• Title/Summary/Keyword: System temperature

Search Result 17,701, Processing Time 0.04 seconds

Temperature Monitoring System of Power MOSFET for IPCM (지능형 전력제어모듈을 위한 온도 모니터링 시스템)

  • Choi Nak-Gwon;Kim Ki-Hyun;Kim Hyoung-Woo;Seo Kil-Soo;Kim Nam-Kun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • We suggest a novel temperature detection method utilized in temperature monitoring system. Suggested method detects temperature variation by using $R_{ds(on)}$ characteristics of MOSFET, while conventional methods are using extra devices such as a temperature sensor or an over-temperature detection transistor. For voltage detection between drain and source, 10 bits resolution ADC is needed. Therefore possible measurement signal range is about ten mV. If detected temperature's voltage exceed protection temperature's voltage then controller generates OT (Over Temperature) signal to stop MOSFET's trigger signal. Whole process of measurement is controlled by software. Experimental results show that the developed temperature monitoring system can provide the suitable temperature monitoring method and difference between detected and data sheet value of the suggested system is about $3\%$.

Development of an Automatic Body Temperature Measuring System for Dairy Cattle (젖소의 자동 체온 측정 시스템 개발)

  • 정길도;김형주;김용준;한병성;김명순
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.140-143
    • /
    • 1996
  • In this paper the development of an automatic body temperature measuring system which can be attached to the milking machine has been studied. Since the disease is highly related to the body temperature of the cattle, early detection of the abnormal temperature would prevent the severe problems which may occur in dairy farms. The electronic component AD590 is used as a temperature sensor for the system. The device is highly robust against the noise since the output signal is the current. So it can be applied to the long distance sensing. The resolution of the signal is $0.1{\circ}C$ and the current is 10 mV. Also the A/D converter is designed for interfacing the sensor with a computer. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of the dairy cattle properly.

  • PDF

Heat transfer of green timber wall panels (그린팀버월 패널의 열전달 특성)

  • Kim, Yun-Hui;Jang, Sang-Sik;Shin, Il-Joong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.1
    • /
    • pp.115-120
    • /
    • 2011
  • 20% of total energy use to sustain temperature of building inside. In this reasons, researchers effort to improve the thermal insulation capacity with new wall system. Using appropriate materials and consisting new wall system should considered in energy saving design. OSB(Oriented strand board), Larch lining board used to consist wall system. $2{\sim}6$ Larch lining board has tongue & groove shape for preventing moisture. Comparing with gypsum board and green timber lining board as interior sheathing material, temperature difference of Green timber wall system was bigger than temperature difference of gypsum board wall system. This aspects indicate that Green timber wall system was revealed higher thermal insulation property than gypsum board wall system. Gypsum board portion transfer heat easily because temperature difference gradient of gypsum board wall system was smaller than OSB wall system. Total temperature variation shape of G-4-S and G-6-S show similar model but, temperature variation shape in green timber wall portion assume a new aspect. The purpose of this study was that possibility of thermal insulation variation and new composition of wall system identify to improve thermal insulation performance. In the temperature case, this study shows possibility of improving thermal insulation performance. Humidity, sunshine and wind etc. should considered to determine building adiabatic properties.

Thermal Performance of Solar Thermal System by On-Off Differential Temperature of Differential Temperature Controller (차온제어기의 On-Off 온도설정에 따른 태양열 시스템 열성능)

  • Shin, U-Cheul;Baek, Nam-Choon
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • On-off differential controller is one of the very important components which affect the system performance of the active solar thermal system. In this study, analyses were made regarding the influence of "on-off" setting temperature on the system efficiency and on the electrical consumption by circulation pump. This study was performed by experiment as well as the computer simulation using TRNSYS program. The simulation system was developed in this study was verified the its reliability by the experimental results. As a results, the turn off temperature(${\Delta}T_{off}$) is much more influence than the turn on temperature(${\Delta}T_{on}$) on the system efficiency. It is more clear and sensitivity in winter season. Finally the optimum on-off setting value and the system on-off pattern according to the several different kind of system was also represented.

Measuring System for Evaluating Sensing Reliability of Infrared Temperature Sensors

  • 박준혁;이민철;부광석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.169-173
    • /
    • 1997
  • In this paper, auto measuring system for evaluating sensing reliability of infrared temperature sensors is developed. A developed system is composed of temperature controller, measuring sysytem and operating S/W. A constant temperature control of a chamber is accomplished by multi-heater using PI control. It is shown that the control resulte of temperature are well followed to the desired temperature value. The developed untegrated measuring system will increase reliability and productivity of products.

Measurement of Engine Piston Temperature Distribution by Using Scissors-type Linkage System (가위형 링크 기구를 이용한 기관의 피스톤 온도 분포 측정)

  • 김재업;이종화;김세웅;김응서
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.69-76
    • /
    • 1993
  • The program for the development of linkage system was made and the scissors-type linkage system was designed. The piston temperature distribution under steady state was measured by the linkage system and thermocouple. The effects of engine speed, coolant outlet temperature, and torque on the piston temperature were investigated.

  • PDF

Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer (틸팅열차 주변압기 냉각시스템의 온도설정알고리즘)

  • Han, Do-Young;Noh, Hee-Jeon;Won, Jae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

The Study of Pressurant Inflow Prediction Using Temperature Change of Geostationary Satellite Propellant System (정지궤도 인공위성 추진시스템의 온도변화를 통한 배관내 가압제 유입 예측기법 연구)

  • Park Eung Sik;Jun Hyoung Yoll;Park Bong Kyu;Han Cho Young;Choi Seong Bong;Kim Yong Min
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.96-99
    • /
    • 2005
  • The geostationary satellite propulsion system has thermistors which can measure liquid propellant temperature at tanks, pipes and etc. In the satellite propulsion system with several tanks, the propellant in the tanks is moved by temperature change and this temperature pattern is constant. In this paper, the temperature change pattern of KOREASAT 1 propulsion system is compared and the prediction study of pressurant inflow using temperature change of geostationary satellite propulsion system is described.

  • PDF

Performance Analysis of Cascade Refrigeration System with Respect to Refrigerants Appling to High Temperature Cycle (고온측 냉매에 따른 이원 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.45-50
    • /
    • 2017
  • This paper presents the Coefficient of performance(COP) and mass flow ratio of cascade refrigeration system with respect to refrigerants appling to high temperature cycle. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporating temperature, condensing temperature and internal heat exchanger effectiveness in high temperature cycle. The result of this study is as follows : The COP of cascade system increases with increasing degree of superheating and subcooling, compressor efficiency and internal heat exchanger effectiveness except increasing condensing temperature. The mass flow ratio of low and high temperature cycle increases with increasing evaporating temperature and condensing temperature, but decreases with increasing internal heat exchanger effectiveness, degree of superheating and subcooling. Also, the mass flow ratio has no correlation with compressor efficiency at high temperature cycle.

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.