• 제목/요약/키워드: T-Connected Transformer

검색결과 23건 처리시간 0.03초

Three-Phase 4-Wire Isolated Wind Energy Conversion System Employing VSC with a T-Connected Transformer for Neutral Current Compensation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.211-218
    • /
    • 2009
  • This paper presents a voltage and frequency controller (VFC) for a 4-wire stand-alone wind energy conversion system (WECS) employing an asynchronous generator. The proposed VF con-troller consists of a three leg IGBT (Insulated Gate Bipolar Junction Transistor) based voltage source converter and a battery at its DC bus. The neutral terminal for the consumer loads is created using a T-connected transformer, which consists of only two single phase transformers. The control algorithm of the VF controller is developed for the bidirectional flow capability of the active power and reactive power control by which it controls the WECS voltage and frequency under different dynamic conditions, such as varying consumer loads and varying wind speeds. The WECS is modeled and simulated in MATLAB using Simulink and PSB toolboxes. Extensive results are presented to demonstrate the capability of the VF controller as a harmonic eliminator, a load balancer, a neutral current compensator as well as a voltage and frequency controller.

철도 부하의 동적 특성을 고려한 전류 불평형의 분석과 보상 (Analysis and compensation of the current unbalance considering dynamic characteristic of feeding traction loads)

  • 김기표;김진오
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.54-60
    • /
    • 2003
  • 3상 전력계통에 단상 대용량의 전철부하가 접속되면 3상 전류가 불평형하게 되어 역상 전류가 흐르게 된다. 이 역상전류는 전원 측 발전기의 회전자 표면에 과전류를 발생시키며, 급전계통 및 관련 설비에 나쁜 영향을 끼치게 된다. 현재 교류 전기철도에서는 불평형 경감을 위하여 Scott결선 변압기를 채용하고 있으나 2차 극의 서로 다른 단상부하 크기 및 위상을 동일하게 일치시킬 수는 없고, 회생부하 전기차 도입과 인관 변전소 사고로 인한 연장급진도 고려해야 되기 때문에 역상전류 보상기가 필요하다. 본 논문은 기존의 전류불평형 해석방법인 정적모델 평가기법 대신에 열차운행스케줄에 따른 동적 특성을 이용한 새로운 전류불평형 평가기법을 유도하였으며, 이를 통해 부하 측의 불평형에 의해 발생하는 역상전류를 흡수하기 위한 보상기를 제안하고 실 계통에 가까운 전류불평형 문제를 분석하였다.

H-Bridge VSC with a T-Connected Transformer for a 3-Phase 4- Wire Voltage and Frequency Controller of an Isolated Asynchronous Generator

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.43-50
    • /
    • 2009
  • This paper deals with a novel solid state controller (NSSC) for an isolated asynchronous generator (IAG) feeding 3-phase 4-wire loads driven by constant power prime movers, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of the asynchronous generator. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 2-leg voltage source converters (CC- VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The neutral point of the load is created using aT-configuration of the transformers. The IAG system is modeled in MATLAB along with Simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of the isolated generating system consisting of NSSC and IAG driven by uncontrolled pico hydro turbine and feeding 3-phase 4-wire loads.

고조파 저감형 하이브리드 변압기의 성능시험 (Performance Test and Design of Harmonic Reduction Hybrid Transformer)

  • 김지호;한성호;손진근
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.277-282
    • /
    • 2014
  • Hybrid transformer means the distribution transformer, one of multi-function transformer equipped with the enhancement function of harmonics and unbalance. In other words, since existing transformer are equipped simply with transformation function only, a separated electric facility should be additionally installed in order to reduce the mutual harmonics and unbalance. Meanwhile, since hybrid transformer can perform the reduction of harmonics and unbalance as well as transformation function simultaneously through zigzag winding, it doesn't need any additional electric facility. This study addressed the issue of developing and testing the performance of a generator that would reduce the harmonics supplied to the grid when grid-connected with the output of a photovoltaic inverter for photovoltaic generation system.

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.

더블팬케이크 권선형 10kVA 고온초전도 변압기 (10kVA high $T_c$ Superconducting Power Transformer with Double Pancake Windings)

  • 이희준;차귀수;이지광;한송엽;류경우;최경당
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권2호
    • /
    • pp.65-72
    • /
    • 2001
  • This paper presents the design and test results of a 10kVA single phase HTS transformer which is operating at 77K. Double pancake windings with BSCCO -2223 HTS tape and GFRP cryostat with room temperature bore are used in the transformer. Four double pan cake windings were used in pancake windings are connected in parallel to conduct the secondary current of 45.4A. the rated voltages of each winding are 440/220V. Numerical calculation using Finite Element Method was used to evaluated the performance of each arrangement. Considering the magnetizing reactance, leakage reactance, electrical insulation and the circulating current in low voltage winding which had two windings in parallel, HLLH arrangement was finally chosen. Estimation of the AC loss, magnetizing loss and self field loss, in the design stage, where effects of perpendicular field and parallel field are considered. Room temperature bore type cryostat has been constructed and its heat loss was measured.

  • PDF

국내 교류 전기철도 급전계통 보호용 과전류 계전기 모델링 및 과부하 보호 협조에 관한 연구 (A Study on the Overcurrent Relay Modeling and Protective Coordination for Overload in Domestic AC Electrical Railway System)

  • 김현동;조규정;허승훈;김철환
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1121-1127
    • /
    • 2016
  • In this paper, modeling of overcurrent relay(OCR) to protect domestic AC electric railway Auto Transformer(AT) feeding system and operation characteristic analysis on overload condition are described. The target system of this paper is actual site where overload trip of circuit breaker occurs frequently. Because this AT feeding system is made of parallel single track which had a load(electric train) respectively, and is connected with only T phase of Scott Transformer. In addition, this system has been feeding 66kV voltage by KEPCO, not 154kV. We focus on protective coordination of Scott Transformer primary side and secondary side OCR for Korea single track AC electrical railway system in operation currently. We modeled single track AT feeding system and OCR. Also we performed faults and overload analysis for verification of OCR's setting values and system modeling. To analyze above mentioned research, we used PSCAD/EMTDC software tool.

변압기의 선간 단락사고 보호를 위한 지락비율차동 계전 알고리즘의 성능향상 방법 (Improved Ground differential relaying algorithm for the protection of a line-to-line fault of transformer)

  • 강해권;김진호;김세창;박종수;박종은
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.760-761
    • /
    • 2011
  • Ground differential relay is used to provide fast, sensitive, and selective protection for the wye connected and grounded electrical power equipment such as generators, power transformers, and grounding transformers. The ground differential protection only protects the ground faults within the protection zone, so that it can't protect the line-to-line fault. This paper proposes the algorithm to provide the protection for the line-to-line fault through the ground differential protection. The proposed algorithm detects the line-to-line fault of transformer using the comparison between the positive and the negative current, when the ground differential relay dose not operate. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various case studies.

  • PDF

345kV 변전소 주변압기 3차측용 건식형 분로리액터 개발 (The Development of Dry-type Shunt Reactor for 345kV Substation Main Transformer)

  • 안용호;박종범;송택상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.497-500
    • /
    • 2001
  • Shunt reactors are used to compensate for capacitive VARs generated by lightly loaded transmission lines or underground cables. They are normally connected to the transformer tertiary winding. Dry-type shunt reactors have the advantage compared with oil-immersed shunt reactor as followings. Lower investment and maintenance cost, No fire hazard and no environmental concerns, Simple insulation to ground, Response to transient overvoltage less severe, Linearity of inductance versus load current, Lower-acoustic noise, Easier transport and handling due to lower weight, No oil-collecting system must be provided since there is no oil that can leak into the ground.

  • PDF

Flat TR용 페라이트 코아의 고주파 동작 특성 (Study on operating characteristics of Ferrite cores for Flat TR in high frequency)

  • 한세원;조한구;류동욱;최광보
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1168-1171
    • /
    • 2003
  • In contrast to a conventional transformer, the flat transformer is made using a number of small ferrite cores. Two cores for transformer and one core for inductor, which composed one module. Many modules can be connected together to form a flat matrix transformer. This structural arrangement eliminates the single hot spot problem in conventional transformers and permits high current density pertains at high frequency. In this study, the ferrite magnetic cores of Mn-Zn system for the Flat transformer were manufactured and the electrical and magnetic characteristics of its tested. The power loss of sample FO2(Mn-Zn ferrite) sintered at $1350^{\circ}C$ was $350kW/m^3$ in test conditions of 250kHz, 200mT and $100^{\circ}C$, which showed the good power loss property in high frequency. The power loss of FO2 samples has been studied as a function of magnetic flux density and frequency. Steinmetz exponent was 2.82 at 250kHz and 2.73 at 500kHz. These results illustrated the switching of power loss mechanism in ferrite core from hysteresis losses to eddy current losses or others.

  • PDF