• 제목/요약/키워드: TEST-1

검색결과 59,887건 처리시간 0.064초

일본내 연구동향(6편중 제 2편) (Some Aspects of Mechanical Test Methods for Advanced Composites)

  • Fukuda, Hiroshi;Wada, Atsushi
    • Composites Research
    • /
    • 제15권1호
    • /
    • pp.61-69
    • /
    • 2002
  • This paper review research activities of some mechanical test methods thor advanced composites which have been conducted in Fukuda laboratory. Tokyo University of Science. The subjects are (1) innovation and development of compression bending test. (2) mechanical-property evaluation of soft-core sandwich beam, and (3) loop test to measure the strength of monofilaments.

인삼 육성계통의 Fusarium sozani에 의한 근부병 저항성 비교 (Comparison of Resistance of Root Rot Caused by Fusarium solani in Ginseng Breeding Lines)

  • 천성룡;김홍진
    • Journal of Ginseng Research
    • /
    • 제14권1호
    • /
    • pp.50-56
    • /
    • 1990
  • Root-rot of ginseng caused by Fusarium solani is one of the most obstacles to ginseng cultivation. We evaluated some inoculating techniques of ginseng with Fusarium solani, for selection of disease resistant breeding lines. The most effective inoculating techniques evaluated were inserting toothpicks colonized by F. solani into the seedling roots in laboratory test and dusting seedlings with vermiculite after dipping in conidial sllspension and then replanting method in field test. The resistance to diseased by F. solani was lines of 82022 and 82066 in laboratory test. 82920-1 and 78093 in field test.

  • PDF

An Experiment of Traceability-Driven System Testing

  • Choi, Eun-Man;Seo, Kwang-Ik
    • Journal of Information Processing Systems
    • /
    • 제4권1호
    • /
    • pp.33-40
    • /
    • 2008
  • Traceability has been held as an important factor in testing activities as well as model-driven development. Vertical traceability affords us opportunities to improve manageability from models and test cases to a code in testing and debugging phase. This paper represents a vertical test method which connects a system test level and an integration test level in testing stage by using UML. An experiment how traceability works to effectively focus on error spots has been included by using concrete examples of tracing from models to the code.

새로운 체전굴 측정 방법의 개발 (Development of The New Instrument for Measuring of Trunk-Hip Forward Flexion)

  • 이건범
    • 한국운동역학회지
    • /
    • 제12권2호
    • /
    • pp.245-257
    • /
    • 2002
  • 이 연구의 목적은 간단하고 실용적이며, 타당성, 신뢰성, 객관성이 높은 체전굴 유연성 측정 도구를 개발하는데 있으며, D여자 대학교의 스포츠학 전공 여대생 44명이 자발적으로 연구의 피검자로 참여하였다. 새 측정 도구의 신뢰도와 객관도 검사는 재검법의 평균 측정값을 사용하여 이원 혼합효과 모델에 의한 급내 상관 계수를 산출하였다. 검사자별 1차와 2차의 급내 상관 계수는 L은 R = .994, Y는 R=.993, 1차와 2차 검사의 L과 Y검사자간 급내 상관 계수는 R = .985, R=.986으로 모두 상관도가 아주 높은 것으로 나타났다. 새로 개발한 체전굴 측정 도구의 타당도 검증을 위하여 Leighton-flexometer-tests의 원리를 이용한 Takei 의 flexometer를 준거 검사 도구로 사용하였으며, 1차 검사와 2차 검사에서의 새로운 체전굴 유연성 측정 도구와 준거 검사 도구 측정값의 Pearson 적률 상관계수는 각각 r = .962와 r = .960로 1, 2차 검사 모두 아주 높은 상관도를 나타냈다. 결론적으로 본 연구에서 새로 개발한 체전굴 검사는 타당도, 신뢰도, 객관도가 매우 높고 실용적인 것으로 평가될 수 있음이 밝혀졌다.

조경 녹화용 방수.방근층의 방근 성능평가 시험방법에 관한 연구 - 모의 바늘과 지하경을 이용한 방근 성능평가 시험방법 - (A Study on Test Method for Evaluating Root Resistance in Waterproofing and Root Resistance Membrane Used in Landscape Architecture - A Test Method for Evaluating Root Resistance that Use a Simulated Needle and a Rhizome -)

  • 이준호;표순주;신진학;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 산업계
    • /
    • pp.89-97
    • /
    • 2009
  • As landscaping building roofs and concrete structures increase gradually for low carbon green growth policy of government, But waterproofing membranes of those structures are effecting by root penetration of landscape plant. 80, we progressed study about test method for fast evaluating root resistance of waterproofing materials jointly with Tokyo Institute of Technology. The result of the study is as follows: (1) The penetrating load of the needle at the displacement speed of 1mm/min was measured for various membrane to basis and lap joints of membrane, the load force was $3{\sim}50$ N by material variously. (2) According to the test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane, there were no penetrated membrane until present, but need persistent observation. (3) Test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane can shorten from period of 2 years to 1 year for testing. Because rhizomes of bamboo grass can grow from May to September, test is possible in same period.

  • PDF

기본훈련기 방향타 조종장치 정적하중 시험에 관한 연구 (A Study on the Static Test of Rudder Control System for a Basic Trainer)

  • 전찬원;이수용;강규섭
    • 한국항공우주학회지
    • /
    • 제30권2호
    • /
    • pp.115-121
    • /
    • 2002
  • 본 논문은 KTX-1 기본훈련기 방향타 조종계통의 정적 하중 시험을 요약한 것이다. 방향타 콘트롤 시스템 정적 하중시험은 정하중 구조 시험용 KTX-1 #004호기에 장착 상태에서 실시하였으며 사용되는 모든 부품은 실제와 동일한 것으로 장착하고 정적하중 시험을 실시하였다. 시험하중 조건은 설계 제한하중(Design Limit Load)과 설계 극한하중(Design Ultimate Load)까지 시험을 수행하며, 전방석과 후방석 패달에 동시하중을 작용하는 경우 중복하중계수(Dual Factor)까지 고려하였다. 이 시험의 요구하중은 MIL-A-8855(USAF)의 요구조건에 따라 수행하였으며, 방향타 콘트롤 시스템 시험 결과는 미 군사규격 요구조건을 만족하였다.

물리치료와 작업치료가 근위축성측삭경화증 환자의 신체적 기능과 삶의 질에 미치는 영향: 사례연구 (The Effect of Physic Function and Quality of Life in Patient with Amyotrophic Lateral Sclerosis through Physical Therapy and Occupational Therapy: A Case Study)

  • 이태식;이환희
    • The Journal of Korean Physical Therapy
    • /
    • 제19권5호
    • /
    • pp.77-85
    • /
    • 2007
  • Purpose: This study was to investigated the effect of physical function and quality of life through physical therapy and occupational therapy by Bobath approach to patient with ALS. Methods: The data of 1 patient with ALS, who visited D hospital in Busan, was collected from June 5, 2006 to August 19, 2007. To determine the physical function and quality of life, Berg Balance Scale (BBS), Gait, Skate. Purdue Pegboard, WHOQOL-BREF, COPM were used. Results: BBS score was increased 0 to 33 in the pre and post test. Gait distance was increased 0m to 500m in pre and post test. Skate score was increased 13 to 22 in the pre and post test, Purdue Pegboard score was increased 0 to 3 in the pre and post test, WHOQOL-BREF was increased 1.92 to 2.46 in the pre and post test. Average COPM score of performance and satisfaction grade of pre test score was 1 then Post test score of performance score increased to 5.7 and satisfaction increased to 4. Conclusion: Physical therapy and Occupational therapy increase physical function and quality of life in ALS patients. Physical therapy and occupational therapy should study more about patients with ALS.

  • PDF

IEEE 1149.1 표준에 근거한 다중 클럭을 이용한 단일 캡쳐 스캔 설계에 적용되는 경계 주사 테스트 기법에 관한 연구 (Test Methodology for Multiple Clocks Single Capture Scan Design based on JTAG IEEE1149.1 Standard)

  • 김인수;민형복
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.980-986
    • /
    • 2007
  • Boundary scan test structure(JTAG IEEE 1149.1 standard) that supports an internal scan chain is generally being used to test CUT(circuit under test). Since the internal scan chain can only have a single scan-in port and a single scan-out port; however, existing boundary test methods can not be used when multiple scan chains are present in CUT. Those chains must be stitched to form a single scan chain as shown in this paper. We propose an efficient boundary scan test structure that adds a circuit called Clock Group Register(CGR) for multiple clocks testing within the design of multiple scan chains. The proposed CGR has the function of grouping clocks. By adding CGR to a previously existing boundary scan design, the design is modified. This revised scan design overcomes the limitation of supporting a single scan-in port and out port, and it bolsters multiple scan-in ports and out ports. Through our experiments, the effectiveness of CGR is proved. With this, it is possible to test more complicated designs that have high density with a little effort. Furthermore, it will also benefit in designing those complicated circuits.

스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 - (Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness -)

  • 김재옥;김철환;박종열
    • 펄프종이기술
    • /
    • 제36권1호
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

대한침구학회지 논문의 통계적 오류에 관한 연구 (An Assessment of Statistical Validity of Articles Published in the Journal of Korean Acupuncture & Moxibusition Society - from 1984 to 2002 -)

  • 이승덕
    • Journal of Acupuncture Research
    • /
    • 제21권1호
    • /
    • pp.176-188
    • /
    • 2004
  • This study was carried out to investigate statistical validity of medical articles that used various statistical techniques such as t-test, analysis of variance, correlation analysis, regression analysis and chi-square test. For study 429 original articles using those statistical methods were selected from Journal of Korean Acupuncture & Moxibusition Society published from 1984 to 2002. 429 original articles were reviewed to analyzed the statistical procedures. Results are summarized as follows : 1. In this study 93 articles(21.68%) of 429 ones didn't report statement of statistical method in detail. 2. 53 articles(12.53%) didn't report p-value in correctly, and 245 articles(57.11 %) used mean${\pm}$standard error (Mean${\pm}$SEM.) and 109 articles used mean${\pm}$standard deviation(Mean${\pm}$SD.). All of 23 articles using nonparametric statistical techniques made an error to central tendency or dispersion. 3. 175 articles(59.93%) and 14 articles(4.79%) of 292 ones made an error to description of equal variances and normal distribution. 4. 99 articles(50%) of 185 ones misused t-test and 4 articles of 5 ones misused chi-square test. 5. 28 articles(73.68%) of 38 ones using discrete variable misused parametric technique such as t-test or ANOVA. 2 articles and 1 article of 125 ones choosing paired samples misused independent t-test and Mann-Whitney U test. 6. 20 articles using analysis of variance didn't use multiple comparison.

  • PDF