• Title/Summary/Keyword: System of Circulation

Search Result 1,689, Processing Time 0.031 seconds

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

The Analysis for Flow Circulation System in HANARO Flow Simulation Facility (하나로 유동 모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.

System Analysis for the Automated Circulation (대출업무 자동화를 위한 시스팀설계에 관한 연구)

  • Kim, Kwang-Yeong
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.4 no.1
    • /
    • pp.85-102
    • /
    • 1980
  • Accepting the necessity for maintaining the objectives of the existing circulation system, the computer-based system could be designed by the system analyst and librarians to gain a variety of improvements in the maintenance, accessibility of circulation records and more meaningful statistical records. If the terminal can be operated on-line, then this circulation data is transmitted directly to the computer, where it may update to the circulation file immediately or alternatively be kept in direct access file for updating in batch mode. on-line system in the circulation operations is "data-collection system" and "Bar-coded label system" Bar-coded label system is simple, quick, and error-free input of data. Attached to CRT terminal is a "light pen" which is hand held and will read a bar-coded label as the pen is passed over the labels (one affixed to the book itself, other carried on the borrower cards). Instantaneously the data concerning transaction is stored in the central mini-computer. It is useful, economical for us to co-operate many libraries in Korea and design borrower's ID code, book no., classification code in the Bar-coded label system by the members of the computer center and the library staff at every stage. As for book loan, the borrowers ID code, book number and classification code are scanned by the bar-code scanner or light pen and the computer decides whether to loan and store the data. The visual display unit shows the present status of a borrowers borrowing and decides whether borrower can borrow.

  • PDF

Response Analysis of the Coronary Circulation Under the T-PLS Operation via a Lumped System Model (집중시스템 모델을 이용한 이중박동 생명보조장치 작동하의 관상순환계 반응해석)

  • Ko, Hyung-Jong;Park, Jong-Cheon;Shim, Eun-Bo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • In this paper, a computational analysis using a lumped system model is performed to investigate the hemodynamics of coronary circulation under the operation of T-PLS relevant to the cardiac arrest cases. The coronary circulation system is assumed to be comprised of three compartments: coronary arteries, coronary capillaries, and coronary veins. The effect of myocardial muscle contraction or relaxation is represented by temporal variations in the bias pressure. To verify the present method, we analyzed the coronary circulation for normal case and then compared the results with the existing data. Numerical results on the cardiac arrest model showed that T-PLS can increase LAD flow significantly.

  • PDF

The Effect of Flow Induction Machine in Water Circulation System of Cheongna Canal Way (청라지구 물순환체계내 주운수로의 흐름유발시설 설치효과)

  • Kim, Dong-Eon;Choi, Gye-Woon;Park, Young-Sik;Yoon, Geun-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.77-81
    • /
    • 2010
  • This study carried out hydraulic model test for water circulation system in Cheongna district as part of Incheon Free Economic Zone. Canal way project of Cheongna was planned to establish for environment-friendly water circulation system, improve quality of life and diversification of traffic through using boat as a water-friendly international business city. The navigation canal, There are two intake facility in central park and it can purify water 15,000$m^3$ per day. After purify, water move to 8 facility of water culture area which supplies water in canal way. This process called water circulation system in cheongna. Also, there are several flow induction machine in canal way except south-north way. Therefore, this study will verify about validity of water circulation system's safety through hydraulic model test.

  • PDF

Analysis of the Flow Rate for a Natural Cryogenic Circulation Loop during Acceleration and Low-gravity Section (극저온 자연순환회로의 가속 및 저중력 구간 유량 분석)

  • Baek, Seungwhan;Jung, Youngsuk;Cho, Kiejoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.5
    • /
    • pp.43-52
    • /
    • 2019
  • Cryogenic propellant rockets utilize a natural circulation loop of cryogenic fluid to cool the engine inlet temperature before launch. The geometric information about the circulation system, such as length and diameter of the pipes and the heat input to the system, defines the mass flow rate of the natural circulation loop. We performed experiments to verify the natural circulation mass flow rate and compared the results with the analytical results. The comparison of the mass flow rate between experiments and numerical simulations showed a 12% offset. We also included a prediction of the natural circulation flow rate in the low-gravity section and in the acceleration section in the upper stage of the launch vehicle. The oxygen tank should have 100 kPa(a) of pressure in the acceleration section to maintain a high flow rate for the natural circulation loop. In the low-gravity section, there should be an optimal tank pressure that leads to the maximum natural circulation flow rate.

A Study on the Circulation System on accordance with the Merchandise in Discount Store - with reference to the spatial configuration and the VMD pattern - (대형아트의 상품구성에 따른 동선체계의 특징에 관한 연구 - 공간구조와 공간연출의 특성을 기준으로 -)

  • Kim, Sae-Eun;Moon, Jung-Mook
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.6
    • /
    • pp.137-142
    • /
    • 2008
  • Since mid 1990s, the domestic market in Korea has been changing drastically especially in the field of discount stores. The competition among this market is more severe and the consuming pattern is also changed. This study is to examine the correlation between the customer's circulation and the spatial configuration by using Space Syntax and VMD pattern through the MD plan of each floor in Discount store. Throughout this study, it tries to find out the Quantitative analysis among three factors - the customer's circulation, spatial configuration and VMD investigation. The pattern of customer's circulation appears differently according to the identity of customer and store layout, but with the result, customer's circulation system is in accordance with the floor layout in the store. In result of the study, the circulation of the customer was found to have a close relationship with spatial structure that is composed by the MD pattern in a discount store in the area of food section. Also, the circulation system in the rest area except food section is more affected by the VMD pattern rather than spatial structure.

Post Test Analysis to Natural Circulation Experiment on the BETHSY Facility Using the MARS 1.4 Code

  • Chung, Young-Jong;Kim, Hee-Cheol;Chang, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.638-651
    • /
    • 2001
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic code, MARS 1.4, for the analysis of thermal-hydraulic behavior in PWRs during natural circulation conditions. The code simulates a natural circulation test, BETHSY test 4. la, which was conducted on the integral test facility of BETHSY. The test represented the cooling states of the primary cooling system under single-phase natural circulation, two-phase natural circulation and the reflux condensation mode with conditions corresponding to the residual power, 2% of the rated core power value and 6.8 MPa at the secondary system. Based on MARS 1.4 calculations, the major thermal-hydraulic behaviors during natural circulation are evaluated and the differences between the experimental data and calculated results are identified. The calculated results show generally good behavior with regard to the experimental results; the region of single-phase natural circulation is 100-92% of the initial mass inventory, two-phase natural circulation is 84-63 %, and the reflux condensation mode occurred below 58 %. U-tubes empty and the core uncovery are obtained at 39 % and 34 % of the initial mass inventory, respectively.

  • PDF

An Experimental Study on the Flow Characteristics Inside an Open Two-Phase Natural Circulation Loop (개방된 2상 자연순환 회로내의 유동특성에 관한 실험적 연구)

  • 경익수;이상용
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.5
    • /
    • pp.1313-1320
    • /
    • 1993
  • Flow patterns inside the riser section and the effects of the heater inlet-and exit-restrictions, liquid charging level and the heater inlet subcooling on the flow characteristics inside an open two-phase natural circulation loop were studied experimentally. Three basic circulation modes were observed ; periodic circulation (A)(flow oscillations with incubation(no boiling) period), continuous circulations(stable operation mode with no flow oscillations), and periodic circulation (B) (flow oscillations with continuous boiling). The circulation rate increases and then decreases with the increase of the heating rate and the maximum circulation rate appears with the continuous circulation mode. The decrease of the inlet-restriction or the increase of the exitrestriction destabilizes the system. When the liquid charging level or the inlet subcooling decreases, the continuous circulation mode starts at the lower heating rate and the system is stabilized.

The Pedestrian Integrated Circulation System in Mixed-use Building based on User Behavior (이용자 행태 기반 복합건축 보행자 통합동선계획)

  • Lee, Jin-Kyoung;Kim, Chan-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.12
    • /
    • pp.21-29
    • /
    • 2019
  • The purpose of the study is to be the pedestrian integrated circulation system of malling route and the third route in Mixed-use Building based on User Behavior. The study has performed by the following approaches: Initially, literature reviews are performed related to a pedestrian route by user in mixed-use building. Second, general and stroller users moving route are analyzed based on the outcome of the case study. Finally, the study develops the efficient pedestrian integrated circulation system of malling route and the third route in Mixed-use Building. According to the study, the following conclusions were made: First, An integrated plan for escalators and EVs, which are accessible to both users and strollers, is needed. Second, The entrance automatic door and circulation elements should be connected for continuous move by the stroller users. Finally, The circulation system of complex buildings should be a simple spatial structure and route plan that users can easily recognize.