulness of skin resistance point finder for the diagnosis of MFTP. Methods: 40 subjects with clinical MFTPs at the upper trapezius muscle were included in this study. Using skin resistance point finder (UNIQUE S-2010$^{(R)}$, Seik medical, Korea), we tried to find out the point of low skin resistance. At three different current level, sensitivity and specificity of this method for the diagnosis of clinically identified MFTP was evaluated. Pressure threshold for pain of low skin resistance point was measured using Pressure Threshold Meter$^{(R)}$ (Pain Diagnostics and Thermography, U.S.A.). 3 groups of point detected at different current were compared in mean pressure threshold. Results: Fixed single current of skin resistance point finder showed variable sensitivity and specificity. But, by adjusting current level, skin resistance point finder detected all of 40 clinically identified MFTPs. Although it is partially statistically significant, the mean pressure threshold of points detected at high current was high. Conclusion: Skin resistance finder can be used as objective diagnostic tool of MFTPs. There is possibility that it can be useful in evaluating treatment effect. However, more investigation is necessary.

  • PDF

Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element (초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.112-116
    • /
    • 2010
  • As one of the countermeasures to improve the recovery characteristics of the SFCL (superconducting fault current limiter), the method using the trigger of high-TC superconducting element (HTSC) when the quench in the HTSC element occurred was proposed. To confirm the suggested method, the control circuit to detect the quench occurrence of HTSC element in case of the fault occurrence was designed and the current limiting and recovery experiments of the SFCL using the designed control circuit were performed. Through the analysis for the experimental results, the points of both the open time and the closing time of a power switch comprising the control circuit could be adjusted by the resistance amplitude of a normal conducting current limiting resistor (CLR) and the recovery characteristics of the SFCL together with the current limiting operation could be confirmed to be improved by using the control circuit.

Effects of Electrotherapy on the Deactivation of Trigger points (전기치료가 발통점 비활성화에 미치는 효과)

  • Joung, Ho-Bal;Bang, Sang-Bun
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • The purpose of this study is to compare Ultra Sound(U-S), Silver Spike Point(SSP) and Electro-Acupuncture(E-A) with each other and to objectively analyze their concrete validities and their effects on the deactivation of trigger points in patients with myofascial pain syndrome, and to provide basic necessary principles for clinical therapists. Sixty patients were randomly distributed into three groups of twenty persons each and the U-S, the SSP and the E-A were applied to each group respectively. Tree pain evaluation methods of VAS(Visual Analogue Scale), Electrical Stimulation Scale and Pressure Algometer were adopted to measure the effectiveness of each therapy. The results were as follows: The U-S and E-A groups demonstrated statistically significant decrease on the VAS. The pain thresholds by Electrical Stimulation Scale method was increased for all the groups of U-S, SSP and E-A with no statistical significance. however, Pressure Algometer method was found to increase the pain thresholds for both SSP and E-A groups with statistically significance. Statistically significant improvement was found for all the groups together after the administration of the U-S, the SSP and the E-A. From the above results, three methods of U-S, SSP and E-A are found to be effective tools for the deactivation of trigger points in patients with upper trapezius muscle of Myofascial Pain Syndrome. The E-A method was found to be the most effective among three methods.

  • PDF

A Comparative Study of IP Mobility Protocols : Fast Handover vs. Mobile IPv6 (IP 이동성 지원 프로토콜에 대한 비교 연구: Fast Handover 대 Mobile IPv6)

  • 백상헌;최양희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.6A
    • /
    • pp.651-659
    • /
    • 2004
  • The Fast Handover protocol [1] provides seameless handover in wireless If networks by minimizing handover latency, which uses anticipation based on layer 2 (L2) trigger information. Therefore, it incurs higher signaling costs compared with the basic Mobile U protocol. Furthermore, since the L2 trigger is based on fluctuating wireless channel states, the handover anticipation may sometimes be incorrect. In the case of incorrect anticipation, unnecessary buffer space may be used for the purpose of providing a smooth handover. Therefore, it is essentical to analyze these overhead costs, in order to evaluate and compare the performance of Fast Handover with that of the basic Mobile U protocol. In this paper, we analyzed the overhead associated with Fast Handover including the signaling cost and the packet delivery cost. We formulated these costs based on a timing diagram and compared Fast Handover with basic Mobile Ipv6 in terms of their packet loss rates and buffer requirements. Also, we studied the impact of the L2 triggering time on the total overhead cost.

Study of Types of Questions Presented in Software and Robot Units of 2015 Revised Elementary School Practical Curriculum and Development of CT Trigger Questioning (2015 개정 교육과정 초등 실과 교과서 소프트웨어와 로봇 단원 발문 분석 및 CT마중발문 개발)

  • OH, Jeongcheol;Jin, Yeongji;Kim, Bongchul;Kim, Jonghoon
    • Journal of The Korean Association of Information Education
    • /
    • v.24 no.3
    • /
    • pp.215-223
    • /
    • 2020
  • The results of the analysis of the 523 questions presented in the six textbooks and SW and robot units in the Blosser four-step classification categories are as follows. First, in the software unit, the analysis results showed that 77.1% were closed questions and 22.9% were open questions. Second, in the robot unit, the analysis results showed that 74.8% were closed questions and 25.2% were open questions. The CT Trigger Question was developed to overcome the limitations of the textbook questions, which were mainly closed questions, and to directly or indirectly induce computational thinking that teachers can utilize according to their educational content and activities.

Correlation between the Pressure Pain Threshold and Sonography and Spontaneous Electrical Activity in Myofascial Trigger Points

  • Kim, Hyun-Jin;Kim, Myung-Hoon;Kim, Su-Hyon;Oh, Seok;Choi, Ji-Ho;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.3
    • /
    • pp.17-21
    • /
    • 2010
  • Purpose: This study was designed to investigate possibilities for quantitative analysis using the electromyography and sonography. For better understanding, we evaluated the correlation between the pressure pain threshold and sonography, spontaneous electrical activity in trigger points located in the upper trapezius muscle. Methods: Thirty three active subjects volunteered to participate in this study (n=33). They had a palpable taut band, exquisite spot tenderness of a nodule in a taut band, spontaneous pain, referred pain, jump sign, local twitch response, and a painful limit to full stretch range of motion. We measured Pressure pain threshold, density, white area index, root mean square, and reaction. Pearson’s correlation coefficient was calculated to estimate the relationship between the pressure pain threshold and other variables including density, white area index, root mean square, and reaction time. Results: There were significant correlations between pressure pain threshold and density (r=-0.75, p<0.01), and between pressure pain threshold and white area index (r=-0.74, p<0.01). A significant correlations between pressure pain threshold and root mean square (r=-0.59, p<0.01). The significant correlation was found between pressure pain threshold and reaction time (r=-0.64, p<0.01). Conclusion: These should indicate whether quantitative analysis can be done using the characteristics of electromyography and sonography.

Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current (고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Hong, M.S.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF