• Title/Summary/Keyword: TEST CELL

Search Result 4,624, Processing Time 0.035 seconds

Optimization Analysis for Homogeneous Field Structure of GTEM-CELL (GTEM-CELL의 균일한 필드구조를 갖기위한 최적화 분석)

  • Kim, Jong-Seong;Seo, Kang;Jeong, Seong-IL;Lee, Han-Young;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.218-222
    • /
    • 2003
  • Even if using the standard field test which radiation of electric wave and measurement test equipment there are difficult thing that building test equipment. so, we can use the substitution test field. In this paper, for optimization analysis for homogeneous field structure of GTEM-CELL (Giga hertz Transverse Electro Magnetic Cell) that calculate electromagnetic field characteristic for variable of each structure and characteristic impedance inner conductor.

  • PDF

Polymer Electrolyte Fuel Cell Simulation Using Simulink (Simulink를 이용한 고분자 전해질 연료전지 시스템 시뮬레이션)

  • Hwang, Nam-Sun;Lee, Ho-Jun;Ju, Byung-Su
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.109-112
    • /
    • 2007
  • In this paper, a mathematical modeling was developed to simulate 1kW class air cooled Polymer Electrolyte Membrane Fuel Cell(PEMFC) system. The proposed modeling was conducted under SIMULINK based environment. The model ing was developed based on the thermodynamic and chemical equilibrium. The objective is to design and implement the entire fuel cell system model ing including the system controller modeling. The fuel cell process and the control system modeling should have to be connected with each other simultaneously, therefore the two types of modeling influences each other when the system simulator run. The fuel cell modeling libraries are simulated using the SIMULINK under the thermodynamic and chemical equilibrium base. The PID controller application was designed and developed to test the process modeling and verify it. This the prototype development of the fuel cell system to design and test more complicate fuel cell systems, like the residential power generation system. The simulation results was compared to the real PEMFC system performance. We have achieved the reasonable accordance with the Lab test and the simulation results.

  • PDF

Delay Test for Boundary-Scan based Architectures (경계면 스캔 기저 구조를 위한 지연시험)

  • 강병욱;안광선
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF

The Study on Acute and Subacute Toxicity and Sarcoma-180 Anti-cancer Effects of Armeniacae amarum semen Herbal-Acupuncture(Haeng-In) (행인약침(杏仁藥鍼)의 급성(急性) 아급성(亞急性) 독성실험(毒性實驗) 및 Sarcoma-180 항암효과(抗癌效果)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Kim, Ok;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.5 no.1 s.8
    • /
    • pp.61-79
    • /
    • 2002
  • Objective: The purpose of this study was to investigate acute and subacute toxicity and sarcoma-180 anti-cancer effects of Herbal acupuncture with Anneniacae amarum semen (Haeng-in) in mice and rats. Method: Balble mice were injected intraperitoneany with Haeng-In extract for $LD_{50}$ and acute toxicity test. Sprague-Dawley rats were injected intraperitoneally with Haeng-In extract for subacute toxicity test. TheAnneniacae amarum semen Herbal-Acupuncture was injected on Chung-wan (CV12) of mice with Sarcoma-180 cancer cell line. Results: 1. $LD_{50}$ was uncountable as none of the subjects expired from the treatment groups during the test. 2. The clinical signs and the body weight of mice treated with 0.1cc and 0.2cc Haeng-In extract were not affected during the acute toxicity test. 3. In acute toxicity test of serum biochemical values of mice, total protein and albumin were decreased in treatment group Ⅰ. Glucose was increased, and total cholesterol was decreased in treatment groups. GPT was increased in treatment group Ⅰ. 4. In subacute toxicity test, toxic symptoms were not detected in the treatment groups. 5. In subacute toxicity test, the body weight was increased in treatment groups on 14th and 21st day. 6. In subacute toxicity test. liver weight was increased in treatment group Ⅱ, and spleen weight was increased in treatment group Ⅱ. Lung weight was increased in an the treatment groups.(p<0.05) 7. In subacute toxicity test, severe tissue injury was found in lung and liver, especially treatment group Ⅰshowed more significant lung damage compared to treatment group l. 8. In subacute toxicity test, WBC. MCH and MCHC were increased in an the treatment groups, RBC, HGB and HCT were decreased in treatment group H(p<0.05). 9. In subacute toxicity test of serum biochemical values of rats, triglyceride was decreased in all the treatment groups. ALP was decreased in treatment group Ⅰ. and creatinine was decreased in treatment group Ⅱ. BUN/CR was increased in treatment group Ⅱ(p<0.05). 10. Median survival time of Sarcoma-180 cancer cell treated with Haeng-In was increased in all the treatment groups by twenty percent, compared to the control group(p<0.05). 11. Natural killer cell activity about the Sarcoma-180 cell was decreased at the ratio of 100:1 but was increased at the ratio of 10:1. In treatment group Ⅱ, increase was found at the ratio of 100:1 and 50:1 (p<0.05). 12. Interleukin-2 productivity of the Sarcoma-180 cell was decreased in treatment group I, but was increased in treatment group Ⅱ(p<0.05). Conclusion: According to the results, we can conclude Herbal-acupuncture with Anneniacae amarum semen caused toxicity, and had effects in Sarcoma-180 cancer cell.

Effects of the Oocyte and Developmental Stages of the Rat Embryos after the Vitrified Freezing on the Survival Rate(FDA-test) (Rat 난포란과 수정란의 발육단계별 유리화 동결 융해후 생존성(FDA-test)에 미치는 영향)

  • 고혁진;김중계
    • Journal of Embryo Transfer
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 1996
  • This experiment was carried out to investigate the ovarian responses of the ovulation point, ovarian weight and size, the number of ovarian follicles and collected embryos, and to study the effects of the developmental stages (oocytes, 2-4 cell. 8-16 cell and morulae), additional levels of Ficoll (0, 15, 30%) on the survival rate (FDA-test) of rat embryos frozen in vitrification solution (20% glycerol + 10% ethylene glycol + 10% sucrose). Sunanarized results was as follows; 1. The mean ovulation point per head was 7, and the weight of ovaries was 0.03g. The size of ovary was 5.9 mm(L) and 4.6 mm(W), and the number of ovarian follicles over and below 2 mm was 4.7 and 8.7, respectively. The number of the collected embryos per head was 5.5 (79%). 2. 2. The FDA score of embryos frozen in 20 G 10 E 10 S without Ficoll was 2.8 (oocyte), 2.6 (2-4 cell), 3.9 (8-16 cell) and 3.6 (morula), respectively. However, there were no significant differences among treatments. 3. The FDA score of embryos frozen in 20 G 10 E 10 S with 15% Ficoll was 3.4 (oocyte), 4.0 (2-4 cell), 4.7 (8-16 cell) and 4.8 (morulae), respectively (P>0.05). 4. The FDA score of embryos frozen in 20 G 10 E 10 S with 30 % Ficoll was 3.7 (oocyte), 3.2 (2-4 cell), 4.4 (8-16 cell) and 4.4 (morulae), respectively (P>0.05). 5. As shown in the above results, the higher survival rate was obtained in the treatment of 15% Ficoll than that of 30%. And the survival rate (FDA-test)of the oocytes and 2-4 cell stages of the rat embryos was lower than that of 8~16 cell and morulae stages. It was considered that 8-16 cell and morulae could be available for the successful freezing by vitrification of rat embryos with 15% Ficoll except for oocytes.

  • PDF

Evaluation of Commercial Anion Exchange Membrane for the application to Water Electrolysis (수전해 시스템에 적용하기 위한 상용 음이온교환막의 특성평가)

  • Jun Ho, Park;Kwang Seop, Im;Sang Yong, Nam
    • Membrane Journal
    • /
    • v.32 no.6
    • /
    • pp.496-513
    • /
    • 2022
  • In this study, we sought to verify the applicability of anion exchange membrane water electrolysis system using FAA-3-50, Neosepta-ASE, Sustainion grade T, and Fujifilm type 10, which are commercial anion exchange membranes. The morphology of the commercial membranes and the elements on the surface were analyzed using SEM/EDX to confirm the distribution of functional groups included in the commercial membranes. In addition, mechanical strength and decomposition temperature were measured using UTM and TGA to check whether the driving conditions of the water electrolyte were satisfied. The ion exchange capacity and ion conductivity were measured to understand the performance of anion exchange membranes, and the alkaline resistance of each commercial membrane was checked and durability test was performed because they were driven in an alkaline environment. Finally, a membrane-electrode assembly was manufactured and a water electrolysis single cell test was performed to confirm cell performance at 60℃, 70℃, and 80℃. The long-term cell test was measured 20 cycles at other temperatures to compare water electrolysis performance.

A Study on The Characteristics of Solar Cell by Thermal Shock test (열충격 시험을 통한 태양전지 특성에 관한 연구)

  • Kang, Min-Soo;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.249-253
    • /
    • 2012
  • In this study, The report analysed the characteristics of power drop in solar cell through thermal shock test. The solar cells were tested 500 cycles in $-40^{\circ}C$ lowest temperature and $120^{\circ}C$ highest temperature by thermal shock test on ironbound conditions, that excerpted standard of PV Module(KS C IEC-61215). The result of the efficiency analysis through measure of I-V, efficiency of Cell decreased from 13.9% to 11.0% and decreasing rate was 20.9% after test. The result of the surface analysis through EL, solar cell has damage of gridfinger and ribbon joint. Cell cracks were founded in damage of cells through cross section of solar cells. Also, Fill factors were decreased from 72.3% to 62.0% after thermal shock test and decreasing rate is 11.8%. therefore, Yearly power drop is aggravated with facts that cell crack, damage of surface and power loss of cell by change of I-V characteristic curve with decreasing of parallel resistance.

Mitigation of Potential-Induced Degradation (PID) for PERC Solar Cells Using SiO2 Structure of ARC Layer (반사방지막(ARC)의 SiO2 구조에 따른 PERC 태양전지 PID 열화 완화 상관관계 연구)

  • Oh, Kyoung Suk;Park, Ji Won;Chan, Sung Il
    • Current Photovoltaic Research
    • /
    • v.8 no.4
    • /
    • pp.114-119
    • /
    • 2020
  • In this study, Mitigation of Potential-induced degradation (PID) for PERC solar cells using SiO2 Structure of ARC layer. The conventional PID test was conducted with a cell-level test based on the IEC-62804 test standard, but a copper PID test device was manufactured to increase the PID detection rate. The accelerated aging test was conducted by maintaining 96 hours with a potential difference of 1000 V at a temperature of 60℃. As a result, the PERC solar cell of SiO2-Free ARC structure decreased 22.11% compared to the initial efficiency, and the PERC solar cell of the Upper-SiO2 ARC structure decreased 30.78% of the initial efficiency and the PID reliability was not good. However, the PERC solar cell with the lower-SiO2 ARC structure reduced only 2.44%, effectively mitigating the degradation of PID. Na+ ions in the cover glass generate PID on the surface of the PERC solar cell. In order to prevent PID, the structure of SiNx and SiO2 thin films of the ARC layer is important. SiO2 thin film must be deposited on bottom of ARC layer and the surface of the PERC solar cell N-type emitter to prevent surface recombination and stacking fault defects of the PERC solar cell and mitigated PID degradation.

Change of I-V Properties of Flexible CZTS Solar Cell Through Mechanical Bending Test (굽힘 시험에 의한 플렉시블 CZTS 태양전지의 I-V 특성 변화에 관한 연구)

  • Kim, Sungjun;Kim, Jeha
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.197-202
    • /
    • 2022
  • The CZTS solar cell is a thin film solar cell using an absorption layer composed of Cu, Zn, Sn, Se, and S, and is cheaper than a CIGS solar cell using In and Ga and more eco-friendly than a perovskite and CdTe solar cell using Pb and Cd. In this study, we conducted a bending test for flexible CZTS solar cells. Experiments were conducted in the direction of inner benidng with compressive stress and outer bending with tensile stress, and during the number of bending 1,000 times with a radius of curvature of 50 mmR, the efficiency of the solar cell decreased by up to 12.7%, and the biggest cause of efficiency reduction in both directions was a large decrease in parallel resistance.

An Efficient Built-in Self-Test Algorithm for Neighborhood Pattern- and Bit-Line-Sensitive Faults in High-Density Memories

  • Kang, Dong-Chual;Park, Sung-Min;Cho, Sang-Bock
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.520-534
    • /
    • 2004
  • As the density of memories increases, unwanted interference between cells and the coupling noise between bit-lines become significant, requiring parallel testing. Testing high-density memories for a high degree of fault coverage requires either a relatively large number of test vectors or a significant amount of additional test circuitry. This paper proposes a new tiling method and an efficient built-in self-test (BIST) algorithm for neighborhood pattern-sensitive faults (NPSFs) and new neighborhood bit-line sensitive faults (NBLSFs). Instead of the conventional five-cell and nine-cell physical neighborhood layouts to test memory cells, a four-cell layout is utilized. This four-cell layout needs smaller test vectors, provides easier hardware implementation, and is more appropriate for both NPSFs and NBLSFs detection. A CMOS column decoder and the parallel comparator proposed by P. Mazumder are modified to implement the test procedure. Consequently, these reduce the number of transistors used for a BIST circuit. Also, we present algorithm properties such as the capability to detect stuck-at faults, transition faults, conventional pattern-sensitive faults, and neighborhood bit-line sensitive faults.

  • PDF