• Title/Summary/Keyword: T-junction

Search Result 398, Processing Time 0.024 seconds

Limit Load Solutions for Piping Branch Junctions with local wall-thinning under Internal Pressure (감육이 존재하고 내압을 받는 T 분기관의 한계하중 평가식)

  • Ryu, Kang-Mook;Kim, Yun-Jae;Lee, Kuk-Hee;Park, Chi-Yong;Lee, Sung-Ho;Kim, Tae-Ryong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1813-1817
    • /
    • 2007
  • The present work presents plastic limit load solutions for piping branch junctions with local wall-thinning, based on detailed three-dimensional (3-D) and small strain FE limit analyses using elastic-perfectly plastic materials. Three types of loading are considered; internal pressure, in-plane bending on the branch pipe and in-plane bending on the run pipe. The wall-tinning located on variable area of the piping branch junction is considered. A wide range of piping branch junction and wall-thinning geometries are considered. Comparison of the proposed solutions with FE results shows good agreement

  • PDF

Flow Characteristics for PIV Visualization at Junction Duct (PIV 가시화에 의한 합류덕트에서의 유동특성)

  • Kim, M.K.;Kwon, O.B.;Bae, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.45-50
    • /
    • 2005
  • Characteristics of flows at T-junction duct with and without orifices are investigated in this paper. Experiments and PIV visualization were carried out for several flow rates. Two-dimensional PIV experimental apparatus was decided by numerical analysis. PIV visualization was also coded to visualize flow fields at junctions for two-dimensional case. For the PIV visualization system, Grey-Level Cross-Correlation particle tracking algorithm was used to calculate the flow fields. Vinyl chloride polymer particles of $100{\sim}150{\mu}m$ of diameter are used in this visualization. The PIV visualization results showed relatively good agreement with Experimental data.

  • PDF

Operation of a Single Flux Quantum 4-stage Shift Register Fabricated with High $T_c$ Ramp-edge Junction Technology (고온 초전도 경사형 모서리 접합을 이용한 4단 쉬프트 레지스터의 동작)

  • Kim, J. H.;Park, J. H.;Kim, S. H.;Jung, K. R.;Kang, J. H.;Sung, G. Y.;Hahn, T. S.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.83-86
    • /
    • 2001
  • We have fabricated a single flux quantum 4-stage shift register with interface-controlled $Y_1$$Ba_2$$Cu_3$$O_{7-x}$(YBCO) Josephson junction. The YBCO Josephson junctions showed RSJ-like current-voltage(I-V) curves at temperatures 45~80K. We tested load and shift operation of shift register with binary data sequences “1000”, “1010”, “1011”, and “1111” at 58K. For all the binary data sequences, the shift register operated successfully. By operating the circuit with proper current pulses, we observed no errors during at least 12 hours operation for all the data sequences.s.

  • PDF

Intramedullary Spinal Cord Lipoma Extending from the Cervicomedullary Junction to the Upper Thoracic Cord

  • Lee, Deok-Gu;Yoon, Seok-Mann;Shim, Jai-Joon;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.1
    • /
    • pp.71-73
    • /
    • 2005
  • A case of intramedullary spinal cord lipoma is presented. A one month-old male infant presented with irritability and weakness on his upper extremities. A magnetic resonance[MR] image of the cervical spine demonstrated a well defined, high signal intensity lesion on both T1 and T2-weighted MR images and suppression on the fat saturation sequence. The tumor mass extended from the foramen magnum to T2 vertebra level. Ventral displacement of the spinal cord with kinking of the cervico-medullary junction was evident on the T2-weighted sagittal image. Partial resection of the tumor mass through laminoplastic laminotomy from C1 to T2 resulted in improved motor weakness on his upper extremities.

Inhibitory effect of Gardeniae Fructus extracts on oxidation and motility of keratinocytes (치자추출물이 산화 반응 및 피부각질형성 세포 운동성에 미치는 영향)

  • Kim, Ji Young;Cho, Nam Joon;Han, Hyo Sang;Kim, Kee Kwang
    • The Korea Journal of Herbology
    • /
    • v.34 no.2
    • /
    • pp.25-32
    • /
    • 2019
  • Objectives : Gardeniae Fructus extract is used as a component of various cosmetics. However, the effect of the extract on the motility of keratinocytes has not been studied. The aim of this study is to investigate the inhibitory effect of ethanol extract of Gardeniae Fructus (GFET) or ethyl acetate extract of Gardeniae Fructus (GFEA) on oxidation and motility of human keratinocyte HaCaT cells. Methods : Antioxidant activity of Gardeniae Fructus extracts were determined by the 2,2'-azino-bis-3-ethylbenzothiazoline-6-sulphonic acid (ABTS) assay. To investigate the cytotoxicity of Gardeniae Fructus extracts, 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium (MTS) assay was performed. The mRNA expression levels of tight junction related genes were analyzed using quantitative RT-PCR analysis. Cell migration assay was employed to determine the activity of Gardeniae Fructus extracts on motility of human keratinocyte HaCaT cells. Results : GFET and GFEA showed strong antioxidant activity. GFEA showed stronger cytotoxicity in HaCaT cells than GFET until $2.0mg/m{\ell}$ concentration. Cell migration assay demonstrated that GFET and GFEA decreased the motility of HaCaT cells. In addition, the mRNA expression level of claudin 8 among tight junction genes was significantly reduced by GFET or GFEA treatment. Conclusions : We investigated the physiological activities of the extracts of Gardeniae Fructus extracts on human keratinocytes by two different extraction methods. In addition, the mRNA expression level of claudin 8 among tight junction genes was significantly reduced by either GFET or GFEA treatment. This study provides basic information on the application of Gardeniae Fructus extract to cosmetics component.

The Use of Pedicle Screw-Rod System for the Posterior Fixation in Cervico-Thoracic Junction

  • Cho, Won-ik;Eid, Ahmed Shawky;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • Objective : In cervico-thoracic junction (CTJ), the use of strong fixation device such as pedicle screw-rod system is often required. Purpose of this study is to analyze the anatomical features of C7 and T1 pedicles related to screw insertion and to evaluate the safety of pedicle screw insertion at these levels. Methods : Nineteen patients underwent posterior CTJ fixation with C7 and/or T1 included in fixation levels. Seventeen patients had tumorous conditions and two with post-laminectomy kyphosis. The anatomical features were analyzed for C7 and T1 pedicles in 19 patients using computerized tomography (CT). Pedicle screw and rod fixation system was used in 16 patients. Pedicle violation by screws was evaluated with postoperative CT scan. Results : The mean values of the width, height, stable depth, safety angle, transverse angle, and sagittal angle of C7 pedicles were $6.9{\pm}1.34\;mm$, $8.23{\pm}1.18\;mm$, $30.93{\pm}4.65\;mm$, $26.42{\pm}7.91$ degrees, $25.9{\pm}4.83$ degrees, and $10.6{\pm}3.39$ degrees. At T1 pedicles, anatomic parameters were similar to those of C7. The pedicle violation revealed that 64.1% showed grade I violation and 35.9% showed grade II violation, overall. As for C7 pedicle screw insertion, grade I was 61.5% and grade II 38.5%. At T1 level, grade I was 65.0% and grade II 35.0%. There was no significant difference in violation rate between the whole group, C7, and T1 group. Conclusion : C7 pedicles can withstand pedicle screw insertion. C7 pedicle and T1 pedicle are anatomically very similar. With the use of adequate fluoroscopic oblique view, pedicle screw can be safely inserted at C7 and T1 levels.

CORRELATION OF PERICORONITIS AND ERUPTION STATE OF THE MANDIBULAR THIRD MOLAR (하악 제3대구치의 맹출 양상과 치관주위염과의 상관관계)

  • Cheong, Jeong-Kwon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.2
    • /
    • pp.161-167
    • /
    • 2006
  • Objectives: Pericoronitis was the most common indication for mandibular third molar surgery and there are no universally acceptable predictive criteria for pericoronitis occurrence. This study was designed to analyze the correlation of the pericoronitis and the eruption state of the mandibular third molar using panoramic radiographs statistically. Materials and Methods: 218 patients whose chief complaint was the extraction of the mandibular third molar were examined. The presence and absence of pericoronitis, age, sex, position of extraction site, angulation, impaction degree, position to the anterior border of mandibular ramus, distance between distal cementoenamel junction of second molar and mesial cementoenamel junction of the mandibular third molar were assessed. Then the correlation of pericoronitis and the eruption state of the mandibular third molar were analyzed by Student's t-test and chi-square test. Results: There was no correlation between Pericoronitis and age, sex, position of the mandibular third molar. The angulation(P=0.005), impaction degree(P=0.043), relation with anterior border of mandibular ramus(P=0.003), distance between distal cementoenamel junction of second molar and mesial cementoenamel junction of the mandibular third molar(P<0.05) were correlated with pericoronitis. Conclusions: The occurrence of the pericoronitis can be predicted by the eruption state of the mandibular third molar such as angulation, impaction degree, relation with anterior border of mandibular ramus, distance between distal cementoenamel junction of second molar and mesial cementoenamel junction of third molar.

Tunneling Magnetoresistance in Si/$SiO_2$/NiFe/$Al_2$$O_3$/Co Thin Films (Si/$SiO_2$/NiFe/$Al_2$$O_3$/Co 박막의 투과자기저항 특성 연구)

  • 현준원;백주열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.934-940
    • /
    • 2001
  • Magnetic properties were investigated for Si/SiO$_2$/NiFe(300 )/A1$_2$O$_3$(t)/Co(200 ) junction related with the parameters of $Al_2$O$_3$. Insulating $Al_2$O$_3$ layer was formed by depositing a 5~40 thick Al layer, followed by a 90~120s RF plasma oxidation in an $O_2$ atmosphere. Magnetoresistance was not observed for tunnel junction with 5~10 thick Al layer, but magnetoresistance was observed large for tunnel junction with 15~40 thick Al layer. Oxidation time did not largely influence magnetoresistance. Tunnel magnetoresistance effect depended on magnetization behavior of two ferromagnetic layers. Tunneling junction was confirmed through nonlinear I-V curve. In this work, tunneling magnetoresistance(TMR) up to 30 % was observed. This apparent TMR is an artifact of the nonuniform current flow over the junction in the cross geometry of the electrodes.

  • PDF

Numerical analysis of two experiments related to thermal fatigue

  • Bieder, Ulrich;Errante, Paolo
    • Nuclear Engineering and Technology
    • /
    • v.49 no.4
    • /
    • pp.675-691
    • /
    • 2017
  • Jets in cross flow are of fundamental industrial importance and play an important role in validating turbulence models. Two jet configurations related to thermal fatigue phenomena are investigated: ${\bullet}$ T-junction of circular tubes where a heated jet discharges into a cold main flow and ${\bullet}$ Rectangular jet marked by a scalar discharging into a main flow in a rectangular channel. The T-junction configuration is a classical test case for thermal fatigue phenomena. The Vattenfall T-junction experiment was already subject of an OECD/NEA benchmark. A LES modelling and calculation strategy is developed and validated on this data. The rectangular-jet configuration is important for basic physical understanding and modelling and has been analyzed experimentally at CEA. The experimental work was focused on turbulent mixing between a slightly heated rectangular jet which is injected perpendicularly into the cold main flow of a rectangular channel. These experiments are analyzed for the first time with LES. The overall results show a good agreement between the experimental data and the CFD calculation. Mean values of velocity and temperature are well captured by both RANS calculation and LES. The range of critical frequencies and their amplitudes, however, are only captured by LES.

Design and Fabrication of High Temperature Superconducting Rapid Single Flux Quantum T Flip-Flop (고온 초전도 단자속 양자 T 플립 플롭 설계 및 제작)

  • Kim, J. H.;Kim, S. H.;Jung, K. R.;Kang, J. H.;Syng, G. Y.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.87-90
    • /
    • 2001
  • We designed a high temperature superconducting rapid single flux quantum(RSFQ) T flip-flop(TFF) circuit using Xic and WRspice. According to the optimized circuit parameters, we fabricated the TFF circuit with $Y_1$$Ba_2$Cu$_3$$O_{7-x}$(YBCO) interface-controlled Josephson junctions. The whole circuit was comprised of five epitaxial layers including YBCO ground plane. The interface-controlled Josephson junction was fabricated with natural junction barrier that was formed by interface-treatment process. In addition, we report second design for a new flip-flop without ground palne.e.

  • PDF