• Title/Summary/Keyword: TC4

Search Result 1,981, Processing Time 0.031 seconds

A Microstrip Bandpass Filters Using Dual-Behavior Resonators Integrated with EBG Structures to Improve Stopband Response (저지대역 개선을 위해 EBG구조를 집적한 DBR 마이크로스트립 대역통과 여파기)

  • Seok Chang-Heon;Jang Jae-Sam;Lim Jung-Sup;Hwang Ho-Soon;Jung Young-Ho;Lee Dong-Cheol;Lee Min-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.7 s.349
    • /
    • pp.162-169
    • /
    • 2006
  • A Micorstrip Bandpass Filter Using DBRs for WLAN ($2.3{\sim}2.4GHz$) applications is designed and an EBG structure is employed in the ground plane of the filter to suppress the stopband responses of the filter. The number of DBRs is chosen as two in consideration of low insertion loss and small size of two filter. The center frequency of the filter to be designed is 2.35GHz and its bandwidth is 140MHz. The responses of two kinds of DBR filters (one with EBG and the other without EBG) are calculated and compared with the measurements. The experimental results are in good agreement with the calculations: The bandwidth and insertion loss of the filter with EBG structure are 3.8% and 1.7dB respectively, while those of the filter without EBG structure are 7% and 1.23dB. It is shown that the insertion loss of the filter is increased and its bandwidth is deceased due to the EBG structure. Also the stopband responses of the filters with EBG structures are shown to be much improved compared with those without EBG.

The Effects of Pharmacopuncture(Eugenia caryophyllata $T_{HUNB.}$) on the High Fat Diet-induced Obese ICR Mice (정향약침(丁香藥鍼)이 고지방 식이 유발 비만 백서(白鼠)에 미치는 영향)

  • Kim, Sung Jin;Lee, Hyun Jong;Lee, Bong Hyo;Lee, Yun Kyu;Lim, Seong Chul;Jung, Tae Young;Kim, Jae Soo
    • Journal of Acupuncture Research
    • /
    • v.30 no.3
    • /
    • pp.75-85
    • /
    • 2013
  • Objectives : The purpose on this study is to show the anti-obesity effect of Eugenia caryophyllata $T_{HUNB.}$ pharmacopuncture in mice fed a high fat diet. Methods : Male ICR mice were divided into three groups, which were fed a normal AIN diet(N), a high fat diet(CT), a high fat diet and injected with 50 mg/kg of Eugenia caryophyllata $T_{HUM.}$ pharmacopuncture(EC) for 8 weeks. Results : 1. The levels of body weight gains were significantly increased in CT compared with N and decreased in EC compared with CT. 2. The levels of absolute liver weight and adipose-tissue weight were significantly decreased in EC compared with CT. The levels of relative adipose-tissue weight were significantly decreased in EC compared with CT. 3. The levels of total cholesterol(TG), triglycerid(TC), high density lipoprotein(HDL) cholesterol and low density lipoprotein(LDL) cholesterol were significantly increased in CT compared with N and decreased in EC compared with CT. The levels of HDL/LDL ratio were shown there were no significant differences in all groups. 4. The levels of adiponectin in serum were remarkably decreased in CT compared with N and significantly increased in EC compared with CT. 5. The levels of measuring adipocyte number in adipose tissue was significantly decreased in CT compared with N and increased in EC compared with CT. Conclusions : These results suggest that Eugenia Caryophyllata $T_{HUNB.}$ has an anti-obesity effect in mice and that the effect is mediated by inhibition of fat gain.

THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS (치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 -)

  • Lee Yong-Keun;Lee Keon-Il;Jung Sung-Woo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

Design of Carrier Recovery Circuit for High-Order QAM - Part I : Design and Analysis of Phase Detector with Large Frequency Acquisition Range (High-Order QAM에 적합한 반송파 동기회로 설계 - I부. 넓은 주파수 포착범위를 가지는 위상검출기 설계 및 분석)

  • Kim, Ki-Yun;Cho, Byung-Hak;Choi, Hyung-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.11-17
    • /
    • 2001
  • In this paper, we propose a polarity decision carrier recovery algorithm for high order QAM(Quadrature Amplitude Modulation), which has robust and large frequency acquisition performance in the high order QAM modem. The proposed polarity decision PD(Phase Detector) output and its variance characteristic are mathematically derived and the simulation results are compared with conventional DD(Decision-Directed) method. While the conventional DD algorithm has linear range of $3.5^{\circ}{\sim}3.5^{\circ}$, the proposed polarity decision PD algorithm has linear range as large as $-36^{\circ}{\sim}36^{\circ}$ at ${\gamma}-17.9$. The conventional DD algorithm can only acquire offsets less than ${\pm}10\;KHz$ in the case of the 256 QAM while an analog front-end circuit generally can reduce the carrier-frequency offset down to only ${\pm}100\;KHz$. Thus, in this case additional AFC or phase detection circuit for carrier recovery is required. But by adopting the proposed polarity decision algorithm, we can find the system can acquire up to ${\pm}300\;KHz$at SNR = 30dB without aided circuit.

  • PDF

Effects of Music Rope-Skipping exercise on health fitness, blood lipids and growth-related factors in male middle school Boys (음악줄넘기가 남자중학생의 건강체력, 혈중지질, 성장관련인자에 미치는 영향)

  • Kim, Jong-Won;Kim, Do-Yoen;Kang, Du-Wang;Oh, Deuk-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3405-3416
    • /
    • 2012
  • The purpose of this study was to find out the effects of music rope-skipping on health fitness, blood lipids and growth-related factors in male middle school students. For this purpose, twenty subjects were participated in this study and the participants were 'After School Class' boys in B middle school located in Gimhae City. They divided into exercise group(n=10) and control group(n=10). Exercise group conducted 45minutes per a day, four times a week for 12 weeks. And the control group continued their normal life. The results were as follows; First, in exercise group, lean body mass, muscular strength, muscular endurance, cardiovascular endurance and flexibility were all significantly increased after program execution. But %body fat was significantly decreased. In control group, muscular strength, muscular endurance and cardiovascular endurance were significantly increased. There were significant differences in lean body mass, %body fat, muscular strength and flexibility between two groups after program execution. Second, in exercise group, HDL-C was significantly increased after program execution. In control group, TG was significantly decreased. But HDL-C was significantly increased. There were no significant differences in all blood lipids(TC, TG, HDL-C and LDL-C) between two groups after program execution. Third, in exercise group, GH and IGF-I were significantly increased after program execution. In control group, IGF-I was significantly decreased. There were significant differences in IGF-I between two groups after program execution. These results indicate that music rope-skipping is effective to improve lean body mass, muscular strength, flexibility, GH and IGF-I in normal middle school male students.

SINR Maximizing Collaborative Beamforming with Enhanced Robustness Against Antenna Correlation (안테나 간 상관도에 강건한 SINR 최대화 협력적 빔포밍 기법)

  • Kim, Jae-Won;Sung, Won-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.4
    • /
    • pp.95-103
    • /
    • 2009
  • In this paper, a generation method of transmit and receive beamforming vectors based on base station cooperation is proposed which maximizes the user SINR in mobile cellular multi-user MIMO systems. There are two main sources of interference which deteriorate the performance of the system, i.e. the inter-user interference caused by the usage of the same radio resource for multiple users in the system, and the inter-cluster interference from neighboring base stations which are not participating in cooperative transmission. The proposed scheme cancels out the inter-user interference by using the block diagonalization(BD) method, and mitigate the inter-cluster interference by using optimal transmit and receive beamforming vectors based on optimal combining(OC) with the statistic information of inter-cluster interference. We perform computer simulations to verify the performance of the proposed scheme, and compare the result to the conventional performance obtained from utilizing the receiver side information only or utilizing the information from neither sides. The performance evaluations are conducted not only over the independent MIMO channels, but over correlated MIMO channels to demonstrate the robustness of the proposed scheme over the channels with correlation among antennas.

Variation on Estimated Values of Radioactivity Concentration according to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.645-653
    • /
    • 2021
  • With the recent development of precision medicine(Theranostics), interest and utilization of the quantitative function of SPECT/CT are increasing. This study aims to investigate the effect on the radioactivity concentration estimate by the increase or decrease in the total time of SPECT/CT imaging conditions. A standard image was obtained by the conditions of a total acquisition time of 600 sec(10 sec/f × 120 frames) by diluting 99mTc 91.76 MBq in a cylindrical phantom filled with sterile water, and a comparative image was obtained by increasing the total acquisition time by -90%, -75%, -50%, -25%, +50%, +100%. The CNR, radioactive concentration estimate(cps/ml), and the variation rate(%) of the recovery coefficient(RC) were analyzed by measuring the overall coefficient of interest in each image. The results[CNR, Radiation Concentration, RC] by the change in the number of projections for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results[CNR, Radiation Concentration, RC] by the acquisition time change for each increase or decrease rate(-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at -90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Image quality(CNR) showed a pattern of change in proportion to the increase or decrease in the total acquisition time of SPECT/CT, but the result at quantitative evaluation showed a change of less than 5% in all experimental conditions, maintaining quantitative accuracy(RC less than 0.05) without much influence.

Non-alcoholic fatty liver protective effects, and studies on the mechanism of action of Crataegi Fructus (산사의 NAFLD 보호 효과 및 그 작용기전에 관한 연구)

  • Kim, Min-Chul;Kong, Ryong;Han, Hyoung-Sun;Kang, Dam-hee;Lee, Seung-Jin;Lee, Cheon-Cheon;Wang, Seo;Kwon, Dong-Yeul;Kang, Ok-Hwa
    • The Korea Journal of Herbology
    • /
    • v.33 no.6
    • /
    • pp.61-70
    • /
    • 2018
  • Objectives : Non-alcoholic fatty liver disease (NAFLD) is characterized by the accumulation of hepatic triglycerides (TG) that leads to inflammation and fibrosis. Crataegi Fructus ethanol extract (CE) is a korean traditional herb that used for digestive diseases. It has been investigated that CE has the effect that prevent hepatotoxicity caused by CCl4 or GaIN and regulate the inflammatory in several organs. However, a hypolipidemic effect of CF has not been reported. Methods : The purpose of this study is that examine the lipid accumulation inhibitory effect of CE on NAFLD. We checked the body and liver weight change of MCD-diet induced mice with/without administration of CE. The blood lipid levels of C57BL/6J mice were checked by biochemistry. Also we observed the liver histology of MCD-diet induced mice and investigate the molecular mechanisms in MCD-diet-induced NAFLD in C57BL/6J mice. Results : CE improved MCD-diet-induced lipid accumulation and TG and TC levels. Also, CE decreased hepatic lipogenesis such as SREBP-1, $C/EBP{\alpha}$, $PPAR{\gamma}$, ACC and FAS. Besides, we also found out that CE increased AMPK phosphorylation. These results indicated that CE has the same ability to activate AMPK and then reduce SREBP-1, and FAS expression, finally leading to inhibit hepatic lipogenesis and hepatic antioxidative ability. Conclusions : In this report, we found CE exerted a regulatory effect on lipid accumulation by decreasing lipogenesis in MCD-diet induced NAFLD model. Therefore, CE extract may be active in the prevention of fatty liver.

The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images (SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교)

  • Kim, Ji-Hyeon;Lee, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

Analysis of the road surface runoff at the continuous section (연속구간 도로의 표면흐름 분석)

  • Kim, Jung Soo;Jo, Jun Beom;Kim, Soo Youl;Lee, Sung Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.242-242
    • /
    • 2020
  • 도시화와 산업화에 따른 유출환경의 변화로 인해 도심지에서 발생하는 대부분의 유출은 도로표면을 따라 이동하고 도로변에 설치된 빗물받이에 의해 배수된다. 이 때 빗물이 원활하게 배수되지 않아 노면수가 정체되고, 이 노면수가 인근 주택지로 유입되어 침수 피해가 발생한다. 이러한 현상은 유출량이 집중되는 도심지 저지대에서 주로 발생하며 설계 한도를 초과하지 않는 정상적인 강우 조건에서도 빈번히 나타나고 있다. 이는 최근의 기후 변화로 인한 집중 호우 등을 고려하여 설계 기준이 지속적으로 조정되어야 함과 동시에 도로 노면수의 배수 능력 평가를 위한 실제적인 연구가 이루어져야 한다는 필요성을 나타내고 있다. 특히 도로 빗물받이의 효율은 주로 종경사 및 횡경사 등의 도로 조건, 표면 유출 우수량, 빗물받이의 형상 등에 의존한다. 그러므로 상향된 설계빈도 및 도로 조건을 고려한 도로 표면 유출에 대한 흐름 분석과 빗물받이 특성을 고려한 실증연구의 분석 및 설계 해석 알고리즘의 개발이 시급한 실정이다. 본 연구에서는 도로 노면수의 배수 능력 증대를 위해 연속 설치된 빗물받이 조건 및 도로 경사조건을 고려하여 도로 배수시설의 표면 유출 모델 설계 알고리즘을 개발하였다. 표면 유출 유량은 도로의 차선(2~4차선), 경사(종경사 2~10% 및 횡경사 2~10%) 및 설계빈도(최대 30년)를 고려하였으며 유량이 노면 진행방향을 따라 연속적으로 증가하는 부등류 흐름 해석 방법을 채택하였다. 또한, 빗물받이 설치간격(L)과 도로의 폭(W)의 곱으로 계산되는 단순 직사각형 형태의 노면 형상이 아닌 도로 종경사 및 횡경사에 따른 유달거리를 산정하여 평행사변형 형태의 노면 형상을 계산하고 이에 따른 면적(A), 도달시간(tc) 및 강우강도(I)를 산정하였다. 이와 같은 1차원 흐름분석을 통해 도로 표면흐름 및 빗물받이 설치 간격을 제시하고 기존의 제시된 빗물받이 설치 간격과 비교하여 본 연구에서 제시한 설계 알고리즘을 검증하였다. 또한, 수리 실험을 통해 측정된 빗물받이 차집효율을 이용하여 연속 구간에서의 도로 표면 유출 모델의 적용성을 제시하였다. 이는 빗물받이 유입구를 통해 모든 유량이 유출된다고 가정하고 단독 구간에서의 수리분석 결과만을 고려하여 이를 확장시켜 개발된 기존의 도로 표면 유출 모델을 보완할 수 있을 것으로 기대된다. 본 연구에서 제시하고 있는 설계 알고리즘을 적용한다면 도로 전체 구간에서의 흐름 변화 분석과 배수효율의 정량적인 분석이 가능하므로 향후 도로 표면 침수 피해 저감 및 배수능력 증대를 위한 실증적이고 정량적인 분석 방법이 될 것으로 판단된다.

  • PDF