• Title/Summary/Keyword: System failures

Search Result 1,131, Processing Time 0.035 seconds

Seismic Performance of Precast Beam-Column Joints with Thru-Connectors (관통형 연결재로 연결된 PC 보-기둥 맞댐 접합의 내진성능에 관한 실험적 연구)

  • Park, Soon-Kyu;Kim, Min-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.441-450
    • /
    • 2010
  • This is a preliminary study on the development of precast beam-column joints for dry construction methodology. Precast beam column joints with thru-connectors (BCJ_TC) using high strength bars or PS strands were developed and their seismic performance including strength degradation, stiffness degradation and energy dissipation capacity was experimentally evaluated. Test results showed that compressive failures at the end blocks of PC beam members occurred dominantly while PC columns including panel zones were free from any damage. However, the connections confined with CFRP at the end block showed much improved seismic performance than that of the unconfined connections. Connections with neoprene pad fillers between beam and column interfaces were better than the other connections in all the seismic performances except initial stiffness. To improve the seismic performances of BCJ_TC, compressive strength of the concrete at the end block need to be increased to compensate for the additional compressive stresses due to unbonded connectors and deformation of connectors should be controlled respectively.

Failure Mechanism of Geosynthetic Reinforced Segmental Retaining Well in Tiered Configuration Using Reduced-scale Model Tests (축소 모형 실험에 의한 계단식 보강토옹벽의 파괴 메카니즘)

  • Yoo Chung-Sik;Jung Hyuk-Sang;Jeon Sang-Soo;Lee Bong-Won;Kim Ki-Yeon;Jeon Han-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.3
    • /
    • pp.65-77
    • /
    • 2005
  • This paper investigates the failure mechanism of geosynthetic-reinforced segmental retaining walls with tiered configuration using reduced-scale model tests. The reduced scale model test set-up was established to simulate a 5 m high full-scale wall. The geometry and material properties used in the model test were determined based on the Similitude Laws. The wall failures in the model tests were successfully generated by their self weight without any surface loading and analyzed examining the digital video recordings. The failure mechanisms was examined with respect to the various offsets between the lower and upper teres and the reinforcement length. Based on the results the appropriateness of the current design guideline was discussed.

Creep Characteristics Verification of FE Model for SnPb Solder (SnPb 솔더에 대한 유한요소모델의 크리프 특성 검증)

  • Han, Chang-Woon;Park, No-Chang;Oh, Chul-Min;Hong, Won-Sik;Song, Byeong-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • The heat sink system for a main board in a network server computer is built on printed circuit board by an anchor structure, mounted by eutectic SnPb solder. The solder creeping is caused by a constant high temperature condition in the computer and it eventually makes fatal failures. The FE model is used to calculate the stress and predict the life of soldered anchor in the computer. In the model, Anand constitutive equation is employed to simulate creep characteristics of solder. The creep test is conducted to verify and calibrate the solder model. A special jig is designed to mitigate the flexure of printed circuit board and to get the creep deformation of solder only in the test. Test results are compared with analysis and calibration is conducted on Anand model's constants. Precise life prediction of soldered anchor in creep condition can be performed by this model.

Accelerated Ultrasonic Fatigue Testing Applications and Research Trends (초음파 가속피로시험 적용 사례 및 연구 동향)

  • Cho, In-Sik;Shin, Choong-Shig;Kim, Jong-Yup;Jeon, Yong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.6
    • /
    • pp.707-712
    • /
    • 2012
  • Very high cycle fatigue (VHCF) behavior of aerospace components has emerged much attention due to their long service life. In this study, a piezoelectric ultrasonic fatigue testing (UFT) system has been developed by Mbrosiatec Co., Ltd. to study the high cycle fatigue (HCF) strength of Ti-6Al-4V alloy. Hourglass-shaped specimens have been investigated in the range from $10^6$ to $10^9$ cycles at room temperature under completely reversed R = -1 loading conditions,. Scanning electron microscopy (SEM) analysis revealed that failures occurred in the entire range up to the gigacycle regime, and the fractures have beenfound to be initiated from the surface, unlike in steels. However, it was found from the SEM microgprahs that microcracks transformed into intergranular fractures. Thus, it can be concluded from according to the results that this test method can be applicable to commercialized automotive and railroad parts that require high cycle fatigue strength.

Performance Analysis on Coexistence of Contention-based Heterogeneous Wireless Networks (경쟁기반 이기종 무선 통신망의 공존 성능 분석)

  • Park, Eun-Chan;Rim, Min-Joong
    • Journal of Internet Computing and Services
    • /
    • v.12 no.4
    • /
    • pp.1-14
    • /
    • 2011
  • This paper analyzes the fairness and efficiency of channel sharing when heterogeneous wireless networks that have different transmission power and/or coverage coexist with the contention-based channel access protocol. First, we show that the existing CSMA (carrier sensing multiple access) protocol, that is a prevailing contention-based mechanism, results in significant unfairness of channel access because of (1) the asymmetric capability of carrier sensing and (2) the blindness of binary exponential backoff and link adaptation mechanisms to the interference-driven transmission failures. Next, we derive the feasible region of carrier sensing thresholds that assures spatial reuse and fair channel sharing simultaneously. Moreover, we establish an analytical model for per-system throughput and investigate the effect of contention window size and transmission rate on the fairness and efficiency of channel sharing. Finally, we compare the performance of several approaches for fair channel sharing via simulations under various network configurations.

Lessons from the Design of Innovation Systems for Rural Industrial Clusters in India

  • Abrol, Dinesh
    • Journal of Technology Innovation
    • /
    • v.12 no.2
    • /
    • pp.67-97
    • /
    • 2004
  • Practical experience with technology implementation of the upgrading of very small village industries in India suggests that innovation failures are not merely a result of the lack of proper interaction between the users and suppliers of technologies under implementation, but also a result of adoption of the primitive conception of competitiveness in their practice of technology development. The approach of promoting the small producers to become individually competitive by using labour intensive, small-scale intermediate technologies is proving to be totally inadequate for the achievement of technological efficiency in a dynamic sense. Guided by a primitive notion of competitiveness, the suppliers of intermediated technologies are thus being led into limiting their technological efforts in the sectors of direct interest to the rural industrial clusters to the transitional objectives of mainly poverty alleviation. Consequently they have not been able to target the small producers of these village industries for the objectives of business growth. This paper posits that under competitive conditions the self-employed small producer has not only to come together for access to resources, but also has to emerge as a multi-sectoral collective of producers, co-operating in production. With the aim to draw lessons that are generic and have policy implications for the development of innovation systems for local economy based rural industrial clusters and value chains, the author analyses in this paper the experience of innovation in technological systems for the sectors of leather, fruits and vegetable processing and agro processing by the People's Science Movement with the help of the Ministry of Science and Technology and other sectoral ministries in India where rural poor were required to pool the resources and capabilities for raising the scale and scope of their collective production organization.

  • PDF

A Study on Sensitivity Analysis and Uncertainty Analysis for Continuous Stirred Tank Reactors (연속교반탱크 반응기에 대한 민감도 및 불확실성 분석에 관한 연구)

  • Kim In-Won;Jin Sang-Hwa;Kim In-Tea;Song Hee-Oeul;Yeo Yeong-Koo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.70-78
    • /
    • 2001
  • In order to find out which equipment failures were mostly contributed to the rupture of a continuous stirred tank reactor, the sensitivity analysis was carried out. The uncertainty of likelihood of the rupture of reactor was studied by the uncertainty analysis. And the cost effectiveness analysis resulted in the recommendation of the exchange with a better reliable unit if you want to maintain the process efficiently from the view point of cost. The uncertainty analysis showed that the likelihood of catastrophic rupture of the reactor was distributed from $8.09{\times}10^{-04}$ to $5.50{\times}10^{-02}/year$. As a result of cost-effectiveness analysis, it was proposed to exchange the voting logic unit for a better safer system.

  • PDF

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Clinical and Neuroimaging Outcomes of Surgically Treated Intracranial Cysts in 110 Children

  • Lee, Eun-Jung;Ra, Young-Shin
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.325-333
    • /
    • 2012
  • Objective : The indications and optimal surgical treatments for intracranial cysts are controversial. In the present study, we describe long-term clinical and neuroimaging results of surgically treated intracranial cysts in children. The goal of this study is to contribute to the discussion of the debate. Methods : This study included 110 pediatric patients that underwent surgeries to treat intracranial cysts. Endoscopic cyst fenestrations were performed in 71 cases, while craniotomies and cyst excisions (with or without fenestrations) were performed in 30 patients. Cystoperitoneal shunts were necessary for nine patients. Long-term results were retrospectively assessed with medical and neuroimaging records. Results : Clinical and radiological improvement was reported in 87.3% and 92.8% of cases, respectively, after endoscopic neurosurgery, and in 93.3% and 100% using open microsurgery whereas 88.9% and 85.7% after shunt operation. There were no statistical differences in clinical outcomes (p=0.710) or volume reductions (p=0.177) among the different surgeries. There were no mortalities or permanent morbidities, but complications such as shunt malfunctions, infections, and subdural hematomas were observed in 56% of the patients that had shunt operations. A total of 13 patients (11.8%) underwent additional surgeries due to recurrences or treatment failures. The type of surgery performed did not influence the recurrence rate (p=0.662) or the failure rate (p=0.247). Conclusion : Endoscopic neurosurgeries are less invasive than microsurgeries and are at least as effective as open surgeries. Thus, given the advantages and complications of these surgical techniques, we suggest that endoscopic fenestration should be the first treatment attempted in children with intracranial cysts.

Surgical Outcomes and Complications after Occipito-Cervical Fusion Using the Screw-Rod System in Craniocervical Instability

  • Choi, Sung Ho;Lee, Sang Gu;Park, Chan Woo;Kim, Woo Kyung;Yoo, Chan Jong;Son, Seong
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.4
    • /
    • pp.223-227
    • /
    • 2013
  • Objective : Although there is no consensus on the ideal treatment of the craniocervical instability, biomechanical stabilization and bone fusion can be induced through occipito-cervical fusion (OCF). The authors conducted this study to evaluate efficacy of OCF, as well as to explore methods in reducing complications. Methods : A total of 16 cases with craniocervical instability underwent OCF since the year 2002. The mean age of the patients was 51.5 years with a mean follow-up period of 34.9 months. The subjects were compared using lateral X-ray taken before the operation, after the operation, and during last follow-up. The Nurick score was used to assess neurological function pre and postoperatively. Results : All patients showed improvements in myelopathic symptoms after the operation. The mean preoperative Nurick score was 3.1. At the end of follow-up after surgery, the mean Nurick score was 2.0. After surgery, most patients' posterior occipito-cervical angle entered the normal range as the pre operation angle decresed from 121 to 114 degree. There were three cases with complications, such as, vertebral artery injury, occipital screw failure and wound infection. In two cases with cerebral palsy, occipital screw failures occurred. But, reoperation was performed in one case. Conclusion : OCF is an effective method in treating craniocervical instability. However, the complication rate can be quite high when performing OCF in patients with cerebral palsy, rheumatoid arthritis. Much precaution should be taken when performing this procedure on high risk patients.