• Title/Summary/Keyword: TEG

Search Result 72, Processing Time 0.026 seconds

MEMS Design Flow Based on DFM Concept (DFM 개념을 적용한 MEMS design flow)

  • Han, Seung-Oh;Oh, Park-Kyoun;Silva, Mark da
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1466-1470
    • /
    • 2007
  • MEMS design flow based on DFM concept is presented and applied to gyroscope design as a test case. It is purposed to contribute to the yield improvement by considering the process-related parameters from the design phase. After defining the performance requirements, the sensitivity analysis should be done on the draft design(s) to find out the key parameters related with the device performance. By doing so, TEG can be designed for the selected process and/or material parameters. Through a set of test runs, the process capability is characterized and the material properties are extracted using the TEG. Then we can estimate the virtual yield of the current process for the designed device by running Monte Carlo analysis where the process and/or material property variations are considered. The estimated yield will make us redesign the device to be more robust or improve the current process to have the smaller variations.

Clinical Use of Thromboelastography as Monitor of Coagulopathy at the Pre and Post-Cardiopulmonary Bypass (개심술 환자의 체외순환 전후 혈전 탄성 묘사도의 임상적 이용)

  • 강경훈;김경훈
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1092-1096
    • /
    • 1997
  • Thromboelastography(TEG) enables a global assessment of hemostatic function to be made from a single blood sample, documenting the interaction of platelets with protein coagulation cascade from the time of the initial platelet-fibrin interaction, through platelet aggregation, clot strengthening and fibrin cross linking to eventual clot Iysis. Thirty-five patients(mean age 34$\pm$ 12) undergoing open heart surgery from April 1st, 1996 to August 31th, 1996 were investigated at preoperatively and immediate, one hour, and 24 hours after cessation of cardiopulmonary bypass using TEG. Comparisons were made between classic hematological indices and TEG data. There were statistically significant correlation between maximal amplitude(MA) and platelet count before CPB, activating clotting time(ACT) and TEG date(R time, K time and a angle) at 24-hour after CPB. The data on the predictive accuracy for postoperative bleeding at 24-hour after CPB, the TEG was significantly better than ACT(57%) or the coagulation profiles(43%) as a predictor of postoperative bleeding, with an accuracy rate of 100% (P=0.0043). In conclusion, TEG seems to be easy to use, clinically accurate, cost effective and provides data which can effectively manage a patient's hemostasis.

  • PDF

Development of 100W thermoelectric power generation module (100W급 열전발전 모듈 기술 개발)

  • Moon, Jihong;Hwang, Jungho;Lee, Uendo
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.321-322
    • /
    • 2015
  • Thermoelectric power generation has emerged as a promising alternative technology because it offers a potential application in the direct conversion of waste heat into electric energy. The performance of thermoelectric power generator depends on thermoelectric materials and thermoelectric power module designs. The main objective of this study is to design a 100W thermoelectric generation (TEG) module and to get optimal operating conditions of the module. The design and performance of the TEG module will be presented.

  • PDF

Study of Thermoelectric Generator with Various Thermal Conditions for Exhaust Gas from Internal Combustion Engine using Numerical Analysis (수치해석을 통한 엔진 배기가스의 조건 변화에 따른 열전소자 발전 특성에 관한 연구)

  • In, Byung Deok;Lee, Ki Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.243-248
    • /
    • 2013
  • Internal combustion engines typically expel 30%-40% of the energy supplied by fuel to the environment through their exhaust system. Therefore, further significant improvements in the thermal efficiency of IC engines are possible by recovering the waste heat from the engine exhaust gas. With this fact in mind, a numerical simulation was carried out to investigate the potential of using thermoelectric generation with an internal combustion engine for waste heat recovery. Physical parameters such as the exhaust temperature and mass flow rate were evaluated in the exhaust system, and the optimum location for inserting a thermoelectric generator (TEG) into the system was determined. The TEG will be located in the exhaust system and will use the energy flow between the warmer exhaust gas and the external environment. The optimum position of the temperature distribution and the TEG performance were predicted through numerical analysis. The experimental results obtained showed that the power output significantly increases with the temperature difference between the cold and hot sides of the TEG.

Ki-67 Immunostaining and its Correlation with Microvessel Density in Patients with Mutiple Myeloma

  • Himani, Bhankar;Meera, Sikka;Abhimanyu, Sharma;Usha, Rusia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2559-2564
    • /
    • 2016
  • Purpose: To compare Ki-67 index and microvessel density MVD) in multiple myeloma and non-myeloma patients and their correlation with each other and other prognostic markers. Materials and Methods: Forty patients were enrolled in this study between 2011-2013, 30 with multiple myelomas and 10 with non-malignant disease as controls. Proliferative activity was analyzed by Ki-67 and microvessel density (MVC) was assessed by CD34 and compared between two groups. In myeloma patients, correlation between Ki-67, MVD and other prognostic factors was assessed by Pearson correlation coefficient. Results: According to Durie Salmon staging criteria, 13 patients were of stage 1, 5 of stage II and 12 of stage III. Ki-67 expression showed a positive correlation with MVD (r=0.729, p<0.001) and was significantly higher (p<0.0001) in myeloma patients (range 35-80%, mean 60.1 %) as compared to controls (range 8-25%, mean 18.1%). $MVD/mm^2$ was also significantly (p<0.0001) higher in myeloma patients (range $62-237/mm^2$, mean $178.0/mm^2$) than controls (range $5.2-50/mm^2$, mean $18.3/mm^2$). Ki-67 and MVD, both increased progressively with increasing stage of myeloma. Ki-67 showed significant positive correlation with blood urea and lactate dehydrogenase and a significant negative correlation with serum albumin. MVD showed a significant positive correlation with blood urea, lactate dehydrogenase, serum creatinine, ${\beta}2$ microglobulin and skeletal lesions. Conclusions: Ki-67 and MVD are indicators of aggressiveness and poor prognosis having significant correlation with each other and other prognostic markers of multiple myeloma. Routine assessment of these markers may help to identify high risk patients, who may benefit from with more aggressive therapy.

Comparison of Ankle Joint Exercise and Thigh Exercise on the Isometric Strength of the Lower Limb and Balance Ability (다리 등척성 근력 및 균형 능력에 대한 발목관절 운동과 넓적다리 운동의 비교)

  • Lee, Woo-Jung;Lee, Sun-Ah;Kim, Ah-Ram;Yoo, Kyung-Tae;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.4
    • /
    • pp.153-162
    • /
    • 2019
  • PURPOSE: This study compared ankle joint exercise and thigh exercise on the isometric strength of the lower limb and balance ability. METHODS: Twenty-seven subjects were divided into ankle joint exercise (AEG, n=9), tight exercise (TEG, n=9), and control group (CON, n=9). AEG and TEG performed ankle joint and tight exercises three times a week for four weeks. The following were measured before and four weeks after each exercise: isometric strength at knee flexion and extension of the lower limb; isometric strength at ankle plantar flexion and dorsiflexion of the lower limb; static balance of trace length and C90 area; and the dynamic forward, backward, leftward, and rightward balance for each region. RESULTS: The results showed that the isometric strength of plantar flexion (p<.05) was increased significantly in AEG compared to those in TEG and CON. The dynamic leftward (p<.05) and rightward balance (p<.05) were increased significantly in both AEG and TEG compared to that in CON. On the other hand, the static balance of the trace length and C90 area, isometric strength of ankle dorsiflexion, knee flexion and extension of the lower limb, and dynamic forward and backward balance did not show significant differences between the groups. CONCLUSION: Ankle joint exercise improves the isometric strength of plantar flexion compared to tight exercise.

Effect of cooling patches on performance of photovoltaic-thermoelectric hybrid energy devices (쿨링패치 부착에 따른 태양광-열전 융합소자의 성능 연구)

  • Lee, Jaehwan;Cho, Kyoungah;Park, Yoonbeom;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.716-720
    • /
    • 2021
  • In this study, we examine the availability of a cooling patch to enhance the output power of a hybrid energy device (HED) comprising a photovoltaic cell (PVC) and a thermoelectric generator (TEG). The cooling patch attached on the back of the TEG drops the temperature of the PVC via the TEG and makes a large thermal gradient across the TEG under irradiances in a range of 200 to 1000 W/m2. The cooling patch is more effective for the output power of the HED as the irradiance increases, and it enhances the maximum output power of the HED to 42.1 mW at an irradiance of 1000 W/m2. The increment in the maximum output power reaches 27% owing to the attachment of the cooling patch that does not consume any power.

Recent Advances in Thermoelectric Power Generation Technology

  • Sharma, Ashutosh;Lee, Jun Hyeong;Kim, Kyung Heum;Jung, Jae Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • Thermoelectric power generation (TEG) technology with high figure of merit (ZT) has become the need of the modern world. TEG is a potent technology which can tackle most of the environmental issues such as global warming, change in climatic conditions over the globe, and for burning out of various resources of non-renewable energy like as petroleum deposits and gasolines. Although thermoelectric materials generally convert the heat energy from wastes to electricity according to the theories Seebeck and Peltier effects yet they have not been fully exploited to realize their potential. Researchers are focusing mainly on how to improve the current ZT value from 1 to 2 or even 3 by various approaches. However, a higher ZT value is found to be difficult due to complex thermoelectric properties of materials. Hence, there is a need for developing materials with high figure of merit. Recently, various nanotechnological approaches have been incorporated to improve the thermoelectric properties of materials. In this review paper, the authors have performed a thorough literature survey of various kinds of TEG technology.

Effect of Acute Phase Pain Control Using TENS on Pain Relief in Knee Osteoarthritis in a Rat Model

  • Chen, Chang-Da;Kim, Seung-Kyu;HwangBo, Gak
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.3
    • /
    • pp.15-20
    • /
    • 2021
  • PURPOSE: This study examined the influence of treadmill exercise with initial pain control using transcutaneous electrical nerve stimulation (TENS) on induced pain of knee osteoarthritis in rats. METHODS: Thirty adult male Sprague - Dawley rats were divided randomly into the TENS Group (TG, n = 10), Treadmill Exercise Group (TEG, n = 10), and Treadmill with TENS Group (TTG, n = 10). In the TG, TENS was performed for 20 min per day for two weeks with a TENS program at the knee joint. The TEG performed treadmill exercise 15 m/min for 20 min per day for two weeks. The TTG performed initial pain control by TENS program during the 1st ~ 3rd days, and treadmill exercise was performed using the TEG methods from the 4th day. The lumbar spine was extracted and processed using western blot analysis to evaluate pain (c-fos expression). RESULTS: The results showed that c-fos expression was decreased significantly in all groups after each intervention (p < .05). In particular, TTG produced the most significant decrease compared to the other groups. CONCLUSION: These results suggest that treadmill exercise with initial pain control using TENS is a suitable method for relieving pain in knee osteoarthritis.

A COMPARATIVE STUDY ON THE PROPERTIES OF FILLER-ADDED METHACRYLATE POLYMERS (필러를 배합한 메타크릴레이트 중합체의 물성에 관한 비교 연구)

  • Park Dong-Won;Choi Boo-Byong;Kwon Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.606-616
    • /
    • 2003
  • Purpose : The purpose of this study was to research the properties of some chemically cured methacrylate polymers such as MMA, HEMA, TEG-DMA, bis-GMA, GMA. Material and Method : 5 kinds of methacrylates were selected and added 2% tertiary amine and benzoyl peroxide to make a chemically curable polymer 25 micron crushed silicas which are treated with silane were selected as filler, they were added into methacrylate monomer until the consistency did not changed by the load of 500gram. All of the experimental resins were 5 kinds, and a serial test was done with 3 kinds of items including the filler contents, the tensile strength, and the bond strength. The number of specimen were 10 for each group. Filler contents were obtained by reducing the specimens to ashes at $600^{\circ}C$ for 1 hour. The specimens with the dimension of 6mm in diameter and 3mm thick were immersed in $37{\pm}1^{\circ}C$ distilled water for 24 hours before test, and tensile strength were measured with cross-head speed 1mm/min. Shear bond strength were mea sured on the specimens attached to bovine enamel etched with 37% phosphoric acid for 1 minute. Results : 1. Maximum filler incorporation was the highest as 75.5% on MMA, and the least as 53.4% on bis- GMA(p<0.0001). 2. The tensile stregth were MMA 141.3, GMA 154.3, TEG-DMA 157.4, bis-GMA 161.4 MPa, and HEMA showed the highest value, 226.9MPa(p = 0.0004). 3. The bond strength were GMA 10.1, TEG-DMA 11.7, HEMA 12.2, bis-GMA 13.3 MPa, and MMA showed the highest value, 15.3MPa, however statistical significances were not (p =0.3838), 4. TEG-DMA and HEMA were not different on the aspect of maximum filler contents and shear bond strength(p>0.05). Conclusion : HEMA can be used as an another diluent substituting TEG-DMA with the increased strength and with the constant bond strength and the constant filler contents.