• 제목/요약/키워드: System-on-Glass

검색결과 1,534건 처리시간 0.032초

Effect of Additives on Transmittance of Tick Film Prints in PDP

  • Jun, Jae-Sam;Cha, Myung-Ryoung;Kim, Yu-Jin;Kim, Hyung-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.544-547
    • /
    • 2004
  • Glass frits for dielectric layers are mostly used for screen printing process. Several additives have already been known to be well matched with lead-oxide glasses system. The use of lead oxide, however, creates environmental problems, so many recent studies on lead-free glasses compositions have been carried out. A study of the suitability between additives and lead-free glass system is needed. In this study, we have used a screen-printing method to make thick films of lead-oxide glass and lead-free glass using different additives, and analyzed and compared the transmittance of the thick films.

  • PDF

FPD GLASS Carrier를 위한 자동 검사 시스템에 관한 연구 (A Study on the Automatic Inspection System for Flat Panel Display GLASS Carrier)

  • 김효남
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2014년도 제49차 동계학술대회논문집 22권1호
    • /
    • pp.399-400
    • /
    • 2014
  • 최근에 디스플레이 산업이 변화하고 우리나라 기업들이 세계시장을 주도해나가고 있는 실정이다. 특히 FPD 기술에 있어서 화면의 크기가 급속하게 대형화함에 따라 품질향상과 생산성 향상을 위해서 생상환경과 설비의 자동화가 매우 중요한 이슈가 되고 있다. 본 논문에서는 FPD 제조 공정 중 화학 증착 및 메탈 주입 공정 중 원판 GLASS의 이송 및 고정에 있어 항시 사용하는 GLASS CARRIER의 검사에 있어서 자동으로 검사할 수 있는 시스템을 제안한다.

  • PDF

인공 치아용 결정화 유리의 제조(II) - 생체적합성 (Fabrication of Glass Ceramics for Dental Artificial Tooth(II) -Biocompatibility-)

  • 유기수;한복섭
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권3호
    • /
    • pp.257-264
    • /
    • 1993
  • A study on the biocompatibility of two types of new glass-ceramics materials, metal disc and dental porcelain that were already made for dental artificial tooth in the previous study, have been attempted. The chemical behavior and the Victor's hardness change in she artificial saliva and Ringer's solution have been also investigated. From the experiment of Implantation of glass-ceramics Into dorsal subcutaneous tissue of Sprague-Dawley rats, glass-cerarmics did not show any particular system of rejection for histrocompatibility.

  • PDF

RPCVD system을 이용한 ${\mu}c$-Si:H의 저온 직접 성장 연구 (The study of direct ${\mu}c$-Si:H film growth using RPCVD system in low temperature)

  • 안병재;김도영;임동건;이준신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1818-1820
    • /
    • 1999
  • This paper presents direct ${\mu}c$-Si:H thin film growth on the glass substrates using RPCVD system (remote plasma chemical vapor deposition) in low temperature. Hydrogenated micro-crystalline silicon deposited by RPCVD system in low temperature is very useful material for photovoltaic devices, sensor applications, and TFTs (thin film transistors). Varying the deposition conditions such as substrate temperature, gas flow rate, reactive gas ratio $(SiH_4/H_2)$, total chamber pressure, and rf power, we deposited ${\mu}c$-Si:H thin films on the glass substrates (Corning glass 1737). And then we measured the structural and electrical properties of the films.

  • PDF

Zirconia-Glass frit 조성에서 MgO 및 착색료가 소결체의 색상 변화에 미치는 영향 (Effect of MgO and coloring agents on the coloring in zirconia-glass frit system)

  • 권은자;최에스더;이규선;이채현
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2150-2156
    • /
    • 2009
  • 지르코니아($3Y-ZrO_2$)에 frit을 첨가하고 MgO를 조제로 첨가하거나 혹은 하소된 성형체에 액상의 착색료에 침지하는 방법을 통하여 착색하고 얻어진 소결체의 물성과 색상 변화를 고찰하였다. Frit가 20 wt% 첨가된 지르코니아-frit조성에 MgO가 첨가됨에 따른 색상의 변화는 소결온도가 높아짐에 따라 구별가능한 정도로 효과가 있음을 확인하였다. 이 때 색상의 변화 정도는 MgO의 첨가량 변화에 의한 효과 보다는 소결 온도의 변화에 의한 효과가 더 크게 나타났음을 확인할 수 있었다. 액상의 착색료에 침지한 후 소결한 경우에서는 frit의 첨가량이 증가함에 따라 반사도가 증가하는 것으로 나타났으며 착색료에 침지하지 않은 경우에 비하여 색상의 변화가 감소함을 알 수 있었고 frit은 색상의 변화를 억제하는 것으로 나타났다.

Prediction of seismic cracking capacity of glazing systems

  • O'Brien, William C. Jr.;Memari, Ali M.;Eeri, M.
    • Earthquakes and Structures
    • /
    • 제8권1호
    • /
    • pp.101-132
    • /
    • 2015
  • This research formulates a closed-form equation to predict a glass panel cracking failure drift for several curtain wall and storefront systems. An evaluation of the ASCE 7-10 equation for Dclear, which is the drift corresponding to glass-to-frame contact, shows that the kinematic modeling assumed for formulation of the equation is sound. The equation proposed in this paper builds on the ASCE equation and offers a revision of that equation to predict drift corresponding to cracking failure by considering glazing characteristics such as glass type, glass panel configuration, and system type. The formulation of the proposed equation and corresponding analyses with the ASCE equation is based on compiled experimental data of twenty-two different glass systems configurations tested over the past decade. A final comparative analysis between the ASCE equation and the proposed equation shows that the latter can predict the drift corresponding to glass cracking failure more accurately.

GRC 제조용 내알칼리성 지르코니아계 고분자 겔섬유에 관한 연구 (Study on the Polymer Gel Fiber of Alkali Resistance Zirconia System for GRC)

  • 신대용;한상목;김경남;강위수
    • 한국세라믹학회지
    • /
    • 제31권8호
    • /
    • pp.934-940
    • /
    • 1994
  • Fibers of ZrO2-SiO2 system were prepared from the hydrolysis and condensation of Si(OC2H5)4 and Zr(OnC3H7)4 with different H2O/alkoxide molar ratios. It was found that fibers could be drawn in the viscosity range of 1~100 poise from HCl catalyzed solutions with lower water contents of the mole ratio H2O/alkoxide, r 2. The fibrous gels were converted into the corresponding oxide glass fibers by heating at 80$0^{\circ}C$. Mechanical test was performed on E, A and 20ZrO2-80SiO2 glass fibers reinforced cement in order to investigate the flexural strength. The flexural strength value of 20ZrO2-80SiO2 glass fibers reinforced cement was greater than those of E and A. The chemical durability of the fibers in alkaline solutions increased with ZrO2 content. The weight loss due to the corrosion by 2N-NaOH solutions at $25^{\circ}C$ for 160 hours was about 0.31$\times$10-2 mg/dm2 for the 20ZrO2-80SiO2 glass fibers, which was superior to that of Vycor glass.

  • PDF

$TiO_2$ 함유 고굴절솔 유리의 착색에 관한 연구 (Study on the Color of High Index Glass Containing $TiO_2$)

  • 김병훈
    • 한국세라믹학회지
    • /
    • 제17권4호
    • /
    • pp.203-207
    • /
    • 1980
  • The optical absorption of high index glasses of the system TiO2-BaO-B2O3 prepared from the raw materials for an optical waveguide glass has been measured in the near ultraviolet region. The amount of Ti3+ in the glass could be reduced to a level less than 5 ppm by melting a batch added with pure nitric acid, using a fused quartz crucible in an oxygen gas atmosphere. The ultra-pure glass of 10mm thick prepared in such a way did not show any appreciable color even for the one containing 30 mol% TiO2 and having refractive index nD of 1.84 and Abbe's number vD of 28.8. The wavelength of ultraviolet absorptin edge was longer for the glass of higher index and higher dispersdion. The melting of a TiO2 containing glass in a platinum crucible resulted in a coloration of the glass due to the dissolved plutinum from the crucible, which was more intense for the one containing larger amount of TiO2.

  • PDF

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF

Effect of Boron Additions on Glass Formation and Magnetic Properties of Fe-Co-Ti-Zr-B Amorphous Ribbons

  • Kim, Sumin;Han, Bo Kyeong;Choi-Yim, Haein
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.164-167
    • /
    • 2016
  • The effect of the B additions on glass formation and magnetic properties is reported for the $Fe_{(87-x-y)}Co_yTi_7Zr_6B_x$ (x = 2, 4, 6 and y = 35, 40) alloy system. The ribbon samples with the width of 2 mm for each composition were prepared by the melt spinning technique; furthermore, their phase information was obtained from X-ray diffraction. Glass formation and magnetic properties were measured using differential scanning calorimetry and vibrating sample magnetometer respectively. The $Fe_{45}Co_{40}Ti_7Zr_6B_2$ (x = 2 and y = 40) system has the nanocrystalline phase identified as ${\alpha}-Fe$, as well as the amorphous phase, whereas all other alloys are fully amorphous. It is associated with the role of B on the glass formation. The widest supercooled liquid region is obtained as 71 K at x = 4 (both y = 35 and 40). The saturation magnetization decreases with the increase of the amount of the B addition, and the highest value is 1.59 T as x = 2 and y = 35 for this alloy system.