• Title/Summary/Keyword: TEM-1

Search Result 1,832, Processing Time 0.033 seconds

TEM sample preparation of microsized LiMn2O4 powder using an ion slicer

  • Jung Sik Park;Yoon‑Jung Kang;Sun Eui Choi;Yong Nam Jo
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.19.1-19.7
    • /
    • 2021
  • The main purpose of this paper is the preparation of transmission electron microscopy (TEM) samples from the microsized powders of lithium-ion secondary batteries. To avoid artefacts during TEM sample preparation, the use of ion slicer milling for thinning and maintaining the intrinsic structure is described. Argon-ion milling techniques have been widely examined to make optimal specimens, thereby making TEM analysis more reliable. In the past few years, the correction of spherical aberration (Cs) in scanning transmission electron microscopy (STEM) has been developing rapidly, which results in direct observation at an atomic level resolution not only at a high acceleration voltage but also at a deaccelerated voltage. In particular, low-kV application has markedly increased, which requires a sufficiently transparent specimen without structural distortion during the sample preparation process. In this study, sample preparation for high-resolution STEM observation is accomplished, and investigations on the crystal integrity are carried out by Cs-corrected STEM.

Detection of CTX-M and TEM type extended-spectrum β-lactamases in Escherichia coli isolated from livestocks in Korea (국내 가축 유래 대장균에서 CTX-M 및 TEM형 extended-spectrum β-lactamases의 검출)

  • Cho, Jae-Keun;Sung, Myung-Suk;Kim, Jin-Hyun;Kim, Ki-Seuk
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • This study was conducted to investigate the prevalence and genotypes of extended-spectrum ${\beta}$-lactamase (ESBL) in 377 Escherichia coli isolated from healthy and sick animals. Two isolates (0.5%), each of which were isolated from diseased swine and chicken, respectively, were confirmed as ESBL producing isolates by double disk synergy test, and showed a multidrug resistant phenotype. Minimum inhibitory concentration of cefotaxime for the two ESBL producing isolates were 3~4 times higher than those of ceftazidime, respectively. By PCR and sequencing, one isolate from swine have both $bla_{CTX-15}$ and $bla_{TEM-1}$, and one isolate from chicken have $bla_{CTX-15}$ and $bla_{TEM-116}$. Also, these genes were transferred to E. coli J53 by conjugation. These two isolates showed unrelated pulsed-field gel electrophoresis. To our knowledge, this is the first time that $bla_{TEM-116}$ gene was identified in E. coli isolated from animals in Korea. These results suggest more prudent use of third- generation cephalosporins, and surveillance and monitoring for ESBL producing E. coli in both animals and their environments should be necessary.

Theory of High Resolution TEM Image Formation: Coherence (2) (TEM 관련 이론해설(7): 투과전자현미경의 고분해능 영상이론: 결맞음 (2))

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • In this review, the important ideas of coherence theory are introduced. The transfer function and damping envelopes of the microscope due to temporal and spatial coherence are described. The passbands and the condition of Scherzer focus are discussed in associated with the resolution of transmission electron microscope. The characterization of coherence is also described.

Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure (휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출)

  • Youn Ji-Hun;Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.810-814
    • /
    • 2005
  • Input power for TEM cell apparatus due to SAR(Specific Absorption Rate) for culture blood cell is determined by the transmission and reflection measurement of blood into the TEM cell. Blood cell with skin cell are reference culture cells for the study of EM wave effect. Exposure RF power from exposure apparatus to culture cell should not only exact for SAR value, but also should be based on the theoretical theory. In this paper, insertion loss of 50 g blood was measured to know exposure power per gram for culture blood cell, and input power of TEM cell due to SAR 0.8, 1.6, 3, 4 mW/g using the measured data are delivered. This study is for applying to EM wave exposure apparatus to culture cell.

An Investigation of In Situ TEM Heating Experiments of Powder Samples (분말 시료의 투과전자현미경 직접 가열 실험법 연구)

  • Kim, Youn-Joong;Jeung, Jong-Man;Lee, Young-Boo;Lee, Su-Jeong;Song, Ji-Ho
    • Applied Microscopy
    • /
    • v.31 no.4
    • /
    • pp.315-323
    • /
    • 2001
  • In situ TEM heating experiments utilizing kaolinite powder samples result in the following facts. (1) The water recirculation system adopted in the Gatan's heating holder is required to prevent specimen drift above $500^{\circ}C$. (2) Since the degree of phase changes depends on the thickness of powders below $600^{\circ}C$, examinations of both thin and thick specimens are required. (3) Sample preparation using Mo-grids is required for TEM heating experiments above $900^{\circ}C$. At these temperature ranges the effect of heating rate and holding time on the phase transition process increases drastically, so that a programmed temperature control is required. (4) TEM heating experiments of the embedded powders by epoxy for the cross-sectional view was limited due to the severe epoxy movement during heating above $300^{\circ}C$. Better methods of sample preparation are required to overcome this problem.

  • PDF

Measurement of Size Distributions of Submicron Electrosprays Using a Freezing Method and an Image Processing Technique (냉각법 및 영상 처리기법을 이용한 서브마이크론 정전분무 액적의 크기분포 측정)

  • Ku, Bon-Ki;Kim, Sang-Soo;Kim, Yu-Dong
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.100-106
    • /
    • 2001
  • The size distributions of electrospray droplets from the Taylor cone in cone-jet mode are directly measured by using a freezing method and a transmission electron microscope (TEM) image processing technique. These results are compared with the data obtained by an aerodynamic size spectrometer (TSI Aerosizer DSP). The use of glycerol seeded with NaI and a freezing method make it possible to sample droplets with their original sizes preserved. Since pictures of droplets are taken with TEM with very low vapor pressure of the solution, evaporation is suppressed by freezing. For liquid flow rates below 1 nl/sec, the measured droplet diameters by the TEM image processing technique and the aerosizer are in the range of 0.25 to $0.32{\mu}m$ and 0.30 to $0.40{\mu}m$, respectively. Comparing the TEM data with the aerosizer measurements, it has been revealed that the TEM image processing technique can afford more accurate values of droplet size distributions in the submicron range of 0.1 to $0.4{\mu}m$.

  • PDF

The Comparison of Field Uniformity and SAR between TEM, Loop and Combined Elemented 16 Channel Transmit Arrays (TEM 형과 Loop 형의 전송소자를 이용한 16채널 3T Body 전송코일의 자장 균일도와 안전도 비교)

  • Ryu, Yeunchul;Kim, Young Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.404-408
    • /
    • 2014
  • In this research we evaluate the excitation homogeneity and SAR of three different Tx arrays after B1+ Shimming in the human body at 3T. Through the simulations, we compared the field properties that are standard deviation and mean value of transverse magnetization for 1) strip line TEM array, 2) rectangular loop array, 3) combined array of strip line element and rectangular loop and shown the utilities of B1+ shimming in human body model. After B1+ shimming, it is evaluated four different types of SAR for body mesh through whole body simulation; those are average, maximum 1-cell, maximum 1-gram, and maximum 10-gram SAR. It appears that in this particular comparison an array based on strip line elements can produce better homogeneity and lower SAR than an array of rectangular loops or an array of combined elements (strip line and loop). While many factors are considered in designing coils for production, it is hoped that methods and results like these will be used in the future to guide decisions and maximize benefit.

Defects analysis of RE : YAG (RE = Nd3+, Er3+) single crystal synthesized by Czochralski method (Czochralski법으로 성장된 RE : YAG(RE = Nd3+, Er3+) 단결정의 결함분석)

  • Park, Cheong Ho;Joo, Young Jun;Kim, Hye Young;Shim, Jang Bo;Kim, Cheol Jin
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • RE : YAG ($RE=Nd^{3+}$, $Er^{3+}$) single crystals are laser diodes and generally grown by Czochralski method with controlling the various growth parameter. Since the defects occurred by temperature gradient or the rotation speed of solid-liquid growth interface act as the decline of crystal optical property during the growth procedure, crystalline quality improvement via defects analysis is necessary. The etch pit density (EPD) analysis was used to confirm the surface defect of grown RE : YAG single crystal and to select the area of transmission electron microscopy (TEM) analysis. Defects in the specimen produced by tripod polishing method such as buckling, rod shaped, bend contours by internal stress, segregation and others were observed by using 200 kV TEM and 300 kV FE-TEM.

TEM analysis of IBAD/RABiTS substrates prepared by Tripod polishing (Tripod polishing을 이용한 IBAD/RABiTS 기판의 TEM 분석)

  • Choi, Soon-Mee;Chung, Jun-Ki;Yoo, Sang-Im;Park, Chan;Oh, Sang-Soo;Kim, Cheol-Jin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Sample preparation plays a critical role in microstructure analysis using TEM. Although TEM specimen has been usually prepared by jet-polishing or Ar-ion beam milling technique. these methods could not be applied to YBCO CC which is composed of IBAD or RABiTS substrates, several buffet layers, and YBCO superconducting layer because of big difference in mechanical strengths between the metallic phase and oxide phases. To obtain useful cross-sectional information such as interface between the phases or second phases in YBCO CC, it is prerequisite to secure the large area of thin section in the cross-sectional direction. The superconducting layer or the buffer layers are relatively weak and fragile compared to the metallic substrate such as Ni-5wt%W RABiTS of Hastelloy-based IBAD, and preferential removal of weak ceramic phases during polishing steps makes specimen preparation almost impossible. Tripod polisher and small jig were home-made and employed to sample preparation. The polishing angle was maintained <$1^{\circ}$ throughout the polishing steps using 2 micrometers attached to the tripod plate. TEM specimens with large and thin area could be secured and used for RABiTS/IBAD substrate analyses. In some cases, additional Ar-beam ion milling with low beam current and impinging angle was used for less than 30 sec. to remove debris or polishing media attacked to the specimens.