• Title/Summary/Keyword: TOA

Search Result 248, Processing Time 0.026 seconds

Pulse Position Determination using Adaptive Threshold Detector (Adaptive Threshold Detector를 이용한 펄스 위치 계산)

  • Chagn, Jae-won;Lee, Sang Jeong
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.2
    • /
    • pp.163-170
    • /
    • 2017
  • MLAT which is an independent cooperative surveillance system is applied to increase the positon resoultin of secondary survelliance radar. MLAT uses the hyperboic or hyperboloid position mesurement algorithm. Central processing unit of MLAT calculates target position using time difference of arrival (TDOA) which can be solved from time of arrival (TOA) information of each receivers (at least 4 receivers). To increase position resolution of MLAT which use TDOA, TOA which is transfer time from tranmitter to receiver shold be calculated with precision time resolution in receiver. This paper explained the MLAT system briefly and explained ATD which is one of means of calcuating pulse position. ATD is applied to solve the deviation of pulse position due to different amplitude of signals in mulitiple receivers. In this paper, to analysis the performance of ATD, the simulation result of LAS and CDS was compared with the simulation result of basic threshold method.

Analysis of PRI Pattern with the Second Deviation of LASER Pulse Train (레이저 펄스열의 2차 차분을 이용한 PRI 패턴 분석)

  • Lim, Joong-Soo;Hong, Kyung-Ho;Jun, Gab-Song;Moon, Sung-Chul;Lee, Chang-Jae;Suh, Suhk-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.4
    • /
    • pp.63-70
    • /
    • 2008
  • This paper presents a method of PRI do-interleaving for LASER pulse signals. When the PRI of LASER pulse is periodically changed, the first deviation and the second deviation of TOA is used to calculate the PRI pattern of input LASER signals of receiver. If the standard deviation of the first difference of TOA is less than 5% of the average of the first difference of TOA, the PRI pattern of LASER signal is fixed or jittered type. If the standard deviation is larger than 5% of the average, those are triangular PRI patterns or sawtooth PRI patterns.

Accuracy Comparison of TOA and TOC Reflectance Products of KOMPSAT-3, WorldView-2 and Pléiades-1A Image Sets Using RadCalNet BTCN and BSCN Data

  • Kim, Kwangseob;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.1
    • /
    • pp.21-32
    • /
    • 2022
  • The importance of the classical theme of how the Top-of-Atmosphere (TOA) and Top-of-Canopy (TOC) reflectance of high-resolution satellite images match the actual atmospheric reflectance and surface reflectance has been emphasized. Based on the Radiometric Calibration Network (RadCalNet) BTCN and BSCN data, this study compared the accuracy of TOA and TOC reflectance products of the currently available optical satellites, including KOMPSAT-3, WorldView-2, and Pléiades-1A image sets calculated using the absolute atmospheric correction function of the Orfeo Toolbox (OTB) tool. The comparison experiment used data in 2018 and 2019, and the Landsat-8 image sets from the same period were applied together. The experiment results showed that the product of TOA and TOC reflectance obtained from the three sets of images were highly consistent with RadCalNet data. It implies that any imagery may be applied when high-resolution reflectance products are required for a certain application. Meanwhile, the processed results of the OTB tool and those by the Apparent Reflection method of another tool for WorldView-2 images were nearly identical. However, in some cases, the reflectance products of Landsat-8 images provided by USGS sometimes showed relatively low consistency than those computed by the OTB tool, with the reference of RadCalNet BTCN and BSCN data. Continuous experiments on active vegetation areas in addition to the RadCalNet sites are necessary to obtain generalized results.

Predispersed Solvent Extraction of Succinic Acid Aqueous Solution by Colloidal Liquid Aphrons in Column

  • Kim Bong Seock;Hong Yeon Ki;Huh Yun Suk;Hong Won Hi
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.454-458
    • /
    • 2004
  • A study of the POSE (predispersed solvent extraction) for succinic acid by colloidalliq­uid aphrons was conducted. The organic phase contaning TOA (tri-n-octylamine) and 1-octanol permits a selective extraction of succinic acid from its aqueous solution. There was no difference of the extractability of POSE and that of conventional mixer-settler type extraction. Taking into account the no mechanical mixing in POSE, it was concluded that the POSE process is more adaptive than the conventional mixer-settler type extraction process. From mass transfer analysis at the various concentration of TOA in counter-current continuous operation, the concentration of TOA had no influence on the mass transfer coefficient. The loading values in continuous POSE were almost same as those in batch operation.

Method for Feature Extraction of Radar Full Pulses Based on EMD and Chaos Detection

  • Guo, Qiang;Nan, Pulong
    • Journal of Communications and Networks
    • /
    • v.16 no.1
    • /
    • pp.92-97
    • /
    • 2014
  • A novel method for extracting frequency slippage signal from radar full pulse sequence is presented. For the radar full pulse sequence received by radar interception receiver, radio frequency (RF) and time of arrival (TOA) of all pulses constitute a two-dimensional information sequence. In a complex and intensive electromagnetic environment, the TOA of pulses is distributed unevenly, randomly, and in a nonstationary manner, preventing existing methods from directly analyzing such time series and effectively extracting certain signal features. This work applies Gaussian noise insertion and structure function to the TOA-RF information sequence respectively such that the equalization of time intervals and correlation processing are accomplished. The components with different frequencies in structure function series are separated using empirical mode decomposition. Additionally, a chaos detection model based on the Duffing equation is introduced to determine the useful component and extract the changing features of RF. Experimental results indicate that the proposed methodology can successfully extract the slippage signal effectively in the case that multiple radar pulse sequences overlap.

ABSOLUTE RADIOMETRIC CALIBRATION OF 1M SATELLITE IMAGERY

  • Lee Sun-Gu;Lee Dong-han;Seo Doo-chun;Song Jeong Heon;Kim Yongseung;Paik Hongyul
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.616-619
    • /
    • 2005
  • CALNAL team of Korea Aerospace Research Institute(KARI) performed field campaigns for absolute radiometric calibration of 1m satellite image on Daejeon and the cal/val site of Goheung. The satellite image have spatial resolution of 1m in panchromatic spectral band of 450-900nm. The performed cal/val method is the reflectance-based of vicarious calibration methods. We collected ground-based and meteology data such as temperature, surface pressure and reflectance of targets, and radiosonde data used only to test in Goheung. Data collected on each field served as input to radiative transfer codes to generate a top-of-atmosphere(TOA) radiance estimate. Derived TOA is compared with DN of overpass satellite to calculate calibration coefficient of gain and offset.

  • PDF

Localization of an Underwater Robot Using Acoustic Signal (음향 신호를 이용한 수중로봇의 위치추정)

  • Kim, Tae Gyun;Ko, Nak Yong
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.231-242
    • /
    • 2012
  • This paper proposes particle filter(PF) method using acoustic signal for localization of an underwater robot. The method uses time of arrival(TOA) or time difference of arrival(TDOA) of acoustic signals from beacons whose locations are known. An experiment in towing tank uses TOA information. Simulation uses TDOA information and it reveals dependency of the localization performance on the uncertainty of robot motion and senor data. Also, comparison of the PF method with the least squares method of spherical interpolation(SI) and spherical intersection(SX) is provided. Since PF uses TOA or TDOA which comes from measurement of external information as well as internal motion information, its estimation is more accurate and robust to the sensor and motion uncertainty than the least squares methods.

A Performance Comparison of Positioning Methods Considering Measurement Noise (측정 잡음을 고려한 위치 결정 기법의 성능비교)

  • Park, Chan-Sik;Yim, Jae-Geol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1176-1181
    • /
    • 2010
  • This paper proposes three positioning algorithms using TOA measurements: 1) The well-known linearization method using Taylor series, 2) a modified Savarese method considering measurement noise, which does not need linearization, and 3) a modified Bancroft method where TOA measurements instead of pseudorange measurements are considered. Furthermore, through an error analysis, for Savarese method, divergence of altitude is anticipated if the transmitters are located at the same height. To prevent height divergence, the Savarese method is modified again for receivers which assumed moving on the even plane. Error analysis also shows the relationship between Bancroft and Savarese method. From the analysis it is expected that the performance of Savarese method is worse than Bancroft method because of error amplification during difference operation. Experiments using real TOA measurement from the time difference of ultra sound and RF validate the proposed methods and show that analysis is correct.

A Study on the efficient management plan of National control points (효율적인 국가기준점 관리방안에 관한 연구 - TOA 방식을 이용한 기준점 모니터링 -)

  • 이재원;조흥묵;유수엽;이석용
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.551-555
    • /
    • 2004
  • 본 연구는 건설교통기술혁신 사업의 일환으로 '국가기준점의 관리 및 위치정보서비스 제공을 위한 전자표지석 개발' 과제에 관한 연구내용 및 결과를 중심으로 하고 있으며, 주 내용은 2차 년도 연구에서 수행한 TOA(Time Of Arrive) 방식을 적용한 전자표지석 개발에 관한 것이다. 본 연구의 궁극적인 목적은 국가기준점을 효율적으로 관리하기 위한 새로운 방안을 제시하는 것으로, 기준점의 현황을 실시간 모니터링하고 기준점의 위치파악을 용이하게 할 수 있는 시스템을 연구하는 것이다. 이를 위해 기준점의 현황을 모니터링 가능하도록 기준점의 움직임을 파악할 수 있는 센서를 부착하였고, 편리한 기준점 위치파악을 위하여 TOA(Time Of Arrive) 방식을 적용한 전자표지석의 설계 및 시제품을 제작하였다. 연구결과를 기준점 관리에 활용하기 위한 시제품을 개발하였다.

  • PDF

Analysis of TDOA and TDOA/SS Based Geolocation Techniques in a Non-Line-of-Sight Environment

  • Huang, Jiyan;Wan, Qun
    • Journal of Communications and Networks
    • /
    • v.14 no.5
    • /
    • pp.533-539
    • /
    • 2012
  • The performance analysis of wireless geolocation in a non-line-of-sight (NLOS) environment is a very important issue. Since Cramer-Rao lower bound (CRLB) determines the physical impossibility of the variance of an unbiased estimator being less than the bound, many studies presented the performance analysis in terms of CRLB. Several CRLBs for time-of-arrival (TOA), pseudo-range TOA, angle-of-arrival (AOA), and signal strength (SS) based positioning methods have been derived for NLOS environment. However, the performance analysis of time difference of arrival (TDOA) and TDOA/SS based geolocation techniques in a NLOS environment is still an opening issue. This paper derives the CRLBs of TDOA and TDOA/SS based positioning methods for NLOS environment. In addition, theoretical analysis proves that the derived CRLB for TDOA is the same as that of pseudo-range TOA and the TDOA/SS scheme has a lower CRLB than the TDOA (or SS) scheme.