• Title/Summary/Keyword: TE6

Search Result 882, Processing Time 0.027 seconds

Review on Needling or Moxibustion-prohibited Points in Chimgugapeulgyeong (침구갑을경(鍼灸甲乙經)의 침구금기혈(鍼灸禁忌穴)에 대한 소고(小考))

  • Kwon, Sun-Oh;Kim, Seung-Tae;Seo, Byung-Kwan;Park, Hi-Joon;Hahm, Dae-Hyun;Lee, Hye-Jung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.2
    • /
    • pp.57-70
    • /
    • 2010
  • Objectives : To investigate the meaning and the importance of needling or moxibustion- prohibited acupoints in Chimgugapeulgyeong(鍼灸甲乙經). Methods : We found needling or moxibustion-prohibited acupoints in Chimgugapeulgyeong, then investigated the causes of the prohibitions from the various literatures and the anatomical structures near the acupoints. Results : In Chimgugapeulgyeong, the needling and moxibustion-prohibited points were ST9, ST17, ST32, CV5, and CV15. The needling-prohibited points were LU2, LI13, ST12, BL56, KI2, KI7, TE8, TE19, GB3, CV8, GV24, and jwagak(左角). The moxibustion-prohibited points were LU3, LU8, ST1, ST7, ST8, ST30, ST33, BL5, BL6, BL15, BL30, TE18, TE21, TE23, GB22, GB33, GB42, GV6, GV15, GV16, GV17 and GV25. The major cause of developing prohibited needling or moxibustion was due to the possibility to damage vessels or organs near them; other causes were side effects brought by applying wrong stimulating method or inducing women sterilized. Conclusions : The prohibition of needling or moxibustion on the points found in Chimgugapeulgyeong had acceptable causes. Therefore the techniques of needling or moxibustion on the acupoint should be performed with care.

A Study on TE Scattering by a Conductive Strip Grating Over a Dielectric Layer (유전체층 위의 완전도체띠 격자구조에 의한 TE 산란에 관한 연구)

  • Yoon, Uei-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4158-4163
    • /
    • 2015
  • In this paper, the solutions of TE(transverse electric) scattering problems by a condutive strip grating over a dielectric layer are analyzed by using the FGMM(fourier galerkin moment method) and PMM(point matching method) known as a numerical method of electromagnetic fileld. The scattered electromagnetic fields are expanded in a series of floguet mode functions, the boundary conditions are applied to obtain the unknown field coefficients, and the conductive boundary condition is used for the relationship between the tangential electric field and the induced surface current density on the strip. The numerical results for the reflected and transmitted power of zeroth mode analyzed by according as the width and spacing of conductive strip, the relative permittivity and thickness of dielectric layer, and incident angles. Generally, according to the relative permittivity of dielectric layer increased, also the normalized reflected power of zeroth mode increased. To examine the accruacy of this paper, the numerical results of FGMM shown in good agreement compared to those of PMM.

Treatment of Textile Wastewater by Membrane-Bioreactor Process (막-생물반응조 공정을 이용한 염색폐수의 처리)

  • 강민수;김성수;황규대;강종림
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.60-61
    • /
    • 1996
  • 염색폐수를 처리하기 위하여, 일반적으로 물리.화학적 공정과 호기성 생물학적 공정을 조합한 방법들을 사용하고 있다. 하지만 호기성 생물학적 공정은 난분해성 물질의 제거능력이 낮고, 염색폐수의 주된 오염원인 염료분자가 호기성 미생물에 대한 에너지원으로 적합하지 않아 분해되기 어려우며, 물리.화학적 공정을 이용한 처리방법으로도 높은 처리효율을 얻을 수가 없다. 이러한 문제점을 극복하기 위하여 염색폐수 처리에 혐기-호기공정을 이용하며, 혐기성 공정에서 생물학적으로 분해되기 어려운 고분자 물질들을 가수분해하여 생물학적으로 분해가능한 저분자물질로 전환시키고, 호기성 공정에서 저분자 물질을 효과적으로 처라할 수 있기때문에 기존의 염색폐수 처리공정에 비하여 훨씬 높은 처리효율을 얻을 수 있다. 특히, 혐기성 미생물은 호기성 미생물에 비하여 난분해성 물질에 대한 분해력이 높고, 생물독성 물질에 대한 내성이 강하기 때문에 수중생물에 유해한 염료를 함유한 염색폐수의 색도제거에 효과적인 것으로 기대된다. 또한, 막분리 공정은 유기물 및 미생물이 막표면에 축적, 증식함으로써 막세공에 막힘현상을 초래하여 역세척 등의 물리적인 방법이나 화학약품을 이용한 화학적 세척 방법으로도 투과플럭스의 회복이 불가능한 상태를 유발함으로 막의 수명을 단축시키는 원인이 된다. 따라서, 혐기-호기공정과 조합하면 색도성분 제거 및 막 오염의 원인이 되는 유기물 및 용존성 고형물을 제거하고, 막 오염의 억제를 통한 후 수염의 연장은 물론, 처리수의 수질향상에 활용될 수 있을 것으로 사료된다.1로 강구와 함께 공구강 vial에 장입 후, Spex mixer/mill을 이용하여 기계적 합금화 하였다. 기계적 합금화 공정으로 제조한 분말에 대한 X-선 회절분석과 시차 열분석으로 합금화 정도를 분석하였다. (Bi1-xSbx)2Te3 및 Bi2(Te1-ySey)3 합금분말을 10-5 torr의 진공중에서 300℃∼550℃의 온도로 30분간 가압소결하였다. 가압소결체의 파단면에서의 미세구조를 주사전자현미경으로 관찰하였으며, 상온에서 가압소결체의 열전특성을 측정하였다. (Bi1-xSbx)2Te3의 기계적 합금화에 요구되는 공정시간은 Sb2Te3 함량에 따라 증가하여 x=0.5 조성에서는 4 시간 45분, x=0.75 조성에서는 5 시간, x=1 조성에서는 6 시간 45분의 vibro 밀링이 요구되었다. n형 Bi2(Te1-ySey)3 합금분말의 제조에 요구되는 밀링시간 역시 Bi2Se3 함량 증가에 따라 증가하였으며 Bi2(Te0.95Se0.05)3 합금분말의 제조에는 2시간, Bi2(Te0.9Se0.1)3 및 Bi2(Te0.85Se0.15)3 합금분말의 형성에는 3시간의 bivro 밀링이 요구되었다. 기계적 합금화로 제조한 p형 (Bi0.2Sb0.8)2Te3 및 n형 Bi2(Te0.9Se0.1)3 가압 소결체는 각기 2.9x10-3/K 및 2.1x10-3/K 의 우수한 성능지수를 나타내었다.ering)가 필수적이다. 그러나 침전법에서 얻게 되는 분말은 매우 미세하여 colloid를 형성하게 되며, 이러한 colloid 상태의 미세한 침전입자가 filte

  • PDF

Magnetic and Electric Transport Properties of MnTe Thin Film Grown by Molecular Beam Epitaxy (분자선 증착법에 의해 성장한 MnTe 박막의 자기적 및 전기수송 특성)

  • Kim, Woo-Chul;Bae, Sung-Whan;Kim, Sam-Jin;Kim, Chul-Sung;Kim, Kwang-Joo;Yoon, Jung-Bum;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • MnTe layers of high crystalline quality were successfully grown on Si(100) : B and Si(111) substrates by molecular beam epitaxy (MBE). Under tellurium-rich condition and the substrate temperature around $400^{\circ}C$, a layer thickness of $700{\AA}$ could be easily obtained with the growth rate of $1.1 {\AA}/s$. We investigated the structural, magnetic and transport properties of MnTe layers by using x-ray diffraction (XRD), superconducting quantum interference device (SQUID) magnetometry, and physical properties measurement system (PPMS). Characterization of MnTe layers on Si(100) : B and Si(111) substrates by XRD revealed a hexagonal structure of polycrystals with lattice parameters, ${\alpha}=4.143{\pm}0.001{\AA}\;and\;c=6.707{\pm}0.001{\AA}$. Investigation of magnetic and transport properties of MnTe films showed anomalies unlike antiferromagnetic powder MnTe. The temperature dependence of the magnetization data taken in zero-field-tooling (ZFC) and field-cooling (FC) conditions indicates three magnetic transitions at around 21, 49, and 210 K as well as the great irreversibility between ZFC and FC magnetization in the films. These anomalies are attributable to a magnetic-elastic coupling in the films. Magnetization measurements indicate ferromagnetic behaviour with hysteresis loops at 5 and 300 K for MnTe polycrystalline film. The coercivity ($H_c$) values at 5 and 300 K are 55 and 44 Oe, respectively. In electro-transport measurements, the temperature dependence of resistivity revealed a noticeable semiconducting behaviours and showed conduction via Mott variable range hopping at low temperatures.

The Design of BPF with Dielectric Resonators (DR을 이용한 대역통과 필터 설계)

  • Kang, Eun Kyun;Jeon, Hyung Jun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.128-132
    • /
    • 2017
  • In this thesis, a BPF(band-pass filter) at the center frequency of 2.14GHz, and bandwidth of 20MHz is designed and implemented using high Q dielectric resonators with ${\varepsilon}_r=38$. The DR(dielectric resonator) is resonated by $TE_{01{\delta}}$-mode and it has a hole in the center of DR. The BPF consists of 6-poles dielectric resonators and the characteristic of elliptic function is obtained by non-adjacent coupling. It has the average insertion loss of 0.97dB and the return loss over 25dB in its passband. In this thesis, the frequency selectivity is more improved by the coupling characteristics between non-adjacent resonators than that of dielectric resonator filters with a Chebyshev response.

Antibiotic Susceptibility of Salmonella spp. Isolated From Diarrhoea Patients in Seoul From 1996 to 2001 (서울 시내 설사환자에서 분리한 살모넬라의 항생제 감수성의 년도별 변화 추이)

  • 박석기;박성규;정지헌;진영희
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.2
    • /
    • pp.61-70
    • /
    • 2002
  • In order to investigate the classification and antibiotic resistance of Salmonella species,718 isolates were isolated from patient in Seoul from 1996 to 2001. The two hundred and ninety eight isolates (41.5%) were identified as Sal. Enteritidis, followed by Sal. Typhi 218 isolates (30.4%), and Sal. Typhimurium 87 isolates (12.1%). The identified Salmonella species were most resistant to tetracycline (32.7%), followed by streptomycin (28.0%), ticarcillin (18.1%) and ampicillin (12.4%). Among isolates,34.7% of Sal. Enteritidis were resistant to tetracycline, 32.3% to streptomycin,23.2% to ticarcillin,13.5% to ampicillin, respectively. 13.8% of Sal. Typhi were resistant to streptomycin,10.6% to tetracycline, respectively.66.7% of Sal. Typhimurium were resistant to tetracycline, 42.5% to streptomycin, 28.7% to ticarcillin, 26.4% to ampicillin and 17.2% to chloramphenicol, respectively. Of 718 isolates, 324 isolates (45.1%) were resistant to 1 or more drugs and 64 isolates (19.8%) were resistant to 1 drug, 132 isolates (40.7%) were resistant to 2 drugs,50 isolates (15.4%) were resistant to 3 drugs, 27 isolates (8.3%) to 4 drugs,27 isolates (8.3%) to 5 drugs,22 Isolates (6.8%) to 6 drugs. The most prevalent multiple resistant pattern was tetracycline-kanamycin (35.5%), followed by tetracycline-kanamycin-ticarcillin (8.3%), and tetracycline-kanamycin-ticarcillin-ampicillin (7.4%) . Antibiotic resistant rate of Sal. Typhimurium was 73.6%,1311owe4 by Sal. Enteritidis 53.7% and Sal. Typhi 19.3%. Most Sal. Enteritidis was resistant to 1 drug o.2 drugs, whereas Sal. Typhi. and Sal.. Typhunurium were more .resistant to 5 (16.7%) or 6 drugs (26.6%). The old generation antibiotics such as ampicillin, tetracycline, and streptomycin were annually more resistant than the new generation antibiotics such as ceftriaxone, ciprofloxacin or cefoxitin.

TE-TM Mode Conversion in Thin- Film Optical Wave-guides with Gyrotropic and Anisotropic Materials (박막형 광도파관에서 이방성 매질에 의한 TE-TM 모드 변환)

  • 정상구;원영희
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.17-32
    • /
    • 1982
  • Wave propagation in gyrotropic or anisotropic medium is analyzed in terms of the eigenmodes of the medium, which are admixture of TE and TM waves. The field composition and the phase velocity of the modes are also determined. The results of the analysis are applied to thin film optical waveguide using such medium as substrate and/or film. Based on the characteristic equations for phase constants of the waveguide, the condition for TE-TM mode convection is derived, and wave propagation in the guide is represented in the form of Jones matrix, which allows a new interpretation in the conversion efficiency of the thin-film optical waveguides.

  • PDF

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Evaluations of Inhomogeneous Shimming in $^1$H MR Spectroscopy (자기공명분광에서 비균질 자장보정에 관한 평가)

  • Choe, Bo-Young;Baik, Hyeon-Man;Suh, Tae-Suk;Lee, Hyoung-Koo;Chun, Heung-Jae;Shim, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.73-83
    • /
    • 2000
  • In this study, we investigate the effects of poor shimming on quantitative measurement of ratios of metabolite levels by proton magnetic resonance spectroscopy ($^1$H MRS). Coefficient of variation (COV) of metabolite ratios for point resolved spectroscopy (PRESS) and stimulated-echo acquisition mode (STEAM) spectra was evaluated from a phantom containing in vivo levels of metabolites using a conventional whole body 1.5T MR system and conventional acquisition and analysis protocol. A statistical P-value was also calculated from a linear regression for relationship of metabolite ratios. N-acetylaspartate (NAA)/ creatine (Cr) and NAA/ choline (Cho) had low COV values for the long and short TE spectra (29.1 and 27.5%; 23.8 and 12.6 %), whereas Cho/Cr and Cr/Cho had high COV values (50.0 and 68.6 %; 27.5 and 29.3 %). A linear relationship between NAA/Cr and Cho/Cr, and between NAA/Cho and Cr/Cho revealed the statistical significance in the long and short TE spectra, respectively (P < 0.0001 and P < 0.0001; P = 0.015 and P = 0.005). There was no significant relationship between Cho/NAA and Cr/NAA in the measurement (P = 0.159; P = 0.910). The present study suggested that NAA/Cr and NAA/Cho could be useful for data with poor shimming in $^1$H MR spectroscopy. In conclusion, statistical significance of metabolite ratios indicated that the Cr and Cho levels could be interpreted as a significant alteration factor in the long and short TE spectra, and then should be used with care to provide precise metabolite quantification.

  • PDF

Thermoelectric Characteristics of the p-type $(Bi,Sb)_2Te_3$ Nano-Bulk Hot-Pressed with Addition of $ZrO_2$ as Nano Inclusions ($ZrO_2$를 나노개재물로 첨가한 p형 $(Bi,Sb)_2Te_3$ 나노벌크 가압소결체의 열전특성)

  • Yeo, Y.H.;Kim, M.Y.;Oh, T.S.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.3
    • /
    • pp.51-57
    • /
    • 2010
  • Thermoelectric properties of the p-type $(Bi,Sb)_2Te_3$, hot-pressed with the $(Bi,Sb)_2Te_3$ powders fabricated by melting/grinding method, were characterized with variation of the hot-pressing conditions. Thermoelectric characteristics of the hot-pressed $(Bi,Sb)_2Te_3$ were also analyzed with addition of $ZrO_2$ as nano inclusions. With increasing the hotpressing temperature from $350^{\circ}C$ to $550^{\circ}C$, Seebeck coefficient and electrical resistivity decreased from 275 ${\mu}V$/K to 230 ${\mu}V$/K and 6.68 $m{\Omega}$-cm to 1.86 $m{\Omega}$-cm, respectively. The power factor decreased with addition of $ZrO_2$ nano powders more than 1 vol%, implying that the optimum amount of $ZrO_2$ nano inclusions to get a maximum power factor would be less than 1 vol%.