• Title/Summary/Keyword: T형 연결부

Search Result 8, Processing Time 0.028 seconds

An Experomental Study on the Connection of Diaphragm in Modular Bridge (조립식 교량의 가로보 연결에 관한 실험적연구)

  • Lee, Hyun Ho;Lee, Sang Seung;Cho, Doo Yong;Kim, Tae Wan;Park, Sun Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.31-39
    • /
    • 2012
  • Recently new construction and reconstruction of the bridge have been required to minimize traffic congestion, environmental disadvantage, to reduce the period of construction, and to improve the quality and workability during the construction. For this reason, the application of modular bridge system, which is assembly of the structural members, is necessary to prepare for near future. Fall of girders can occur at the moment to connect between precast girders during the construction, so appropriate cross beams should be installed to solve the mentioned problem. In this study, understanding the structural characteristics and domestic and international case of cross beam, alternative cross beam system for modular bridge was developed. To inspect the structural characteristics of the alternative system, specimens were built and static loading test was performed. Afterward, the behavior of cross beam interms of joints and load distribution was observed. Experimental results were analyzed and compared with each data. Therefore, the appropriate cross beam system for modular bridge will be chosen and proposed in this paper.

PIV Measurements of the Pressure Driven Flow Inside a T-Shaped Microchannel Junction (T헝 마이크로채널 연결부 압력구동 유동의 PIV계측)

  • Choi Jayho;Lee In-Seop
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • A custom micro-PIV optics assembly has been used to measure the flow fold inside a T-junction of a microchannel. The micro-PIV system consists of microscope objectives of various magnifications, a dichroic cube, and an 8-bit CCD camera. Fluorescent particles of diameters 620 nm have been used with a Nd:YAG laser and color filters. A programmable syringe pump with Teflon tubings were used to inject particle-seeded distilled water into the channel at flow rates of 2.0, 4.0, 6.0 mL/hr. The micro-channels are fabricated with PDMS with a silicon mold, then O$_{2}$ -ion bonded onto a slide glass. Results show differences in flow characteristics and resolution according to fluid injection rates, and magnifications, respectively. The results include PIV data with vector-to-vector distances of 2 $\mu$m with 32 pixel-square interrogation windows at 50$\%$ overlap.

  • PDF

Seismic Evaluation for Strainer in the Primary Cooling System (일차 냉각계통 스트레이너에 대한 내진 건전성 평가)

  • 정철섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.3
    • /
    • pp.295-304
    • /
    • 2000
  • To evaluate the structural integrity for the strainer under seismic loading the seismic analysis and design were performed for T-type strainer in accordance with ASME, Section Ⅲ, Class 3(ND). Since there are no specified design requirements for the strainer in ASME Code, the strainer body was analysed according to ND-3500, valve design. Flanged joints connected with PCS piping were designed according to ND-3658.3. And the criteria for the cover flange was governed by the Appendix XI. Both a frequency analysis and an equivalent static seismic analysis of the strainer were carried out using the finite element computer program, ANSYS. The frequency analysis results show the fundamental natural frequency is greater than 33Hz, thus justifying the use of the equivalent static analysis through which membrane and bending stresses are obtained in the critical points near the branch connection area. The results of the seismic evaluation fully satisfied with the structural acceptance criteria of the ASME Code. Accordingly the structural integrity on the strainer body and flanges were proved.

  • PDF

Experimental Study on Double Skin Composite Walls Subjected to Cyclic Loading (주기하중을 받는 이중강판합성벽의 실험연구)

  • Eom, Tae Sung;Park, Hong Gun;Kim, Jin Ho;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.289-301
    • /
    • 2008
  • Double skin composite (DSC) wall is a structural wall that is filed with concrete between two steel plate skins connected by tie bars. This type of wall was developed to enhance the structural performance of wall, to reduce wall thickness, and to enhance constructibility, eliminating the use of formwork and re-bars. In this study, cyclic tests were performed to investigate the inelastic behavior and earthquake resistance of isolated and coupled DSC walls with rectangular and T-shapedcross-sections. The DSC walls showed stable cyclic behaviors, exhibiting excellent energy dissipation capacity. The te st specimens failed by the tensile fracture of welded joints at the wall base and coupling beam and by the severe local buckling of the steel plate. The deformation capacity of the walls varied with the connection details at the wall base and their cross-sectional shapes. The specimens with well-detailed connections at the wall base showed relatively god deformation capacity ranging from 2.0% to 3.7% drift ratio. The load-carrying capacities of the isolated and coupled wall specimens were evaluated considering their inelastic behavior. The results were compared with the test results.

Cyclic Lond Testing for Strong Axis Joints Connected with SRC Column and RC Beams (SRC기둥-RC보 강축 접합부 상세의 구조성능 평가)

  • Moon, Jeong-Ho;Lee, Kang-Min;Lim, Jae-Hyung;Oh, Kyung-Hwan;Kim, Sung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.401-409
    • /
    • 2007
  • The objective of this research is to provide better knowledge on the behavior of strong axis SRC column-RC beam joint, supported by experimental results, that can be broadly applicable to many structures. For this purpose, firstly literature reviews and field survey were made to classify the most commonly used for these types of joints. Then, experimental program was designed and performed including 6 SRC column-RC beam joint specimens designed with various joint details. Using the experimental results obtained from the quasi-static cyclic tests, structural performances of the joints such as hysteretic curves, maximum strength capacities, strength degradation beyond the maximum strength, ductilities, and energy dissipation capacities were investigated. Test results showed that specimens with wide beam shape (RCW-P, RCW-W, RCW-F) and T beam shape (RCT-W) showed better structural performances than the bracket type specimens (HBR-L, HBR-S). These specimens also revealed to have higher strength capacities than the nominal design strength. However, H beam bracket type specimens (HBR-L, HBR-S) need further study both analytically and experimentally to verify the reason for unexpected structural performances.

Estimation of Head Loss Coefficients with Change of Invert Type in Four-Way Combining Manholes (4방향 합류맨홀 내부의 인버트 설치에 따른 손실계수 산정)

  • Ryu, Taek Hee;Kim, Jung Soo;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.465-465
    • /
    • 2016
  • 관거시설은 관거, 맨홀(manhole), 우수토실, 물받이, 연결관, 침투시설, 저류시설, 펌프장 등을 포함하는 시설들로 구성되어 있다. 여기서 맨홀은 배수시설의 유지와 관리를 위하여 일정거리마다 설치되고 있으며, 관거의 기점, 방향, 경사 및 관경이 변하는 곳, 단차가 발생하는 곳, 관거가 합류하는 곳에는 반드시 설치한다(환경부, 2011). 그러나 하수도시설기준(환경부, 2011)에서 합류맨홀의 설치에 관한 사항은 T형 합류맨홀에 관한 개략적인 표만 제시되어 있을 뿐, 4방향 합류맨홀에 대한 구체적인 설치 기준이 제시되어 있지 않은 실정이다. 또한 에너지 손실의 저감 및 배수능력을 증대시키기 위하여 맨홀내 설치되는 인버트는 미국의 형태 및 기준을 그대로 적용하고 있으므로 관거시설의 시설의 합리적인 설계기준을 제시하기 위하여 인버트가 설치된 4방향 합류맨홀에서의 흐름특성 및 수두 손실을 분석할 필요가 있다. 본 연구에서는 인버트가 설치된 4방향 합류맨홀 손실계수 산정 및 흐름특성을 분석하기 위하여 문헌조사 및 현장조사를 실시하여 수리실험 장치를 제작하였다. 실험에 사용된 맨홀은 하수도시설기준(환경부, 2011)의 표준 1호 맨홀을 1/5로 축소하였고, 인버트는 설치되지 않은 조건(CASE A), 반원형 인버트(CASE B), U형 인버트(CASE C)를 각각 실험하였으며, 실험유량으로 총 유출량 (Qout)은 $2{\sim}5{\ell}/sec$, 총 유출량에 대한 측면 유입량($Q_{Lat}$)의 비($Q_{Lat}/Q_{out}$)는 0~1 조건으로 변화시키면서 흐름특성 및 손실계수를 산정하였다. 실험결과 측면유량비가 증가함에 따라 CASE B와 CASE C는 CASE A보다 맨홀 내 수심이 약 3~7%정도 증가되는 경향을 나타내고 있었으며, 측면유량비의 증가에 따른 손실계수 산정 결과, CASE B는 CASE A 보다 약 30%정도 손실계수가 증가하였으며, CASE C는 CASE A보다 약 35%정도 손실계수가 증가하는 것으로 나타났다. 이는 기존에 사용되고 있는 인버트의 형상이 4방향 합류맨홀에서의 손실 저감 및 배수능력을 증대시키기 보다는 오히려 맨홀 내 통수능력을 저하시켜 4방향 합류맨홀에서의 배수능력을 저감시키는 것으로 분석되었다. 그러므로 기 사용되는 인버트의 개선이 필요하며 관거시설의 배수능력을 증대하기 위하여 지속적인 연구를 통한 개선된 인버트의 형상 제시가 필요할 것으로 판단된다.

  • PDF

Analysis on the Change of Haed Loss Coefficients at Four-Way Square Combining Manhole (4방향 사각형 합류맨홀에서의 손실계수 변화분석)

  • Jo, Jun Beom;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.176-176
    • /
    • 2017
  • 배수시설 내 맨홀에서의 과부하 흐름은 관거시설의 배수 능력을 저하시켜 우수의 역류로 인한 도시 침수피해의 가중 요인이 된다. 특히, 도시 유역 중 하류부의 저지대에서 주로 설치되는 합류 맨홀은 저지대 침수에 많은 영향을 미치므로 합류맨홀에서의 흐름특성 분석 및 유입유량 변화에 따른 손실계수의 변화에 관한 연구가 필요한 실정이다. 현재까지 중간맨홀, $90^{\circ}$ 접합맨홀 및 3방향(T형) 합류맨홀 등에 관한 연구는 지속적으로 수행되고 있으나 4방향 합류맨홀에 관한 연구는 기초적인 연구만 수행되고 있다. 4방향 합류맨홀은 세 개의 유입관과 한 개의 유출관으로 구성되어 있으므로 각 유입관의 유입유량 변화에 따라서 맨홀에서의 손실계수가 다양하게 변화된다. 이와 같은 유입유량 변화에 따른 맨홀 내 흐름특성 분석 및 손실계수 산정에 관한 연구는 국내에서는 전무한 실정이다. 그러므로 유입유량 변화에 따른 4방향 합류맨홀에서의 손실계수 변화특성의 분석이 필요하다. 본 연구에서는 4방향 사각형 합류맨홀에서 세방향에서 유입되는 각 유입유량의 유입비($Q_{in}/Q_{out}$)가 0.0~1.0으로 변화하는 조건에서 평균 손실계수를 산정하기 위하여 하수도시설기준(환경부, 2011)의 표준 1호 맨홀 및 연결관경을 1/5로 축소하여 수리실험 장치를 제작하였다. 유출유량은 $3{\ell}/sec$이고 각 유입관(주유입관 및 좌 우측면유입관)의 유입유량을 $0{\sim}3{\ell}/sec$까지 유입유량의 비율을 각각 10%씩 변화시키면서 수리실험을 실시하였다. 실험결과 주관거의 유입유량이 줄어들고 측면관거의 유입유량이 늘어나면서 손실계수가 상승하는 것으로 나타났으며, 한쪽 측면 관거에서만 유입유량이 들어오는 $90^{\circ}$ 접합맨홀의 형태에서 손실계수가 가장 크게 나타났으며, 유입유량 변화에 따른 4방향 합류맨홀에서의 손실계수의 범위는 0.5~1.7으로 산정되었다. 이는 과부하 4방향 사각형 합류맨홀에서는 측면 유입관에서의 유입유량의 증가에 따라 평균 손실계수 값이 크게 증가되는 것으로 판단된다. 이는 김정수(2010) 등이 산정한 $90^{\circ}$ 접합맨홀의 손실계수 및 중간맨홀의 손실계수와 유사하게 나타났으므로 전체적인 손실계수의 범위는 타당하다고 판단된다. 또한, Wang(1988) 등의 유사연구와의 유입유량 변화에 따른 손실계수의 변화 경향도 유사하였다. 따라서 본 연구에서 산정된 유입유량 변화 조건이 고려된 4방향 합류맨홀에서의 손실계수는 XP-SWMM 등의 부정류 흐름이 고려된 도시지역의 침수해석이나 관거 배수능력 평가에 활용이 가능할 것으로 판단된다.

  • PDF

Minimally invasive cardiac surgery with the partial mini-sternotomy in children (소아연령군에서의 부분흉골소절개를 통한 최소침투적심장수술)

  • 이정렬;임홍국;성숙환;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 1998
  • Purpose: The safety and efficacy of minimally invasive techniques in congenital heart surgery were tested in this study. Materal and method: Between July 1997 and November 1997, a total of 46 children were underwent minimally invasive cardiac operations at Seoul National University Children's Hospital. Age and body weight of the patients averaged 34.6${\pm}$41.8 (Range: 1∼148) months and 14.5${\pm}$9.9(Range: 3.0∼40.0) kg, respectively. Twenty eight patients were male. Preoperative surgical indications included 15 atrial septal defects, 25 ventricular septal defects, 1 foreign body in aorta, 3 partial atrioventricular septal defects, 1 total anomalous pulmonary venous connection(cardiac type), and 1 tetralogy of Fallot. After creating a small lower midline skin incision starting as down as possible from the sternal notch, a vertical midline sternotomy extended from xyphoid process to the level of the second intercostal space, where one of the T-, J-, I- or inverted C-shaped lower lying mini-sternotomy was completed with a creation of unilateral right or bilateral trap door sternal opening. A conventional direct aortic and bicaval cannulation was routine. Result: A mean length of skin incision was 6.1${\pm}$1.0(range: 4.0∼9.0) cm. A mean distance between the suprasternal notch and the upper most point of the skin incision was 4.0${\pm}$1.1 (range: 2.0∼7.0) cm. Mean cardiopulmonary bypass time, aortic cross-clamp time, and the operation time were 62.9${\pm}$20.0(range: 28∼147), 29.8${\pm}$12.8(range: 11∼79), and 161.1${\pm}$34.5 (range: 100-250) minutes. A mean total amount of postoperative blood transfusion was 71.0${\pm}$68.1 (range: 0∼267) cc. All patients were extubated mean 11.3${\pm}$13.8(range: 1∼73) hours after operation. A mean total amount of analgesics used was 0.8${\pm}$1.8(range: 0∼9) mg of morphine. The mean duration of stay in intensive care unit and hospital stay were 35.0${\pm}$32.2 (range: 10∼194) hours and 6.2${\pm}$2.0(range: 3∼11) days. There were no wound complications and hospital deaths. Conclusion: This short-term experience disclosed that the minimally invasive technique can be feasibly applied in a selected group of congenital heart disease as well as is cosmetically more attractive approach.

  • PDF