• Title/Summary/Keyword: TL Curve

Search Result 97, Processing Time 0.021 seconds

Application of PSL and TL Detection Method by Irradiation doses on the Foods Approved to Irradiation in Korea (조사 선량에 따른 품목별 PSL과 TL 시험법 적용 가능성 검증)

  • Cho, Joon-Il;Lee, Ji-Ae;Chung, Hyung-Wook;Lee, Soon-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • This research was conducted to know application of Photostimulated luminescence (PSL) and Thermoluminesce(TL) methods by irradiation dose for leaching tea, sauces and starch approved in Korea. Leaching tea, sauces and starch powder were treated with $^{60}Co$ gamma ray at dose 0~10 kGy for detection trial whether they are irradiated or not by measuring PSL and TL for whole samples. PSL values were less than threshold value 700 and were, negative for non-irradiated samples but more than 5,000 and were positive for irradiated ones. PSL results of leaching tea and sauces showed the correct identification for non-irradiated and irradiated samples, respectively except starch samples. To enhance the reliability of the TL result, the first glow curve (TL1) was compared with the second glove curve (TL2) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold for both the non-irradiated (< 0.1) and irradiated (> 0.1) samples. TL results of leaching tea, sauces, starch showed the correct identification for non-irradiated and irradiated samples, respectively. This study was performed to know application of PSL and TL methods for leaching tea, sauces and starch, and the methods were able to detect the irradiation products.

Application of PSL-TL Combined Detection Method on irradiated Composite Seasoning Products and Spices (방사선 조사 복합조미식품과 향신료의 확인을 위한 PSL-TL의 적용)

  • Chung, Hyung-Wook;Park, Sung-Kug;Han, Sang-Bae;Choi, Dong-Mi;Lee, Dong-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.206-211
    • /
    • 2008
  • Photostimulated luminescence(PSL)-Thermoluminescence(TL) combined analysis was applied to detect whether composite seasoning products and spices were irradiated or not. Samples were irradiated with $^{60}Co$ at $0{\sim}7$ kGy. A total of 12 different samples(6 of composite seasoning products and 6 of spices) was examined. Depending on the PSL results, TL analysis was performed. In case of both PSL positive(${\geq}5,000$ counts) and intermediate($700{\sim}5000$ counts), TL analysis had to be performed to confirm the result of PSL. Using TL, the shape of the glow curve(Glow 1) made it possible to identify the irradiated samples. In addition, The TL glow ratio(Glow 1/Glow 2) obtained by normalization was less than 0.1 for the non-irradiated samples and ${\geq}0.29$ for irradiated ones, respectively.

Defect center of $Li^{+}$ ion implanted $Al_2O_3$ ($Li^{+}$ 이온 주입된 $Al_2O_3$의 결함 특성)

  • Kim, Tae-Kyu
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The thermoluminescence(TL) glow curves and the optical absorption of $Al_2O_3$ irradiated with ${\gamma}$-ray, electron, and $Li^{+}$ ion followed by electron irradiation have been investigated to determine the relation of TL peak to its defect type. The TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows TL peaks at 380 K, 415 K, and 475 K. The UV photobleached TL glow curve of $Al_2O_3$ irradiated with ${\gamma}$-ray shows that the 380 K and 475 K TL peaks completely disappear while the 415 K TL peak still exists. The electron beam induced TL glow curve of $Al_2O_3$ after $Li^{+}$ ion implantation shows that the TL peak at 440 K is enhanced by a factor of 2 over the TL intensity of unimplanted $Al_2O_3$ while the TL peak at 380 K evidently disappears The implanted $Li^{+}$ ions are assumed to form singly charged interstitial cations and then recombine with electron trapped in F centers to produce F+ centers. The 380 K and 475 K TL peaks are proposed to be associated with F center, while the 415 K and 440 K TL peak are connected with F$^{+}$ center.

  • PDF

Analyzing a Physical Marker to Identify Irradiated Dried Garlic and Cabbage (건마늘과 건양배추의 방사선 조사여부 확인을 위한 물리적 마커 분석)

  • Kim, Dong-Gil;Ahn, Jae-Jun;Jin, Qiong-Wen;Lee, Ho-Cheon;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.136-140
    • /
    • 2009
  • The verification of irradiation treatments, using dried garlic and cabbage treated at 0-20 kGy, was investigated by analyzing the photostimulated luminescence (PSL), electron spin resonance (ESR) and thermoluminescence (TL) characteristics of the samples. The PSL results showed that the photon counts/60 sec of the non-irradiated dried garlic and cabbage were 287-337, corresponding to negative, while those of the irradiated samples were 7511-54063 photon counts/ 60 sec, corresponding to positive, making it possible to discriminate the non-irradiated from the irradiated samples. In ESR analysis, the dried garlic irradiated at 20 kGy exhibited cellulose radicals, whereas the irradiated dried cabbage showed crystalline sugar-induced multi-component signals, which were not found in the non-irradiated samples. The ESR signal intensity significantly increased as the irradiation dose increase ($R^2$= 0.9369 - 0.9926). The TL glow curves of the irradiated samples appeared at a temperature interval of 150-250, which were significantly different from those of non-irradiated samples, showing a significant increase in TL signal intensity with irradiation dose ($R^2$= 0.9670 - 0.9768). To enhance the reliability of the results, the first glow curve ($TL_1$) was compared with the second glow curve ($TL_2$) obtained after a re-irradiation step at 1 kGy. The TL ratio ($TL_1/TL_2$) was in good agreement with the reported TL threshold values for both the non-irradiated (<0.1) and irradiated (> 0.1) samples.

ANALYSIS OF THE LiF:Mg,Cu,Si TL AND THE LiF:Mg,Cu,P TL GLOW CURVES BY USING GENERAL APPROXIMATION PLUS MODEL

  • Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul;Oh, Mi-Ae;Chung, Ki-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.155-164
    • /
    • 2009
  • In this paper, we used computerized glow curve deconvolution (CGCD) software with several models for the simulation of a TL glow curve which was used for analysis. By using the general approximation plus model, parameters values of the glow curve were analyzed and compared with the other models parameters (general approximation, mixed order kinetics, general order kinetics). The LiF:Mg,Cu,Si and the LiF:Mg,Cu,P material were used for the glow curve analysis. And we based on figure of merits (FOM) which was the goodness of the fitting that was monitored through the value between analysis model and TLD materials. The ideal value of FOM is 0 which represents a perfect fit. The main glow peak makes the most effect of radiation dose assessment of TLD materials. The main peak of the LiF:Mg,Cu,Si materials has a intensity rate 80.76% of the whole TL glow intensity, and that of LiF:Mg,Cu,P materials has a intensity rate 68.07% of the whole TL glow intensity. The activation energy of LiF:Mg,Cu,Si was analyzed as 2.39 eV by result of the general approximation plus(GAP) model. In the case of mixed order kinetics (MOK), the activation energy was analyzed as 2.29 eV. The activation energy was analyzed as 2.38 eV by the general order kinetics (GOK) model. In the case of LiF:Mg,Cu,P TLD, the activation energy was analyzed as 2.39 eV by result of the GAP model. In the case of MOK, the activation energy was analyzed as 2.55 eV. The activation energy was analyzed as 2.51 eV by the GOK model. The R value means different ratio of retrapping-recombination. The R value of LiF:Mg,Cu,Si TLD main peak analyzed as $1.12\times10^{-6}$ and $\alpha$ value analyzed as $1.0\times10^{-3}$. The R of LiF:Mg,Cu,P TLD analyzed as $7.91\times10^{-4}$, the $\alpha$ value means different ratio of initial thermally trapped electron density-initial trapped electron density (include thermally disconnected trap electrons density). The $\alpha$ value was analyzed as $9.17\times10^{-1}$ which was the difference from LiF:Mg,Cu,Si TLD. The deep trap electron density of LiF:Mg,Cu,Si was higher than the deep trap electron density of LiF:Mg,Cu,P.

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

The Retrieval of Abnormal TL Glow Curves Using Modified Glow Curve Analysis Method

  • Lee, Sang-Yoon;Lee, Kun-Jai;Kim, Jang-Lyul;Chang, Si-Young
    • Nuclear Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.385-392
    • /
    • 1997
  • The shape of TL glow curve is a useful indicator for assurance of correct reading of the personal dosimeter. Since the reading procedure of TLD is irreversible, however, an analytic remedy should be considered to procure reliable dosimetric information for the readings with irregular glow con shape. In this study, kinetic trapping parameters of CaSO$_4$ : Dy Teflon personal dosimeter(Teledyne PB-6A) were analyzed by Halperin and Braner's model for general-order kinetics. From these kinetic tapping parameters, we also developed a simple procedure to retrieve the dosimetric information from abnormally distorted glow curves. The computerized glow curve deconvolution(CGCD) fitting of the reference glow curve with kinetic parameters from this study yields relative errors of about 5% from the expected integral. It was also found that the glow curve remedial procedure developed could retrieve the distorted TL glow curves within ewer ranges of 1575. With the glow curve retrieval techniques, doses incurred by gamma radiation can now be successfully re-constructed for the CaSO$_4$ : Dy Teflon dosimeter resulting abnormal glow curves.

  • PDF

Detection of Radiation Induced Markers in Oranges Imported from the United States of America (미국산 오렌지의 Radiation Induced Marker 검색)

  • 조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Radiation induced markers were investigated for the detection of irradiated oranges imported from America. In the DNA comet assay, the non-irradiated and irradiated samples showed the comets with long tails in both seed and flesh. Though this tendency was maintained for 6 weeks, identification of non-irradiated or irradiated samples was impossible. In the thermoluminescence (TL) measurement, the non-irradiated samples revealed a glow curve with low intensity at about 28$0^{\circ}C$, while the irradiated samples showed with higher intensity at around 18$0^{\circ}C$. There were no remarkable changes in detection properties for 6 weeks after irradiation. The TL ratio of area for TL$_1$ glow curve to TL$_2$ was below 0.1 for the non-irradiated samples and 0.5 or more for the irradiated ones during storage. In the electron spin resonance (RSR) measurement, irradiated oranges showed an unspecific central signal in all parts (seed, flesh and peel), so the detection for radiation treatment of oranges was impossible. Based on the results, DNA comet assay and ESR were not useful for the detection, but TL was appropriate to search radiation induced markers of oranges during storage period. The detectable period during storage is confirmed by sensory evaluation.

Detection Characteristics of Gamma-Irradiated Korean Medicinal Herbs by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석에 의한 감마선 조사 한약재의 검지 특성)

  • Yang, Hee-Sun;Park, Yong-Dae;Jin, Chang-Hyun;Choi, Dae-Seong;Chung, Hyung-Wook;Byun, Myung-Woo;Jeong, Il-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1529-1533
    • /
    • 2008
  • The detection characteristics of gamma-irradiated ($0{\sim}10.0\;kGy$) medicinal herbs (Platycodon grandiflorum, Acanthopanax chiisanensis) were investigated by photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of the PSL, a first screening method in comparison with the TL, showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples, while the non-irradiated samples yielded photon counts less than 700 counts/60 s (negative). The TL was also applied for the detection method of irradiated medicinal herbs and showed that the non-irradiated sample revealed a glow curve with a low intensity, while the irradiated samples showed a higher intensity. These results were normalized by re-irradiating the mineral grains with a irradiation dose of 1.0 kGy, and a second glow curve was recorded. The ratio of the intensity of the first glow curve ($TL_1$) to that after the normalization dose ($TL_2$) was determined and compared with the recommended threshold values. TL ratio ($TL_1/TL_2$) was below 0.007 for the non-irradiated sample and higher than 0.1 for all irradiated samples (above 1.0 kGy). ESR spectroscopy revealed specific signals (6.065 mT) derived from free radicals in cellulose containing irradiated medicinal herbs. The P. grandiflorum showed clearer signals than A. chiisanensis. From the results of our studies, the PSL, TL, and ESR determinations were found to be suitable for the detection of irradiated medicinal herbs such as P. grandiflorum and A. chiisanensis.

More Powerful Test for Normality Based on the Normalized Sample Lorenz Curve (NORMALIZED SAMPLE LORENZ CURVE를 이용한 검정력이 높은 정규성 검정)

  • 강석복;조영석
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.415-421
    • /
    • 2002
  • Because most common assumption is normality in statistical analysis, testing normality is very important. We propose a new plot and test statistic to test for normality based on the modified Lorenz curve that is proved to be a powerful tool to measure the income inequality within a population of income receivers. We also compare the proposed test statistics with the W test (Shapiro and Wilk (1965)), TL test (Kang and Cho (1999)) in terms of the power of test through by Monte Carlo method. The proposed test is more usually powerful than the other tests except some case.