• 제목/요약/키워드: T axis

검색결과 845건 처리시간 0.029초

Recording natural head position using an accelerometer and reconstruction from computed tomographic images

  • Park, Il Kyung;Lee, Keun Young;Jeong, Yeong Kon;Kim, Rae Hyong;Kwon, Dae Gun;Yeon, Sunghee;Kwon, Kyung-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권4호
    • /
    • pp.256-261
    • /
    • 2017
  • Objectives: The concept of natural head position (NHP) was first introduced by Broca in 1862, and was described as a person's stable physiologic position "when a man is standing and his visual axis is horizontal." NHP has been used routinely for clinical examination; however, a patient's head position is random during cone-beam computed tomography (CBCT) acquisition. To solve this problem, we developed an accelerometer to record patients' NHP and reproduce them for CBCT images. In this study, we also tested the accuracy and reproducibility of our accelerometer. Materials and Methods: A total of 15 subjects participated in this study. We invented an accelerometer that measured acceleration on three axes and that could record roll and pitch calculations. Recorded roll and pitch data for each NHP were applied to a reoriented virtual image using three-dimensional (3D) imaging software. The data between the 3D models and the clinical photos were statistically analyzed side by side. Paired t-tests were used to statistically analyze the measurements. Results: The average difference in the angles between the clinical photograph and the 3D model was $0.04^{\circ}$ for roll and $0.29^{\circ}$ for pitch. The paired t-tests for the roll data (P=0.781) and the pitch data (P=0.169) showed no significant difference between the clinical photographs and the 3D model (P>0.05). Conclusion: By overcoming the limitations of previous NHP-recording techniques, our new method can accurately record patient NHP in a time-efficient manner. Our method can also accurately transfer the NHP to a 3D virtual model.

Difference of Position Change of Sesamoid Bones During Active Abduction Exercise of Great Toe in Subjects with Hallux Valgus

  • Yun, Sung-Joon;Kang, Min-Hyeok;Kim, Moon-Hwan
    • The Journal of Korean Physical Therapy
    • /
    • 제27권2호
    • /
    • pp.85-88
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the effects of active abduction exercise of the great toe on the medial and lateral sesamoid bones in hallux valgus (HV) patients by measuring radiography. Methods: In this study 27 young subjects were separated into two groups (normal group and HV group). Two pictures were taken by radiography while maintaining resting and while holding maximal active abduction of the great toe in sitting position on an x-ray table. All radiographs were used to measure the distance of the medial and lateral sesamoid bone from the longitudinal axis of the first metatarsal bone, respectively. Paired t-test was used for analysis of the resting and active abduction exercise in groups. Independent t-test was used to evaluate statistical significance between normal group and HV group. The statistical significance level was p<0.05. Results: In active abduction exercise of the normal group, distance of the medial and lateral sesamoid bones was not significantly different compared to resting condition. In active abduction exercise of the HV group, change of distance of the medial and lateral sesamoid bones showed statistically significant difference compared to resting condition. The distance between the medial sesamoid bone showed a more significant decrease in the HV vs. normal group, while the distance between the lateral sesamoid bone was significantly greater in the HV vs. normal group. Conclusion: These findings suggest that active abduction exercises, to reduce or prevent deterioration of the HV angle, should be considered for sesamoid bone displacement to improve muscle balance in the great toe.

Mixed-state Hall effect of $MgB_2$ thin films ($MgB_2$박막의 혼합상태에서의 홀 효과)

  • Kim, Bo-Yeon;Jung, Soon-Gil;Moon, Kyeong-Hee;Kang, W.N.;Choi, Eun-Mi;Kim, Heon-Jung;Lee, Sung-Ik;Kim, Hyeong-Jin
    • Progress in Superconductivity
    • /
    • 제7권2호
    • /
    • pp.103-108
    • /
    • 2006
  • We have measured the Hall resistivity (${\rho}_{xy}$) and the longitudinal resistivity (${\rho}_{xy}$) on superconducting $MgB_2$ thin films in extended fields up to 18 T. We found a universal scaling behavior between the Hall resistivity and the longitudinal resistivity, which is independent of the temperature and the magnetic field. At a wide magnetic field region from 1 to 18T, a universal power law of ${\beta}=2.0{\pm}0.1$ in a scaling relation, ${\rho}_{xy}={A{\rho}_{xx}}^{\beta}$, was observed in c-axis-oriented $MgB_2$ thin films. These results can be well interpreted by using recent models.

  • PDF

Design and Implementation of an Automatic System for Mixing Offset Ink (인쇄용 옵셋 잉크 자동 교반시스템의 설계 및 구현)

  • Choi, Sung-Hac;Lee, Joon-Yeol;Lee, Bong-Su;Lee, Sang-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제36권5호
    • /
    • pp.545-553
    • /
    • 2012
  • This paper reports the development of an automatic system for mixing offset printing ink. The ink mixing process is important in industrial fields where paint and ink are used. In particular, there is a demand for automating the process of producing spot colors, which involves mixing a small quantity of high-viscosity ink. The authors designed, fabricated, and experimentally tested an automatic mixing system that employs the revolution and rotation of ink and the transmission by belts. The performance of the ink mixing system was verified by conducting numerous experiments to determine the effect of rotation direction, speed, ink container axis angle, and ink amount. Conditions suitable for mixing offset ink are presented for use as guidelines for producing spot colors.

Implementation of a Fluxgate Sensor using Ferrite Ring Core (페라이트 링 코어를 사용한 fluxgate 센서의 구현)

  • Park, Yong-Woo;Kim, Ki-Uk;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • 제8권6호
    • /
    • pp.427-433
    • /
    • 1999
  • In this paper, we have presented an one-axis fluxgate magnetic sensor with ferrite core, excitation, and pick-up coil. This magnetometer is consist of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through 82 turns of the excitation coil. The second harmonic output of pick-up coil(150 turns) is measured by a FFT spectrum analyzer. This result is compared to output of PSD(phase sensitive detector) unit for detecting a second harmonic component. The measured sensitivity is about 50 V/T at driving frequency of 2 kHz. The nonlinearity of fluxgate magnetic sensor is calculated about 2.0%.

  • PDF

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • 제16권4호
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Upper critical field and superconducting anisotropy of BaFe2-xRuxAs2 (x=0.48 and 0.75) single crystals

  • Jo, Youn Jung;Eom, Man Jin;Kim, Jun Sung;Kang, W.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제16권4호
    • /
    • pp.31-35
    • /
    • 2014
  • The upper critical field ($H_{c2}$) was determined by applying a magnetic field along the ab plane and c axis for two single crystals of $BaFe_{2-x}Ru_xAs_2$ (x=0.48 and 0.75). The anisotropy of the $H_{c2}(0)$, ${\gamma}(0)=H_{c2}{^{ab}}(0)/H_{c2}{^c}(0)$, was ~1.6 for x=0.48 and ~2.3 for x=0.75. The angle-dependent resistance measured below $T_c$ allowed perfect scaling features based on anisotropic Ginzburg-Landau theory, leading to consistent anisotropy values. Because only one fitting parameter ${\gamma}$ is used in the scaling for each temperature, the validity of the ${\gamma}$ value was compared with that determined from ${\gamma}=H_{c2}{^{ab}}/H_{c2}{^c}$. The ${\gamma}$ obtained at a temperature close to $T_c$ was 3.0 and decreased to 2.0 at low temperatures. Comparing to the anisotropy determined for electron- or hole-doped $BaFe_2As_2$ using the same method, the present results point to consistent anisotropy in Ru-doped $BaFe_2As_2$ with other electron- or hole-doped $BaFe_2As_2$.

Influence of modification in core building procedure on fracture strength and failure patterns of premolars restored with fiber post and composite core

  • Kim, Young-Hoi;Lee, Jong-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.37-42
    • /
    • 2012
  • PURPOSE. The influence of the modified process in the fiber-reinforced post and resin core foundation treatment on the fracture resistance and failure pattern of premolar was tested in this study. MATERIALS AND METHODS. Thirty-six human mandibular premolars were divided into 4 groups (n = 9). In group DCT, the quartz fibre post (D.T. Light-post) was cemented with resin cement (DUO-LINK) and a core foundation was formed with composite resin (LIGHT-CORE). In group DMO and DMT, resin cement (DUO-LINK) was used for post (D.T. Lightpost) cementation and core foundation; in group DMO, these procedures were performed simultaneously in one step, while DMT group was accomplished in separated two steps. In group LCT, the glass fiber post (LuxaPost) cementation and core foundation was accomplished with composite resin (LuxaCore-Dual) in separated procedures. Tooth were prepared with 2 mm ferrule and restored with nickel-chromium crowns. A static loading test was carried out and loads were applied to the buccal surface of the buccal cusp at a 45 degree inclination to the long axis of the tooth until failure occurred. The data were analyzed with MANOVA (${\alpha}$= .05). The failure pattern was observed and classified as either favorable (allowing repair) or unfavorable (not allowing repair). RESULTS. The mean fracture strength was highest in group DCT followed in descending order by groups DMO, DMT, and LCT. However, there were no significant differences in fracture strength between the groups. A higher prevalence of favorable fractures was detected in group DMT but there were no significant differences between the groups. CONCLUSION. The change of post or core foundation method does not appear to influence the fracture strength and failure patterns.

Work Environment Monitoring of Workers Using Wearable Sensor and Helmet (착용형 센서와 헬멧을 이용한 작업자의 작업환경 모니터링)

  • Gu, Ye-Jin;Kim, Jong-Jin;Chung, Wan-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • 제20권2호
    • /
    • pp.91-98
    • /
    • 2019
  • Accidents of worker that occur in isolated places are difficult to rescue, unlike general construction accidents. There is a problem of communication limitation when an accident occurs in an isolated place. Also, it is difficult to search the accident place due to the absence of CCTV. In order to solve these problems, this paper proposes a device that combines IoT technology with a safety helmet, which must be worn in the workplace. The proposed device additionally designs and implements a real-time PPG(Photoplethysmography) sensor, body temperature sensor, accelerometer sensor and a camera sensor on the helmet. The proposed helmet system allows the user and the control center to monitor the state of the worker. In addition, when an abnormal biological signal or fall occurs to the worker, the image is transmitted to the control center. By using the proposed system, it is possible to check the status of the worker in real time, so that it has an advantage that it can cope with the accident quickly.

Magnetic Propwrties of High Quality $Nd_{12}Fe_{80}B_{6}(Nb, M)$ (M=Ti/Cu/Ga) Melt-Spun Ribbons (고특성 $Nd_{12}Fe_{80}B_{6}(Nb, M)$ (M=Ti/Cu/Ga)급속응고리본의 자기특성)

  • 김윤배;김창석;김동환;이갑호;김택기
    • Journal of the Korean Magnetics Society
    • /
    • 제2권1호
    • /
    • pp.44-49
    • /
    • 1992
  • Magnetic properties and microstructures of $Nd_{12}Fe_{80}B_{6}(Nb,\;M)$ (M=Ti/Cu/Ga) melt-spun ribbons prepared by single wheel technique have been studied. The results of microstructural study have shown that Ga is effective for the orientation of c-axis normal to the ribbon plane. The Ga-added melt-spun ribbon, $Nd_{12}Fe_{80}B_{6}(Nb,\;Ga)$, quenched at $V_{s}=17.9\;m/s$ was mostly composed of fine grains of about 30 nm in size with the textured free-side surface. The powder of this ribbon aligned in mag-netic field showd a high remanence of 0.87 T which was about 5 % higher than that of ribbon itself. It is believed that there is a possibility to fabricate a new type of HIREM melt-spun ribbon with highly textured free-side surface.

  • PDF