• Title/Summary/Keyword: T/T probe

Search Result 427, Processing Time 0.032 seconds

Study on characteristics of noncontact vibrating displacement sensor (비접촉식 진동 변위센서의 특성에 관한 연구)

  • Cho, C.W.;Cho, S.T.;Yang, K.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.

Low Temperature Properties of Exchange-biased Magnetic Tunnel Junction

  • Lee, K. I.;J. G. Ha;S. Y. Bae;K. H. Shin
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2000.09a
    • /
    • pp.325-326
    • /
    • 2000
  • Low temperature diagnosis was performed as a probe for the integrity of MTJ(Magnetic tunnel junction) process which is optimised for the given plasma oxidation condition. TMR ratio increased slowly with decreasing temperature than that expected from spin wave exitation theory〔1〕. Junction resistance (RJ) does not follow T$\^$-$\frac{1}{2}$/ law below 200 K, indicating another conduction path besides spin polarized tunneling is involved at low temperature. Temperature dependence of conductance dip and bias dependence of TMR with temperature are discussed, from which the quality of tunnel barrier and its formation process can be inferred.

  • PDF

Property of Nickel Silicides with Hydrogenated Amorphous Silicon Thickness Prepared by Low Temperature Process (나노급 수소화된 비정질 실리콘층 두께에 따른 저온형성 니켈실리사이드의 물성 연구)

  • Kim, Jongryul;Choi, Youngyoun;Park, Jongsung;Song, Ohsung
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.11
    • /
    • pp.762-769
    • /
    • 2008
  • Hydrogenated amorphous silicon(a-Si : H) layers, 120 nm and 50 nm in thickness, were deposited on 200 $nm-SiO_2$/single-Si substrates by inductively coupled plasma chemical vapor deposition(ICP-CVD). Subsequently, 30 nm-Ni layers were deposited by E-beam evaporation. Finally, 30 nm-Ni/120 nm a-Si : H/200 $nm-SiO_2$/single-Si and 30 nm-Ni/50 nm a-Si:H/200 $nm-SiO_2$/single-Si were prepared. The prepared samples were annealed by rapid thermal annealing(RTA) from $200^{\circ}C$ to $500^{\circ}C$ in $50^{\circ}C$ increments for 30 minute. A four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), and scanning probe microscopy(SPM) were used to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure, and surface roughness, respectively. The nickel silicide on the 120 nm a-Si:H substrate showed high sheet resistance($470{\Omega}/{\Box}$) at T(temperature) < $450^{\circ}C$ and low sheet resistance ($70{\Omega}/{\Box}$) at T > $450^{\circ}C$. The high and low resistive regions contained ${\zeta}-Ni_2Si$ and NiSi, respectively. In case of microstructure showed mixed phase of nickel silicide and a-Si:H on the residual a-Si:H layer at T < $450^{\circ}C$ but no mixed phase and a residual a-Si:H layer at T > $450^{\circ}C$. The surface roughness matched the phase transformation according to the silicidation temperature. The nickel silicide on the 50 nm a-Si:H substrate had high sheet resistance(${\sim}1k{\Omega}/{\Box}$) at T < $400^{\circ}C$ and low sheet resistance ($100{\Omega}/{\Box}$) at T > $400^{\circ}C$. This was attributed to the formation of ${\delta}-Ni_2Si$ at T > $400^{\circ}C$ regardless of the siliciation temperature. An examination of the microstructure showed a region of nickel silicide at T < $400^{\circ}C$ that consisted of a mixed phase of nickel silicide and a-Si:H without a residual a-Si:H layer. The region at T > $400^{\circ}C$ showed crystalline nickel silicide without a mixed phase. The surface roughness remained constant regardless of the silicidation temperature. Our results suggest that a 50 nm a-Si:H nickel silicide layer is advantageous of the active layer of a thin film transistor(TFT) when applying a nano-thick layer with a constant sheet resistance, surface roughness, and ${\delta}-Ni_2Si$ temperatures > $400^{\circ}C$.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

Assessment of Freeway Crash Risk using Probe Vehicle Accelerometer (프로브차량 가속도센서를 이용한 고속도로 교통사고 위험도 평가기법)

  • Park, Jae-Hong;Oh, Cheol;Kang, Kyeong-Pyo
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.49-56
    • /
    • 2011
  • Understanding various casual factors affecting the occurrence of freeway traffic crash is a backbone of deriving effective countermeasures. The first step toward understanding such factors is to identify crash risks on freeways. Unlike existing studies, this study focused on the unsafe vehicle maneuvering that can be detected by in-vehicle sensors. The recent advancement of sensor technologies allows us to gather and analyze detailed microscopic events leading to crash occurrence such as the abrupt change in acceleration. This study used an accelerometer to capture the unsafe events. A set of candidate variables representing unsafe events were derived from analyzing acceleration data obtained by the accelerometer. Then, the crash risk was modeled by the binary logistic regression technique. The probabilistic outcome of crash risk can be provided by the proposed model. An application of the methodology assessing crash risk was presented, and further research items for the successful field implementation were also discussed.

High-Frequency Modeling of Printed Spiral Coil Probes for Radio-Frequency Interference Measurement (무선주파수 간섭 측정을 위한 Printed Spiral Coil (PSC) 프로브의 고주파 모델링)

  • Kim, yungmin;Song, Eakhwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.1
    • /
    • pp.10-19
    • /
    • 2018
  • In this paper, a new high-frequency equivalent circuit model of printed spiral coils (PSCs) for radio-frequency interference (RFI) measurement has been proposed. To achieve high-frequency modeling, the proposed model consists of distributed components designed based on the design parameters of the PSCs. In addition, an analytic model for PSCs based on T-pi conversion has been proposed. To investigate the feasibility of the proposed model for RFI measurement, the transfer function between a microstrip line and a PSC has been extracted by combining the proposed model and mutual inductance. The self-impedances of the proposed model and the transfer function have been successfully validated using three-dimensional field simulation and measurements, revealing noticeable correlations up to a frequency of 6 GHz. The proposed model can be employed for high-frequency probe design and RFI noise estimation in the gigahertz range wireless communication bands.

Compact 40 GHz Hairpin Band-Pass Filter (초소형 40 GHz Hairpin 대역통과 여파기)

  • Lee, Young Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.1
    • /
    • pp.27-30
    • /
    • 2018
  • In this study, a 40 GHz band pass filter(BPF) employing a hair-pin structure has been designed, fabricated, and characterized for millimeter-wave wireless communication applications. Using the 3 dimensional(3-D) electromagnetic(EM) tool and design equations of the hairpin BPF, the BPF was desgned on the 5 mil-thick Duroid substrate(RT5880) with a relative dielectric constant (${\varepsilon}_r$) of 2.2. The tapping point (t) of the U-shape resonator in the input and output port has been determined using extracted an external Q-factor ($Q_e$). The coupling coefficients between the other resonators are calculated by adjusting the physical dimensions for the desired response of the BPF. The fabricated BPF was characterized using probing method on a probe station. Its measured center frequency(fc) and fractional BW are 41.6 GHz and 7.43 %, respectively. The measured return loss is below -10 dB at the pass band and the insertion loss is 3.87 dB. The fabricated BPF is as small as $9.1{\times}2.8mm^2$.

Characterization of growth hormone-like sequence of loach, Misgurnus mizolepis (미꾸라지 성장 호르몬 염기 서열의 특성에 대하여)

  • Kim, Jin-Kyung;Song, Young-Hwan
    • Journal of fish pathology
    • /
    • v.7 no.2
    • /
    • pp.95-103
    • /
    • 1994
  • We have prepared cDNA libray of loach. M. mizolepis in order to isolate cDNA clone of growth hormone gene. Total RNA was isolated from pituitary of loach, and then mRNA was further purified from total RNA by oligo (dT)-coupled magnetic beads. The purified mRNA was used as substrates to prepare cDNA. The resulting cDNA was ligated into the EcoRV/Smal site of pBlueKS+. The ligation mixture have transformed E. coli JM109 strain with electroporator to obtain high yield of transformation efficiency. All the transformants was screened with DIG-labeled Tilapia growth hormone gene by high density colony hybridization. After isolating 10 putative colonies showing the positive signals, secondary colony hybridization and southern hybridization could confirm it as true clones. The nucleotide sequence of one candidate, pCGHI, was compared with 312 bp DNA fragment used as DNA probe and show 52% relative homology to Tilapia growth hormone gene.

  • PDF