• 제목/요약/키워드: TLD

검색결과 362건 처리시간 0.024초

사고시 대응 정밀 베타선량계 개발 (Development of Precise Beta Dosimeter)

  • 이원근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.468-470
    • /
    • 1996
  • The use of thermoluminescent dosimeters (TLDs) for beta dosimetry has been encumbered by the energy-dependent responses of TLDs to beta radiation. This energy-dependent response is due to the low penetrating ability of beta particles. Thus the determination of the beta dose imparted to an exposed TLD chip can be accurately determined only if the energy distribution of beta radiation is correctly accounted for. So precise beta dosimeter used TLD chips place under several aluminum filters of varying thicknesses and developed to correctly determine doses due to radiation fields where the beta energy distribution is unknown.

  • PDF

방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가 (Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter)

  • 강인석;안성민
    • 한국콘텐츠학회논문지
    • /
    • 제14권11호
    • /
    • pp.864-870
    • /
    • 2014
  • 선량계 유용성을 평가하기 위한 방법으로 방사선관계종사자의 피폭선량을 측정하여 개인피폭관리를 위한 선량계 선택의 기초 자료를 제시하고자 하였다. 2012년 1년간 방사선사 30명을 대상으로 하였으며 개인피폭 누적선량을 측정하여 열형광선량계, 형광유리선량계, 광자극발광선량계의 성능을 조사하였다. 연구방법으로는 DAP와 ion-chamber를 이용하여 세종류 개인피폭선량계의 선량측정값을 비교 분석하였으며 의료기관별, 검사업무별, 분기별 방사선관계종사자의 피폭누적선량을 확인하였다. 결과적으로 직접 X선조사를 통한 개인피폭선량계의 선량값과 ion-chamber의 절대값에서 광자극발광선량계가 열형광선량계나 형광유리선량계에 비해 더 유사한 선량값을 나타내 측정 능력면에서 더 우수한 결과를 나타냈다. 또한 방사선발생구역에서 방사선관계종사자의 피폭선량이 광자극발광선량계에서 보다 높게 나타났다.

전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정 (The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.149-154
    • /
    • 1991
  • 안과용 $^{90}$ Sr 선원에서 방출하는 $\beta$선의 갯수를 직접 측정함으로써 (전류 측정)표면 선량을 계산하는 방법을 고안하여 실제 교정에 응용하였다. 안과용 $^{90}$ Sr선원에서 방출하는 전체 $\beta$선의 갯수 및 선원의 면적, 전자의 물속에서의 저지능 등을 고려하였다. 선원의 정확한 면적 측정은 필림을 이용하였으며, 평균 저지능은 상기 선원에서 방출되는 $\beta$선의 에너지 스펙트럼을 분석함으로써 얻을 수 있었다. 이 방법과 $^{90}$ Sr으로 교정한 TLD칩을 이용한 교정 방법과의 결과를 비교하였다. 전류 측정 방식에 의한 결과는 63.5$\pm$5.1cGy/sec이었고, TLD칩에 의한 측정 결과는 50.7$\pm$7.3cGy/sec로 오차 범위내에서 일치하였다. 그러나 제작사 보증서에 의하면 46.8$\pm$9.4cGy/sec로 측정값에 비하여 36%의 차이를 보여 주었다.

  • PDF

Gamma-ray Dose Measurements in a Human Phantom Using Thermoluminescent Dosimeter

  • Yoo, Young-Soo;Lee, Hyun-Duk
    • Nuclear Engineering and Technology
    • /
    • 제6권4호
    • /
    • pp.239-247
    • /
    • 1974
  • 방사선 안전관리의 효과적인 연구를 위해 유사인체 모형을 설계, 제작하였다. 이 모형의 치수는 한국인의 체격과 근사하게 맞추었으며 두께 2.5cm인 포리에칠렌판 35매로 구성되었다. 유사인체모형의 표면에 착용한 열형광 설량계(Disc type TLD)로써 외부 ${\gamma}$-방사선에 의한 신체특정부위의 피폭선량을 측정하였으며, 아울러 깊이에 따른 흡수선량에 대해서 열형광 선량계(micro rod type TLD)로써 측정하여 결정장기 부위의 각단면에 대한 등가선량선을 얻었다. 선량측정은 방사선 작업자의 작업환경조건에 유사하도록 유사인체 모형에 대해 배치하고 여러 입사방항에 대해서 실시하였다. 그 결과 Cs-137, ${\gamma}$-방사선에 대하여 두께 20cm인 유사인체 모형에서의 감쇄는 0.439였으며 이는 보고된 자료들과 잘 일치하였다.

  • PDF

The Usefulness of Bolus of Radiation Therapy in Patients with Whole Breast Cancer

  • Min, Jung-Whan;Son, Jin-Hyun;Park, Hoon-Hee;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.99-103
    • /
    • 2011
  • Radiation Therapy has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internam mammary nodes and supraclavicular nodes. The purpose of this study is treated breast cancer patient to use 6 MV, 10 MV with bolus so that we observe changing of skin dose and evaluate those usefulness. Using woman's phantom, after CT simulate scanning, Through RTP system to make treatment plan, select three any place. And then, we measure that dose rate. After moving the phantom to linac, we put for TLD to three point same as RTP system which we put on the phantom. We exposed 6 MV, 10 MV with bolus and without so that it is measured dose by TLD device(4000 Harshaw). As a reult expose 6 MV,10 MV, it differences 10%, 15% according to bolus and withoout bolus where lateral point from RAO, LPO beam, other one is 20% where the furthest from both beams. To use bolus in the hospital is material to include closely part at skin among tissue of breast cancer. Acquired skin dose from RTP system is uncertainity. So it has to test another system likely TLD or other dosimetry system. Also exposed field of breast cancer is included inhomogeneity such as lung, bone and so on. Therefore it has to be accomplished a dose calculating of inhomogeneity part from treatment plan.

  • PDF

6 MV X-선 조사시 중두개와에서의 선량감쇠 (Dose Attenuation in the Mid-Cranial Fossa with 6 MV Photon Beam Irradiations)

  • 박정호;최태진;김옥배
    • Radiation Oncology Journal
    • /
    • 제8권1호
    • /
    • pp.125-131
    • /
    • 1990
  • 방사선조사시 선량분포에 영향을 미치는 여러가지 요소들 중에서 조직불균등성은 선량을 상당히 변화시킨다. 특히, 중뇌강은 여러골조직으로 구성되어 있어 조직 불균등성에 따른 상당한 선랑감쇠가 예상된다. 6 MV X-선 조사후 중두개와에서의 선량분포측정은 LiF TLD 소자를 이용하였으며 같은 측정장소에서, 계산에 의한 예상선량과 실측선량의 비교를 시도하였다. 계산에 의하면, 골조직 1 cm당 예상선량감쇠는 $3.74\%$를 나타내었다. 한편, 골조직을 고려한 예상선량과 실측선량의 차이는 매우 적었으며 $\pm0.21\%$의 오차범위내에서 일치됨을 나타내었다.

  • PDF

2014 브라질 회의로 가는 길 (A Glimpse into Brazil Conference)

  • 전응휘
    • 인터넷정보학회지
    • /
    • 제14권4호
    • /
    • pp.63-76
    • /
    • 2013
  • This short report introduces the general background why Brazil conference is being prepared and what topics would be undertaken and what goals are being taken into account. It overviews what differences from traditional telecommunication governance, internet governance has had in its historical development and how such differences had been formed from its technological differences and the regulatory policy shift from common carrier regulation to privatization. Moreover, the fact that open, voluntary, bottom-up, diverse stakeholder's participation had evolved throughout the historical development of the internet, had established the present multistakeholder governance model from technological standardization to addressing scheme policies. ICANN, which has governed internet addressing schemes since the earlier 2000s, had developed address policies including IANA function from Jon Postel and technical community's legacy management system into contract based formation between ICANN and gTLD, ccTLD registries. And it made dispute resolution policies responding to trademark disputes and resolved gTLD monopoly issue by introducing new TLD generation and the separation of registry and registar. However, there had been challenges on the legitimacy of ICANN due to its dependency on the Federal Government of the U.S. particularly in its oversight role over ICANN and IANA contract. WSIS raised up internet governance issues including addressing governance, and set up IGF as a discussion platform for multistakeholders to discuss and share all views on other internet related public policies. IGF's loose and non-binding discussion once frustrated governments and other stakeholders, but more focused discussion and visible outcomes have consolidated its unique role for internet governance discourses. Particularly, IGF addressed many emerging internet related issues like cybersecurity, privacy, net neuratlity, development related issues. WTPF of 2013, after WCIT debate on whether traditional telecommunication regulation could be applied to internet infrastructure, suggested other governance issues such as the transition to ipv6, IXP coordination etc. How to make sure the legitimacy of internet addressing governance and how and where other internet related public policies could be undertaken are fundamental tasks for internet governance. Brazil conference, which has been motivated by the breakdown of trust in internet governance from NSA mass surveillance revealed by Snowden, faces these questions and try to make consensus on principles, institutions and roadmap for internet governance in multistakeholder participation way.

  • PDF

TLD를 이용한 X-선 수중 흡수선량 측정 및 해석 (Measurement and Analysis of X-ray Absorbed Dose in Water Phantom using TLD)

  • 오장진;전재식;하석호;김원식;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제13권2호
    • /
    • pp.21-28
    • /
    • 1988
  • LiF : PTEE를 사용하여 중경 X-선(HVL : 0,29, 0.84, 1.60, 2.62mmCu) 영역에 대한 수중 흡수선량을 측정 해석하였다. 이때 선량계 (0.4mm ${\times}\;{\phi}$12.5mm, hot-pressed LiF TLD-700)는 루사이트로 둘러 싸여 있고 물의 흡수선량은 각각의 TL출력 값에 Burlin의 공동이론을 적용하여 해석하였다. 그 결과 물 팬텀 속 깊이 5cm에서 흡수선량률의 측정 오차는 최대 ${\pm}5%$로 나타났다. 이 측정값을 측정 오차가 ${\pm}2%$의 간접절대측정방법인 이온화법에 의한 측정값과 비교한 결과 두 값의 차이는 LiF : PTFE의 측정오차 범위 내에서 일치하였다. 이와같은 결과로 LiF : PTFE를 이용한 수중 흡수선량 측정의 신뢰성을 확인할 수 있게 되었으며 이는 중경 X-선 영역에 대한 선량당량 평가의 근거로 활용 될 수 있을 것이다.

  • PDF

전립선암의 세기조절 방사선치료 시 불균질부에 의한 선량변화에 관한 고찰 (The Investigation Regarding the Dose Change due to the Heterogeneity of Prostate Cancer Treatment with IMRT)

  • 윤일규;박장필;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.107-112
    • /
    • 2007
  • 목 적: 본원에서 시행하고 있는 전립선암의 세기조절 방사선치료시 직장 내에 존재하는 불균질부에 의한 선량변화를 전산화 치료계획 선량과 자체 제작한 전립선암 환자형 골반 팬톰을 이용하여 측정한 선량을 비교하고자 한다. 대상 및 방법: 전립선암 환자형 골반 팬톰(타원형의 물 팬톰: $30\times20\times20cm^3$, 방광, 직장, 정낭을 묘사하는 팬톰)을 제작하였으며, 전산화단층촬영으로 3차원 영상을 획득하였다. 전산화치료계획장치(ECLIPSE, Varian, USA), 6 MV X선(Clinac 6EX, Varian, USA)을 이용하여 세기조절 방사선치료계획을 수립한 후, 전립선암 환자형 골반 팬톰을 이용하여 직장벽, 방광벽, 정낭 부위에 TLD를 삽입하고, 전산화치료계획 선량과 비교하였다. 결 과: 전산화치료계획에 의한 선량은 직장벽 100%, 방광벽 52%, 우측 정낭 86%, 좌측 정낭 87%, 표면 18%였으나, TLD로 측정 한 선량은 직장벽 89%, 방광벽 54%, 우측 정낭 85%, 좌측 정낭 84%, 표면 17%로 측정되었다. 직장벽은 11%, 방광벽은 2%, 우측 정낭은 1%, 좌측 정낭 3%, 표면 1%의 선량차이를 확인하였다. 결 론: 본원에서 개발한 전립선암 환자형 골반 팬톰으로 전산화치료계획에서 구현하는 불균질부 선량계산의 오차를 확인할 수 있었으며, 다양한 선량 측정 장치(TLD, film)를 이용하여 쉽고 간편하게 선량 검증을 할 수 있을 것으로 사료된다.

  • PDF

The Use of Lens Shielding Device(L.S.D.) for a Conjunctival Lymphoma

  • 조현상;주상규;송기원;박영환
    • 대한방사선치료학회지
    • /
    • 제9권1호
    • /
    • pp.40-45
    • /
    • 1997
  • When therapeutic irradiation is indicated for the orbital tumors, the greatest concern is the risk of radiation-induced cataract. Conjunctival lymphoma is one of the good examples. We would like to report the procedure of the lens shielding device(L.S.D) and the result of irradiated dose to the lens. L.S.D. consistes of two parts : load alloy to attenuate electron beam, and dental acryl which completely covers the lead alloy to avoid discomfort of cornea from contacting directly with cerrobend and side scattering by cerrobend. And for easy location and removal, side bars were made on each side. Radiation doses were meaured with TLD(TLD 3500 Hawshaw). Markus chamber in a polystyrene phantom. The phantom was irradiated with 9MeV electron beams from Clinac 2100C with $6{\times}6cm$ electron cone. The relative dose at 6mm depth where the lens is located was $4.2\%$ with TLD and $5.1\%$ with Markus chamber clinically when 2600 cGy are irradiated to the eyeball, the mapinary dose to the lens will be 109 cGy or 132 cGy, which will significently reduce the cataract.

  • PDF