• 제목/요약/키워드: TAH

검색결과 85건 처리시간 0.027초

다중 체적 가시 기법을 이용한 완전인공심장의 가상 수술 (TAH(Total Artificial Heart) Virtual Surgery Using Multi-Volume Visualizing Technique)

  • 이동혁;김종효;김남국;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.587-589
    • /
    • 1997
  • The virtual surgical trial of TAH is very important in some points as follows. The chests of patients who is under heart-disease are various types of undefine form. It is hard to say that there exist the standard shape of TAH and the position to surgern. So, the virtual surgery system is very important in realizing TAH surgery of human. We have implemented virtual surgery system of TAH that supporting multi volume fitting trial. We have acquired CT images of patients with DICOM format. Each organ of patients was segmented in 2-dimensional CT images. 3-dimensional objects were made with marching cube algorithm and save as file in VRML format. Virtual fitting trial was performed on Cosmo-World; a VRML editor. The collision points of TAH with other organs were well observed. And the best position and angles were determined and saved or each case. We believed that this virtual surgery will be helpful in TAH surgery and TAH customizing.

  • PDF

Epoxylite Influence on Field Electron Emission Properties of Tungsten and Carbon Fiber Tips

  • Alnawasreh, Shady S;Al-Qudah, Ala'a M;Madanat, Mazen A;Bani Ali, Emad S;Almasri, Ayman M;Mousa, Marwan S
    • Applied Microscopy
    • /
    • 제46권4호
    • /
    • pp.227-237
    • /
    • 2016
  • This investigation deals with the process of field electron emission from composite microemitters. Tested emitters consisted of a tungsten or carbon-fiber core, coated with a dielectric material. Two coating materials were used: (1) Clark Electromedical Instruments Epoxylite resin and (2) Epidian 6 Epoxy resin (based on bisphenol A). Various properties of these emitters were measured, including the current-voltage characteristics, which are presented as Fowler-Nordheim plots, and the corresponding electron emission images. A field electron microscope with a tip (cathode) to screen (anode) distance of 10 mm was used to electrically characterize the emitters. Measurements were carried out under ultra-high vacuum conditions with a base pressure of $10^{-6}$ Pascal ($10^{-8}$ mbar).

자궁근종에 의한 전자궁적출술 적응증 환자의 보존적 한방치료 증례 (A Clinical Study of Uterine Myoma Cases For Total Abdominal Hysterectomy(TAH))

  • 정민영;손영주
    • 대한한방부인과학회지
    • /
    • 제19권4호
    • /
    • pp.256-268
    • /
    • 2006
  • Purpose : The purpose of this study was to investigate the clinical application of Traditional Korean Medicine(TKM) treatment to uterine myoma for TAH. Methods : Two patients were diagonosed as uterine myoma for TAH in other Obstetrics & Gynecology hospital. They were treated by herbal medicine with each diagonosis in our hospital, and the first case was also treated by acupuncture, moxibustion and herbal acupuncture. Results : After TKM, the uterine myoma size of the first case was reduced($12.2^{\ast}7.3cm{\to}9^{\ast}7cm$) significantly. And all the symptom of uterine myoma, Gonadotropin-releasing hormone(Gn-RH)'s side effects were improved. The metrorrhagia of the second case was stopped, and was not repeated during six month. The second symptoms of metrorrhagia were improved. So, the two cases don't need to have a TAH. Conclusion : The results indicate that TKM can be effective for the management of uterine myoma for TAH without operation. Further study will be investigated in TKM for healing uterine myoma for TAH completely.

  • PDF

4차원 체적 가시화 기법을 이용한 인공심장의 Fitting Trial (TAH(Total Artificial Heart) Fitting Trial Supported by 4D Volume Visualization Technique)

  • 이동혁;김종효;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.161-162
    • /
    • 1997
  • It is very useful to perform the surgery simulation before implanting TAH(Total Artificial Heart} in a patient. The space of chest and the shape of vessels are different from patient to patient. So, It is desirable to customize a TAH design to the anatomy structure of a patient. Several studies are performed to visualize and explain the 3D structure of heart. These studies are performed using 2-dimensional ref or mated images and simple measurement. Anatomy structure of a human heart is not so simple. It is 4dimensional structure ; 3-dimensional plus time, heart beating. 3-dimensional reconstruction schemes of medical images developed for about 10 years are usually categorized into two types of rendering technique ; surface rendering and volume rendering. Volume rendering is preferable in medical image processing field because this technique can be applied without considering the complexity of geometry and change of field of interest. The usable space in the chest of patient can be measured by 3D volume matching of patient trunk and TAH model. This space changes with time. In this research we have developed the 4-dimensional volume match program of patient and TAH model. 3-dimensional rendered set of volumes along time were used to simulate TAH fitting trial. The quantitative measurement from this simulation could be applied to customize TAH design.

  • PDF

The Effects of Dielectric Coatings on Electron Emission from Tungsten

  • Al-Qudah, Ala'a M.;Alnawasreh, Shady S.;Madanat, Mazen A.;Trzaska, Oliwia;Matykiewicz, Danuta;Alrawshdeh, Saad S.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • 제47권1호
    • /
    • pp.36-42
    • /
    • 2017
  • Field electron emission measurements were performed on dielectric-coated tungsten emitters, with apex radii in the nanometer and micrometer range, which were prepared by electrochemical etching in NaOH solution. Measurements were performed in a field electron microscopy (FEM) with a base pressure <$10^{-6}$ Pascal ($10^{-8}$ mbar). Four different types of dielectric were used, namely: (1) Clark Electromedical Instruments epoxylite resin, (2) Epidian 6 produced by Ciech Sarzyna S. A., (3) a Radionox solution of colloidal graphite; and (4) Molyslip 2001 E compound ($MoS_2$ and MoS). Current-voltage measurements and FEM images were used to investigate the characteristics of these composite emitters, and to assess how the different types of dielectric coating affect the suitability of the composite emitter as a potential electron source.

한국형 인공심장내의 심실간 압력 측정시스템의 개발 (Development of an Interventricular Pressure Measurement System or the Korean Total Artificial Heart)

  • 최성욱;안재목;조영호;엄경식;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.126-130
    • /
    • 1997
  • In the development of the totally implantable artificial heart (TAH), the information of the preload condition is important to ind appropriate condition or the automatic control of the heart. Our TAH configuration consists of two artificial ventricles, and brushless DC motor within actuator. The pressure between ventricles could indicate the preload condition during the TAH operation. If we can measure accurately inspite of the noise induced from TAH and environmental condition. We suggested integrating a feedback loop to remove an unexpected DC drift. NPI 19-series Nova sensor was used which could measure pressure in gas and liquid. This method and sensor enabled us to develop the pressure transducer compact so (that) the systems can be implanted with TAH into patient. This system has been verified in vitro and in vivo test. This results showed that the output waveform of this system was stable irrespective of animal condition.

  • PDF

모터구동형 완전이식 인공심장에서 전류파형의 분석에 의한 심박출량 자동제어 알고리즘의 개발 (A Study On the Automatic Cardiac Output Control Without Pressure Sensors for the motor-driven Totally Implantable TAH Using Motor-Current Waveform Analysis)

  • 최원우;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.130-135
    • /
    • 1992
  • In this paper a new cardiac output control method without pressure sensors is presented for the rotor-driven totally implantable TAH using motor-current wavelet analysis. Theoretical analysis and mock circulation system experiment results show that cardiac output of TAH, which is indeperdent of afterload and sensitively dependent to preload, is well controlled for the independently variable preload.

  • PDF

Optimal Velocity Profile for Minimum Power Consumption of Korean Total Artificial Heat

  • Chang, Jun-Keun;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.51-64
    • /
    • 1997
  • A dynamic model of the Korean total artificial heart(TAH) which contains a brushless DC motor, all of mechanical components, the pump system with integrated variable volume space(WS) and the circulatory system model including the bronchial circulation were established Two different sets of seven differential equations were separately derived for the left and right systolic period of the Korean TAH operation. Throughout the computer simulation, a full-state fEedback optimal controller that minimizes the power consumption of the Korean TAH and drives the end stage velocity of the energy converter to zero was developed based upon the optimal control theory. Robustness of the controller were also analyzed with the dynamic model of the Korean TAH.

  • PDF

일본 국립 순환기 센타형 전기유압식 인공심장의 개발과 동물실험 (Development and in Vivo Test of an Electrohydraulic Total Artificial Heart at the National Cardiovascular Center in Japan)

  • 손영상
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권2호
    • /
    • pp.163-170
    • /
    • 1998
  • 인공심장의 주된 합병증인 혈전과 감염의 문제를 줄이고 장착 환자의 삶의 질을 높이기 위하여 체내 완전 매립형 전기 유압식 인공심장을 개발하고 있는 것과 이 모델을 이용한 동물실험에 대하여 보고하는 바이다. 이 인공심장은 혈액펌프, 유압구동기, 구동제어회로, 경피적 에너지-정보 전송시스템, 체내 받테리 등으로 구성되어 있다. 실험동물은 체중 62Kg의 송아지를 이용하였다. 흉강내 이식하는데 어려움은 없었고, 수술 후 생존하는 동안 혈역학적으로 문제는 없었으며 특이한 합병증도 발생하지 않았다. 그러나 이식 11일째 기계적인 결함으로 작동이 정지하였다. 앞으로 기계적 수명이나 생체적 합성 등의 문제 등히 해결되어야 할 것이다.

  • PDF

Adverse Events in Total Artificial Heart for End-Stage Heart Failure: Insight From the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE)

  • Min Choon Tan;Yong Hao Yeo;Jia Wei Tham;Jian Liang Tan;Hee Kong Fong;Bryan E-Xin Tan;Kwan S Lee;Justin Z Lee
    • International Journal of Heart Failure
    • /
    • 제6권2호
    • /
    • pp.76-81
    • /
    • 2024
  • Background and Objectives: Real-world clinical data, outside of clinical trials and expert centers, on adverse events related to the use of SyncCardia total artificial heart (TAH) remain limited. We aim to analyze adverse events related to the use of SynCardia TAH reported to the Food and Drug Administration (FDA)'s Manufacturers and User Defined Experience (MAUDE) database. Methods: We reviewed the FDA's MAUDE database for any adverse events involving the use of SynCardia TAH from 1/01/2012 to 9/30/2020. All the events were independently reviewed by three physicians. Results: A total of 1,512 adverse events were identified in 453 "injury and death" reports in the MAUDE database. The most common adverse events reported were infection (20.2%) and device malfunction (20.1%). These were followed by bleeding events (16.5%), respiratory failure (10.1%), cerebrovascular accident (CVA)/other neurological dysfunction (8.7%), renal dysfunction (7.5%), hepatic dysfunction (2.2%), thromboembolic events (1.8%), pericardial effusion (1.8%), and hemolysis (1%). Death was reported in 49.4% of all the reported cases (n=224/453). The most common cause of death was multiorgan failure (n=73, 32.6%), followed by CVA/other non-specific neurological dysfunction (n=44, 19.7%), sepsis (n=24, 10.7%), withdrawal of support (n=20, 8.9%), device malfunction (n=11, 4.9%), bleeding (n=7, 3.1%), respiratory failure (n=7, 3.1%), gastrointestinal disorder (n=6, 2.7%), and cardiomyopathy (n=3, 1.3%). Conclusions: Infection was the most common adverse event following the implantation of TAH. Most of the deaths reported were due to multiorgan failure. Early recognition and management of any possible adverse events after the TAH implantation are essential to improve the procedural outcome and patient survival.