• Title/Summary/Keyword: TOC removal

Search Result 217, Processing Time 0.021 seconds

Effect of powder activated carbon replacement on HCPAC-MBR system operation (고농도 분말활성탄 결합 MBR 운전에 대한 활성탄 교체주기의 영향)

  • Lee, Chae-Ha;Kim, Jin-Tae;Lee, Jung-Hyun;Seo, Gyu-Tae;Kim, In S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This study was conducted to evaluate the effect of PAC(Powder Activated Carbon) retention time on stable operation of high concentration powered activated carbon(HCPAC-MBR) in the treatment of secondary domestic wastewater. The pilot scale HCPAC-MBR system was operated at two different SRTs, 25 days and 100 days. The main drawback of HCPAC-MBR system was the rapid increase of trans-membrane pressure. The increase rate of trans-membrane pressure was proportional to SRT value at constant flux. This result seemed to be caused by reduced amount of EPS adsorbed on the PAC in the reactor by decreasing the SRT of the PAC. The particle size of the PAC was also influenced by SRT. The PAC size was decreased as SRT was increased. The change of particle size could be one reason for the change of trans-membrane pressure. The pore volume in the cake-layer formed on the membrane surface became to be increased by reducing SRT, because the cake-layer was highly composed of the PAC. Therefore, increased pore volume might play a role to reduce the trans-membrane pressure. The removal rate of E260 and TOC was also inversely proportional to SRT value.

Treatment Characteristics of Sand Filtration and Microfiltration (MF) in Advanced Water Treatment (고도정수처리에서 사여과와 정밀여과의 유기물처리특성에 관한 연구)

  • Kim, Hyung-Suk;Lee, Byoung-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.723-734
    • /
    • 2010
  • With a belief of high water quality production and less chemical usage, membrane technology including Microfiltration (MF), Ultrafiltration (UF), and Nanofiltration(NF) is being employed more and more in drinking water treatment process. However, due to higher energy consumption of UF and NF, MF is normally used for drinking water treatment especially in a plant of large scale. In this investigation, performance ofsand filtration and membrane filtration was compared regarding removal of various water quality parameters, such as TOC, DOC, KMnO4 consumption, THMFP, and HAAFP. Two lines of pilot plant have been operated, one of which line is a traditional advanced water treatment process which includes sedimentation, sand filtration, ozonation, and activated carbon, and the other line is an alternative treatment process which includes sedimentation with inclined plate, MF membrane, ozonation, and activated carbon. For the first about 4months of period, MF filtration showed similar or little bit higher performance than sand filtration. However, after about 4month later, sand filtration showed much higher performance in removing all parameters monitored in the investigation. It was found that sand filtration is a better option than MF filtration as far as microbial community is fully activated in sand filter bed.

Characteristics of Membrane Fouling and Nitrification in Nitrifying Membrane Bioreactor (Nitrifying membrane bioreactor에서의 막 오염 및 질산화 특성)

  • Lim, Kyoung-Jo;Hong, Soon-Ho;Yoo, Ik-Keun
    • Journal of Environmental Science International
    • /
    • v.20 no.9
    • /
    • pp.1079-1085
    • /
    • 2011
  • The purpose of this study is to find the operational characteristics of nitrifier-dominated membrane bioreactor (MBR), which has been extensively studied for organic removal, especially in terms of nitrite ($NO_2$-N) build-up and membrane fouling. Membrane fouling is one of the important factor which determines the economics of MBR system. The characteristics of membrane fouling was monitored in terms of the fouling indices such as sludge volume index (SVI), the concentration of total organic carbon (TOC) and extracellular polymeric substances (EPS) in a membrane permeate or sludge extract, the absorbance of supernatant at 260 nm. Most of index values except for protein concentration in EPS had a close relation with the increase of suction pressure and SVI value. Nitrifying MBR was superior to the conventional organic-oxidizing MBR in terms of membrane fouling since the fouling index value of nitrifying MBR was lower than that of BOD-oxidizing MBR.

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

Degradation of p-nitrophenol by Gamma Irradiation

  • Lee, O Mi;Kim, Tae-Hun;Yu, Seungho;Jung, In-ha;Lee, Myunjoo
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.353-357
    • /
    • 2011
  • Degradation of p-nitrophenol has been carried out using only gamma irradiation or gamma irradiation with $H_2O_2$ or $Na_2S_2O_8$. Effects of different operating parameters such as initial concentration ($50mg\;l^{-1}$, $100mg\;l^{-1}$, $200mg\;l^{-1}$, $300mg\;l^{-1}$, $400mg\;l^{-1}$, $500mg\;l^{-1}$ and $600mg\;l^{-1}$) on the extent of degradation has been investigated. At 5 kGy, $50mg\;l^{-1}$ p-nitrophenol was completely degraded, and the radiolytic degradation of p-nitrophenol was described by the pseudo-first-order kinetic model. The combination of gamma irradiation with $H_2O_2$ or $Na_2S_2O_8$ leads to an enhanced effect, which remarkably increased the degradation efficiency of p-nitrophenol and TOC removal. However, at high $H_2O_2$ concentration, the efficacy of p-nitrophenol degradation is reduced because ${\cdot}OH$ radicals are scavenged by $H_2O_2$ and $Na_2S_2O_8$.

Effects of Aerobic Granular Sludge Separator on the Stability of Aerobic Granular Sludge (AGS) (호기성 그래뉼 슬러지 선별 분리기가 호기성 그래뉼 슬러지의 안정성에 미치는 영향)

  • Kwon, Gyutae;Kim, Hyun-Gu;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.30 no.12
    • /
    • pp.1081-1092
    • /
    • 2021
  • In this study, the effect on the stability of Aerobic Granular Sludge (AGS) caused by an AGS separator was investigated. The AGS separator was a hydrocyclone. The main factors of the AGS separator were filter pore size (0.125~0.600 mm), conical-to-cylindrical ratio (1.5~3.0), and operating time (1~20 min). The AGS/mixed liquor suspended solid (MLSS) ratio gradually increased to 0.500 mm (AGS/MLSS: 84.3±3.0%). AGS was best separated at the conical-to-cylindrical ratio of 2.5 (AGS/MLSS: 84.7±3.3%). As the operating time increased, the AGS separation performance also tended to increase. The shortest AGS separator run time, but the highest AGS separation performance was 10 min (87.0±2.5%). AGS stability was evaluated by operating the selected AGS separator and sequencing batch reactor. The average removal efficiencies of TOC, TCODCr, SS, TN, and TP were 95.7%, 96.9%, 93.0%, 89.0%, and 96.2%, respectively, which met the effluent standards in Korea. In addition, the AGS/MLSS ratio tended to remain constant, and the sludge volume index demonstrated a tendency to decrease from 140 mL/g to 70 mL/g. During the operation, the particles of AGS in optical microscope observations gradually increased.

Fenton Oxidation of Landfill Leachate by $Fe^0,\;Fe^{2+},\;Fe^{3+}\;/\;H_2O_2$ Systems ($Fe^0$, $Fe^{2+}$, $Fe^{3+}$ / $H_2O_2$ 시스템을 이용한 침출수의 Fenton 산화반응)

  • Park, Sung-Ho;Han, Ihn-Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.4
    • /
    • pp.402-408
    • /
    • 2005
  • This investigation aimed at selecting the optimum catalyst and reaction conditions used in Fenton oxidation for landfill leachate treatment and was carried out at ambient temperature using a lab-scale experiment. The investigation led to the following results: 1) The optimum pH and dose for each iron catalyst were as follows: $Fe^{2+}\;=\;1,200\;mg/L$, $H_2O_2\;=\;1,200\;mg/L$, initial pH=3.0; $Fe^{3+}\;=\;1,200\;mg/L$, $H_2O_2\;=\;1,500\;mg/L$, initial pH=4.5; $Fe^0\;=\;1,200\;mg/L$, $H_2O_2\;=\;900\;mg/L$, initial pH=4.0, respectively. 2) The progress of Fenton oxidation could be instrumentally monitored by measuring redox potential evolution during leachate oxidation, thus, indicating the possibility of an on-line process monitoring. 3) A simple acid-base titration of Fenton-treated leachate proved that a relevant fraction of by- products formed during the treatment was made of acidic compounds in the optimum reaction condition for each catalyst used, thus demonstrating that the higher the extent of Fenton oxidation the greater was the amount of acids formed. 4) With the aim of selecting the optimum catalyst among $Fe^0$, $Fe^{2+}$ and $Fe^{3+}$, removal efficiency of each parameter in the optimum reaction conditions was considered. Although $Fe^{3+}$ was higher than other catalysts($Fe^0$, $Fe^{2+}$) in removal efficiency, $Fe^0$ was a optimum catalyst with a view of cost effectiveness.

Degradation Characteristics of Non-degradable Dye in Aqueous Solution by Ozonation (고도산화공정인 오존처리에 의한 난분해성 염료 수용액의 분해특성)

  • Hwang, Se-Wook;Park, Jong-Hwan;Lee, Su-Lim;Eom, Ju-Hyun;Ryu, Sung-Ki;Choi, Ik-Won;Kim, Seong-Heon;Kang, Se-Won;Cho, Ju-Sik;Seo, Dong-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.58-64
    • /
    • 2020
  • BACKGROUND: Most of the researches on the dye removal using ozonation have been focused on the removal efficiency. However, the research on their removal characteristics and mechanism according to the reaction time has been still insufficient. METHODS AND RESULTS: In this study, the effects of initial pH and dye concentration with reaction time on the degradation characteristics of methyl orange (MO) and methylene blue (MB) by ozonation were evaluated. The degradation efficiency of MB by ozonation increased with increasing pH. On the other hand, the degradation efficiency of MO by ozonation did not show a significant difference with varing pH. The both MO and MB by ozonation were decomposed within 30 min irrespective of the dye concentration, but the decomposition rates of dyes were faster at lower initial dye concentration. The decomposition efficiency of total organic carbon (TOC) in each dye solution by ozonation was low, which was found to be effective for partial decomposition such as decolorization rather than complete degradation of the dye. CONCLUSION: Overall, ozonation was an effective method for removing nondegradable dyes. However, it is necessary to study the optimization of dye degradation under various environmental conditions for ozonation.

Catalytic Ozonation of Phenol (페놀의 촉매오존산화 반응에 관한 연구)

  • Lee, Cheal-Gyu;Woo, Jeong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.731-738
    • /
    • 2011
  • In this study AOPs of $O_3/UV$ radiation, $O_3/Mg(OH)_2/UV$ radiation and $O_3/MgO/UV$ radiation system for phenol treatment in aqueous solution was performed in a laboratory scale circulating batch reacter. Flow rate of ozone 1.0 L/min, ozone concentrations $150{\pm}10mg/L$ was maintained constantly at the above-mentioned oxidation processes. During the oxidation processes the $COD_{Cr}$ and TOC was measured in the composition. The pseudo first-order rate constants of the processes was $5.12{\times}10^{-5}$, $1.19{\times}10^{-4}$ and $1.79{\times}10^{-4}sec^{-1}$, and the activation energy was 3.03, 1.79 and $2.32kcal{\cdot}mol^{-1}$ at $20^{\circ}C$, respectively. It was found that both $Mg(OH)_2$ and MgO had remarkable accelerations on degradation of phenol and removal of COD in water. On this basis, $O_3/MgO/UV$ system is an effective and feasible routes for catalytic ozonation of phenol in water.

Effects of Operating Parameters on Phenol Degradation by Pulsed Corona Discharges in Aqueous Solutions (펄스 코로나 방전에 의한 페놀 분해에 미치는 운전변수의 영향)

  • Chung, Jae-Woo;Moon, Ji-Hoon;Park, Eun-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.79-86
    • /
    • 2010
  • Effects of operating parameters such as applied voltage, solution conductivity, ferrous ion concentration, electrode material on phenol degradation by pulsed corona discharges were investigated in laboratory scale experiments. The increase of applied voltage enhanced the phenol degradation by generating more energetic electrons. The solution conductivity inversely affected phenol removal rate in the tested ranges because the increase of conductivity decreased the electric field strength through the liquid phase. The addition of ferrous sulfate promoted the phenol degradation through the OH radical production by the Fentonlike reactions between ferrous ion and hydrogen peroxide generated by pulsed corona discharges. Catechol and hydroquinone were detected as primary intermediates of phenol degradation and the decrease of pH and the increase of conductivity were observed probably due to the generation of organic acids. Almost all of the initial phenol was disappeared and 29% of total organic corbon (TOC) was removed in the condition of 0.5 mM of ferrous sulfate after approximately 230 kJ of discharge energy transferred to the reactor.