Browse > Article
http://dx.doi.org/10.5392/JKCA.2014.14.11.864

Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter  

Kang, In-Seog (인천기독병원 영상의학과)
Ahn, Sung-Min (가천대학교 방사선학과)
Publication Information
Abstract
To propose a basis for the selection of personal dosimeters to measure radiation dose administration of radiation workers as a way to evaluate the usefulness dosimeter. For the dosimetry of the radiation workers 2012, during 1 year, 30 were radiation workers to measure personal dose. By personal exposure is measured cumulative dose, is investigated the performance of the TLD, PLD, OSLD. And comparing the measured value of each dosimeter dose and analyzed. Medical institutions, inspection work and quarterly confirmed the cumulative exposure dose of radiation workers. Using DAP and Ion-Chamber, to measure to compare TLD, PLD, OSLD dosimeter performance. A comparison of the directly through the X-ray dosimeter and The absolute value of the Ion-Chamber, OSLD more similar than in the TLD and PLD showed the dose values so the excellent ability to measure the results. Also in radiation generating area dose of radiation workers is higher than that in OSLD. Consequently, in terms of the individual exposure management OSLD is appropriated and beneficial than others.
Keywords
TLD; PLD; OSLD;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 B. S. Lim, "Radiation exposure dose on persons engaged in radiation -related industries in Korea," Journal of radiological science and technology, Vol.29, No.3, pp.185-195, 2006.   과학기술학회마을
2 H. R. Jung, C. H. Lim, and M. K. Lee, "A review of personal radiation dose per radiological technologists working at general hospitals," Journal of radiological science and technology, Vol.28, No.2, pp.137-144, 2005.   과학기술학회마을
3 식품의약품 안전평가원, 2011년도 의료기관 방사선관계종사자의 개인피폭선량 연보, 2012
4 이해룡, "방사선종사자의 개인 피폭선량 측정", 국립보건원보, Vol.29, No.2, pp.460-466, 1992.
5 권석근, 김용민, 김창규, 방사선관리학개론, 한국동위원소협회, 2012.
6 하호영, "진단방사선 영역에서 피폭선량감소를 위한 기술적 연구", 대한방사선기술학회지, Vol.15, No.1, pp.89-97, 1992.
7 International Commission on Radiation Protection. General Principles of Monitoring for Radiation Protection for Workers, ICRP Publication 35 Ann, ICRP, Vol.9, No.4, 1982.
8 정운관, "필름배지 선량계에 의한 개인피폭선량 측정에 관한 연구", 방사선방어학회지, Vol.19, No.1, pp.41-58, 1994.
9 정홍량, 임청환, 이만구, "전국 종합병원 방사선사의 개인피폭선량에 대한 고찰", 방사선기술과학학회지, Vol.28, No.2, pp.137-144, 2005.   과학기술학회마을
10 최재호, 강주군, 장서구, "DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정비교", 한국콘텐츠학회논문지, Vol.12, No.3, pp.244-250, 2012.
11 강보선, 김가중, 김승국, 방사선계측학, 청구문화사, 2010
12 채건식, 김영국, 손인호, "열형광선량계에 관한 연구", 경남대학교신소재연구소 논문집, Vol.5, pp.143-151, 1995.
13 C. Esquivel, M. S. Smith, and M. S. Sotirios Stathakis, In Vivo Dose Measurements for Total Body Irradiation using Optically Stimulated Luminescent Dosimeters, American Association of Physicists in Medicine, 2009.
14 C. Esquivel, M.S. Smith, and M.S. Sotirios Stathakis, "Total Skin Electron Therapy Skin Dose Validation Using Optically Stimulated Luminescent Dosimeters," American Association of Physicists in Medicine, 2009.
15 이왕희, 김성철, 안성민, "광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교", 한국콘텐츠학회논문지, Vol.12, No.12, pp.329-334, 2012.   과학기술학회마을   DOI   ScienceOn
16 진단용방사선안전관리규정, 2011. 식품의약품 안전평가원, 2011년도 의료기관 방사선관계종사자의 개인피폭선량 연보, 2012.