Y. Jang;Lee, D.;Kim, H.;Lee, J.;Park, C.G.;Lee, H.K.;Kim, S.;D. Suh
대한자기공명의과학회:학술대회논문집
/
대한자기공명의과학회 2003년도 제8차 학술대회 초록집
/
pp.98-98
/
2003
We will present various MR findings of hyperacute ischemic stroke with our own experiences in the management of the patients according to the findings. 대상 및 방법: A total of 441 patients were underwent 'acute stroke MR' imaging protocol between Mar. 2001 and Jun. 2003. The protocol included initial T2-weighted image (WI), diffusion WI (DWI, b=2000), time-of-flight (TOF) MR angiography (MRA), and pefusion WI(PWI), and follow-up T2WI, DWI, TOF MRA, and neck vessel contrast-enhanced MRA obtained three to five days after the insult. Among them, we retrospectively reviewed the MR findings and clinical courses of 193 patients with anterior circulation territorial infarction. Those ICA and MCA lesions were divided into six and five groups respectively according to the level and mechanism of the occlusion. PWI findings can be another factor in the management planning.
본 연구에서는 검사시간을 단축시키면서 해상도를 증가시키는 Compressed SENSE를 TOF에 적용하여 SENSE와 CS 기법에 대한 영상의 질을 비교하고 SNR, CNR을 평가하여 최적의 기법을 알아보고 이러한 정보를 토대로 임상적 기초자료로 제공하고자 한다. 충청도 소재 한 대학병원에서 TOF MRA 검사를 시행한 환자 32명(남자 15명, 여자 17명, ICA stenosis:10, M1 aneurysm:10, 평균나이 53 ± 4.15)을 대상으로 데이터를 분석하였다. 검사에 적용된 장비는 Ingenia CX 3.0T, Archieva 3.0 T 두 기기를 이용하였고 데이터 획득을 위한 방법으로 32 Channel Head Coil과 3D Gradient echo 이었다. 정량적 분석으로 각 영상의 SNR과 CNR을 측정하고 정성적 평가를 위해 관찰자의 시각적 견해에 대하여 5등급으로 나누어 영상의 질을 평가하였다. 영상평가는 paired t-test와 Wilcoxon 검정을 하였으며 p 값이 0.05 이하 일 때 유의성이 있는 것으로 간주하였다. TOF MRA 영상에서 SNR과 CNR에 대한 정량적 분석 결과 SENSE 기법에 비해 CS 기법이 높게 측정되었다(p<0.05). 관찰자의 시각적 평가로서 혈관의 선예도: CS(4.45 ± 0.41), 전반적인 영상의질: CS(4.77 ± 0.18), 영상의 배경소거: CS(4.57 ± 0.18)는 모두 CS 기법이 높은 결과를 얻었다(p=0.000). 결론적으로, 유속증가 자기공명혈관 조영술에서 SENSE 와 Compressed SENSE 기법을 비교하여 평가했을 때 Compressed SENSE TOF MRA 기법이 우위의 결과를 보여주었다. 이러한 결과는 뇌 질환 3D TOF MRA 검사에서 향후 임상적 기초자료가 될 것이라고 생각한다.
Purpose: To assess associations between morphological characteristics of intracranial arteries in time-of-flight MR angiography (TOF-MRA) and atherosclerotic risk factors. Materials and Methods: From January 2014 to October 2015, a total of 129 patients (65 men and 64 women) without intracranial arterial stenosis > 50% were included in this study. All MRIs were performed using a 3T machine with 3D TOF-MRA sequences. We evaluated irregularity, tortuosity, and dilatation of intracranial arteries in maximal intensity projection (MIP) of TOF-MRA. Subjects' risk factors for atherosclerosis including history of hypertension and diabetes were collected by reviewing their medical records. Associations between morphological characteristics and each known atherosclerosis risk factor were examined using univariate regression analysis. Multivariate regression models were built to determine combined association between those risk factors and morphologic changes of intracranial arteries. Results: In multivariate analysis, hypertension (coefficient [95% CI]: 0.162 [0.036, 0.289], P = 0.012) and absence of diabetes (coefficient [95% CI]: -0.159 [-0.296, -0.023], P = 0.022) were associated with large diameter of intracranial arteries. Males (coefficient [95% CI]: 0.11 [-0.006, 0.23], P = 0.062) and higher age (coefficient [95% CI]: 0.003 [-0.001, 0.008], P = 0.138) had marginal association with increased diameter. Tortuosity was associated with old age (OR: 1.04 [1.02, 1.07], P < 0.001). Irregular contour of intracranial arteries was significantly associated with old age (OR: 1.05 [1.02, 1.09], P = 0.004), presence of diabetes (OR: 2.88 [1.36, 6.15], P = 0.0058), and previous ischemic stroke (OR: 3.91 [1.41, 11.16], P = 0.0092). Conclusion: Morphological characteristics (irregularity, tortuosity, dilatation) of intracranial arteries seen in TOF-MRA might be associated with atherosclerotic risk factors in subjects with no or mild stenosis.
Contrast-enhanced MR angiography (CE-MRA) gradually occupies its position as a primary evaluation tool forsteno-occlusive disease of supra-aortic cervical arteries. It has several advantages over time-of-flight (TOF) technique such as shorter imaging time, less saturation effect, and less flow- and motion-related artifacts. Diverse methods of k-space sampling, imaging sequences, and strategies for image acquisitiontiming have been introduced since its early clinical application. Especially, methods of k-space sampling and image acquisition timing are very important to achieve maximal arterial enhancement and suppress venous signal while maintaining large scan coverage and high spatial resolution. In addition, regardless of several advantages over TOF technique, it still has a tendency to overestimate the degree of stenosis in patients with carotid or vertebralartery disease. In this exhibit, we will overview the current techniques of CE-MRA with special attention to methods of k-space sampling and image acquisition timing. We will also discuss diagnostic accuracy of CE-MRA in patients with supra-aortic cervical artery stenosis and artifacts frequently misinterpreted as steno-occlusive lesion on CE-MRA.
목적 : 고식적인 자기공명혈관조영술 (MR Angiography, MRA) 기법으로는 영상화가 어려웠던 대동맥궁의 주요 분지들의 평가에 있어서 새로운 MR기법인 조영증강 MRA의 임상적 유용성을 알아보고, 그 화질을 사용한 코일의 종류에 따라 비교해 보고자 한다. 대상 및 방법 : 뇌혈관 질환을 의심하여 고식적인 기법으로 뇌 및 경동맥 MRA를 시행한 29명에서 전향적으로 Gd-DAPA 15-20ml를 일시에 손으로 주입한 후 대동맥궁과 그의 주요 분지들에 대해 3시기의 고속 MRA를 시행하여 그 화질을 분석하였다. MRA는 1.0T MR기종에서 3D-FISP기법으로 얻었으며 총 영상 획득 시간은 40-60초였다. 영상 분석은 무명동맥, 양측 총경동맥, 양측 쇄골하동맥과 양측 척추 동맥들의 기시부로부터 전장에 걸쳐 화질을 주관적으로 3등급(good; 명백히 정상소견을 보이는 경우, fair; 약간 낮은 신호를 보이나 정상으로 진단하기에 비교적 만족할 만한 경우, poor; 협착이 모호하거나, 인공물이나 너무 낮은 신호로 혈관을 볼 수 없어 카테터 혈관조영술을 요하는 경우)으로 나누어 평가하였으며, 양측 총경동맥의 분기(bifurcation) 부위에서는 고식적인 기법의 영상과 그 화질을 비교평가하였다. 또한 세가지 사용한 코일의 종류(CP body array 12예, CP neck array 9예, head-and-neck 8예)에 따른 화질 차이를 정성적 및 정량적(신호대 잡음비)으로 분석하였다. 결과 : 대동맥궁 주요 분지들의 전반적인 화질은 55% (16/29)에서 'good', 34%(10/29)에서 'fair'로 평가되어 대부분 고식적인 카테터 혈과조영술이 피요치 않을 정도로 만족할 만한 화질을 보였다. 양측 총경 동맥분지 부위에서는 65%(17/26)에서 고식적인 3D-TOF기법과 같거나 나은 영상을 보였다. CP body array 코일을 사용한 경우가 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 정성적 및 정량적으로 유의하게 나은 영상을 보였다(p<0.05). 결론 : 고속 조영증강 MRA기법은 단시간내 (40-60초)에 대동맥구의 주요 분지들을 그 기시부위부터 두개골 저부에 이르기까지 대부분에서 잘 나타내주므로 선별검사로서 임상적으로 유용하리라 생각되며 CP body array 코일을 사용하였을 경우에 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 좀더 나은 화질을 얻을 수 있으리라 생각된다.
서구화된 식습관, 운동부족, 비만증가 등에 기인한 허혈성 뇌졸중의 급격한 증가로 뇌혈관 협착 또는 폐색의 신속하고 정확한 진단이 매우 중요하다. 뇌혈관을 관찰할 수 있는 기법 중 비 조영 검사인 TOF-MRA 기법은 가장 대표적이고 안정적인 기법이다. 또한 최근 TOF-MRA 혈관영상기법은 CE-MRA 기법에 비해 큰 직경이 아닌 두개 내 혈관과 같은 작은 혈관의 협착 평가에서 유용하다는 평가를 받고 있다. 그러나 TOF-MRA 기법은 뇌 경색의 주요 원인인 플라그 형성에 의한 혈류 역학적인 난류 형성으로 협착 및 폐색의 실제 길이보다 과 측정되는 문제점이 있다. 본 연구의 목적은 유속신호 강조효과를 이용한 TOF-MRA 기법에서 발생하는 플라그 과 측정 오류를 해결하기 위하여 유속신호 감쇄효과를 이용한 3D SPACE T2 시퀀스를 이용, 보다 정확한 협착 및 폐색의 혈관질환 진단을 위한 새로운 시퀀스를 제시하고 난류에 의한 과 측정 원인을 해결하여 임상 활용 가능성을 높이는데 있다. 실험 방법은 플라그 혈관 팬텀을 제작하여 40%, 50%, 60%, 70% 협착을 형성시키고 flow control set를 이용하여 생리식염수로 만든 가상혈류에 0.9ml/sec, 1.5ml/sec, 2.1ml/sec, 2.6ml/sec의 속도 차이를 주어 동일한 조건으로 TOF-MRA 16회, 3D SPACE T2 16회 총 32회를 교차실험 하였고 실제 플라그 길이의 정확도를 비교 실험 하였다. 실험 결과는 각각의 동일한 협착 정도와 혈류 속도의 조건에서 16회의 비교데이터 결과, 새롭게 제안된 SPACE 3D T2 에서 실제 플라그 길이와 유사한 정확도 우위를 보였고, 혈류속도가 빠를수록 그리고 협착 정도가 클수록 TOF-MRA에서 과 측정 오류의 차이가 커짐을 확인 할 수 있었다. 따라서 TOF-MRA에서 발생하는 플라그 과 측정 문제를 해결하고 비 조영 검사인 장점을 유지하기 위해 본 논문에서 제시한 유속신호 감쇄효과를 이용한 3D SPACE T2를 혈관 검사에 사용한다면 보다 정확한 뇌혈관 진단에 큰 도움이 될 것으로 사료된다.
Objectives : The objective of this study was to investigate the role of postoperative three dimensional short-range magnetic resonance angiography(3D-TOF MRA) in predicting the clinical outcomes following microvascular decompression(MVD) for the treatment of a hemifacial spasm(HFS). Material and Method : Postoperative magnetic resonance(MR) imaging was performed on 123 patients with a HFS between March 1999 and May 2000. All patients who had postoperative MR imaging were undertaken preoperative MR imaging. Of the 123 patients, 122 patients were included in this retrospective study. The degree of the detachment of vascular contact, and change of the position of offender were determined by pre- and postoperative 3D-TOF MRA. These findings were compared with the surgical findings and clinical outcomes. Results : Of 122 patients who had successful MVD, clear decompression of offenders of the root entry zone(REZ) of facial nerve was found in 106 patients(86.9%), partial decompression in 10 patients(8.2%) and contact of offenders to the REZ of facial nerve in 6 patients(4.9%) by the postoperative 3D-TOF MRA. Our patients demonstrated that the types of offender did not influence with the degree of decompression of REZ of facial nerve and with surgical outcomes(p>0.05). Also, there was no significant relationship between the degree of decompression of the REZ of facial nerve from offenders and an improvement of symptoms(p>0.05). Futhermore, there was no significant relationship between the degree of decompression of the REZ of facial nerve from offenders and an improvement time (p>0.05). Conclusion : Our data suggests that MVD of facial nerve alone may not be sufficient to resolve the symptoms in all patients with hemifacial spasm. Therefore, another unknown factors besides vascular compression may be involved to cause symptoms in certain patients and it may be necessary to remove these factors with MVD simultaneously to obtain the resolution of symptom.
The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.
We have designed ramp profile excitation pulse based on the Shinnar-Le Roux (SLR) algorithm. The algorithm provides many advantages to pulse designers. The first advantage is the freedom of deciding the amplitudes, frequencies, and ripple sizes of stopband, passband, and transition band of pulse profile. The second advantage is the freedom of deciding the pulse phase, more specifically, minimum phase, linear phase, maximum phase, and any phase between them. The minimum phase pulse is the best choice in the case of 3D TOF, because it minimizes the echo time, which implies the best image quality in the same MR examination condition. In addition, the half echo technique is slightly modified in our case. In general, using the half echo technique means that the acquired data size is half and the rest part can be filled with complex conjugate of acquired data. But in our case, the echo center is just shifted to left, which implies the reduction of echo time, and the acquired data size is the same as the one without using the half echo technique. In this case, the increase of right part of data leads to improvement of the resolution and the decrease of left part of data leads to decrease of signal to noise ratio. Since in the case of 3D TOF, the signal to noise ratio is sufficiently high and the resolution is more important than signal to noise ratio, the proposed method appears to be significantly affective and gives rise to the improved high resolution angiograms.
일반적으로 MR Angiography(MRI)는 사전 포화방법(presaturation)을 이용하여 동맥과 정맥의 분리된 영상을 획득한다. 하지만 이러한 일반적인 사전포화방법으로 동맥과 정맥영상을 획득하기 위해서는 두 번의 영상획득이 필요하다. 따라서 본 연구에서는 동맥과 정맥의 구분된 영상을 한번의 영상획득으로 얻을 수 있는 SAAV 기법을 0.3T MRI system에 적용하고, 획득한 동맥과 정맥의 두 MRA 영상을 Colot-Mapping으로 동$.$정맥을 한 영상에 구분하여 나타냄으로써 0.3T MRI system에서 MRI의 임상적 적용 및 활용 가능성을 높이고자 하였다. 마산 삼성병원의 0.3T MRI system (Magfinder, AILab. Korea)어서 SAAV sequence를 이용하여 정상적인 피험자로부터 목 부위의 동맥과 정맥 혈관영상 (volume : 256${\times}$256${\times}$64)을 동시에 얻었다. 그리고. 이들의 각 2D 영상들에서 위치정보를 획득한 후 MIP 기법과 Color Mapping으로 조합하여 3D Artery-Vein Color Mapping(AVCM) MRA 영상으로 재구성하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.