Input power for TEM cell apparatus due to SAR(Specific Absorption Rate) for culture blood cell is determined by the transmission and reflection measurement of blood into the TEM cell. Blood cell with skin cell are reference culture cells for the study of EM wave effect. Exposure RF power from exposure apparatus to culture cell should not only exact for SAR value, but also should be based on the theoretical theory. In this paper, insertion loss of 50 g blood was measured to know exposure power per gram for culture blood cell, and input power of TEM cell due to SAR 0.8, 1.6, 3, 4 mW/g using the measured data are delivered. This study is for applying to EM wave exposure apparatus to culture cell.
Keywords
TEM Cell; SAR; Blood Cell; Culture Cell; Exposure Apparatus; EM Wave Effect;
Citations & Related Records
연도 인용수 순위
  • Reference
1 손태호, 신길상, '광학 및 전자현미경 관찰을 위한 마이크로파 생체조직 고정법', 제4회 전자기장의 생체영향에 관한 워크샵 논문집, 한국전자파학회, 1(1), pp. 133-144, 2000년 10월
2 C. A. Balanis, Antenna Theory, 2nd Ed., John Wiley & Sons Inc., 1997
3 EMFacts consultancy, 'Mobile phone health hazards', http://www.tassie.net.au/emfacts/mobiles/
4 lTN Online, 'Cancer scare for mobile phone users', lTN ONLINE, May 1999
5 한국전자파학회, '전자기장 노출에 대한 인체 보호 기준', 한국전자파학회지 전자파기술, 10(2),pp. 14-29, 1999년 6월