A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique-

뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 -

  • Choi, Sung-Hyun (Department of Radiology, Kyung Hee University Hospital at Gang-dong) ;
  • Goo, Eun-Hoe (Department of Electronics and Communications Engineering, Gwangwoon University) ;
  • Hwang, Sun-Kwang (Department of Radiology, Kyung Hee University Hospital at Gang-dong) ;
  • Lee, Gang-Won (Department of Radiology, Kyung Hee University Hospital at Gang-dong) ;
  • Lee, Jong-Woong (Department of Radiology, Kyung Hee University Hospital at Gang-dong)
  • 최성현 (강동경희대학교병원 영상의학과) ;
  • 구은회 (서울대학교병원 영상의학과) ;
  • 황선광 (강동경희대학교병원 영상의학과) ;
  • 이강원 (강동경희대학교병원 영상의학과) ;
  • 이종웅 (강동경희대학교병원 영상의학과)
  • Received : 2012.01.15
  • Accepted : 2012.03.05
  • Published : 2012.03.31

Abstract

The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.