• 제목/요약/키워드: System Margin

검색결과 1,016건 처리시간 0.03초

모델 불확실성을 고려한 변형된 IMC-PID 제어기 설계 (A Modified IMC-PID Controller Design Considering Model Uncertainty)

  • 김창현;임동균;서병설
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.128-130
    • /
    • 2005
  • This paper proposes a modified IMC-PID controller that introduces controlling factor of the system identification to the standard IMC-PID controller in order to meet the design specifications such as gain, phase margin and maximum magnitude of sensitivity function in the frequency domain as well as the design specifications in time domain, settling, rising time and overshoot, and so on.

  • PDF

입력 시간지연 시스템의 루우프 전달복구 설계 기법 (Loop transfer recovery design for input-delayed systems)

  • 박상현;이상정
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1201-1204
    • /
    • 1996
  • The previous results on LTR methods for time delay systems need the solution of the operator-type Riccati equation. In addition, it can be difficult to make the target loop shape representing the design specification. This paper proposes a new LTR method for input-delayed systems using well-established LTR method for non-delay systems. For doing this, a time delay margin is derived and the time delay of the input-delayed systems is assumed less than equal to the time delay margin. A simple example is presented for illustrations.

  • PDF

퍼지를 이용한 실시간 안정도 판별과 에너지 마진의 추정 (Real-time Stability Assessment and Energy Margin Estimation using Fuzzy)

  • 최원찬;김수남;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1239-1241
    • /
    • 1999
  • In this paper, we propose real time transient stability assessment and energy margin estimation using fuzzy approximate reasoning. The proposed method used rotor angle, kinetic energy and acceleration power of generators at clearing time as fuzzy input. In order to calculate energy margin in transient energy function (TEF), we obtained controlling unstable equilibrium point (UEP) using mode of disturbance procedure (MOD). The proposed algorithm is tested on 4-machine, 6-bus, 7-line power system to prove of effectiveness.

  • PDF

전압안정도여유를 고려한 무효전력원 배분계획 (The Optimal VAR Planning Considering Voltage Stability Margin)

  • 송길영;최상규;남국재용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.33-35
    • /
    • 1993
  • This paper presents a new optimal VAR planning algorithm considering voltage stability margin. The characteristic of this method is to make it possible to formulate VAR planning for the dual purpose of maintaining voltage profiles within specified limits, and increasing the voltage stability margin of anticipated operating conditions with respect to voltage collapse. The IEEE-30 bus system is used to demonstrate the capability of the proposed algorithm.

  • PDF

절전제어를 위한 사용자 감성마진 적용 능동규칙시스템 (Active Rule System Based on User's Emotional Margin for Power Saving Control)

  • 이연식;장민석;강선경
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.119-124
    • /
    • 2014
  • 본 논문은 절전제어를 위한 사용자 감성마진 적용 능동규칙시스템을 제안한다. 이는 공간의 조명 환경을 평가하여 사용자의 감성을 해치지 않는 범위 내에서 능동규칙을 사용하여 조도를 조절함으로써 절전을 유도하고자 하는 시스템의 일부이다. 이를 위하여, 조도 측정 및 분석 결과를 기반으로 세부적인 조도기준 범위와 사용자 감성마진 하한조도를 설정하고, 이러한 값들을 감성마진 적용 능동규칙 설계에 사용한다. 또한 이동 에이전트가 이주 대상 센서 노드들을 차례로 방문하여, 사용자 조건, 용도 및 필요에 따른 다양한 능동규칙을 통하여 센서 데이터를 수집 및 전송하며, 임의의 발생 사건들(센서 데이터 값 및 시간 등의 변화)에 상응하는 조치들을 직접 실행할 수 있는 이동에이전트를 이용한 능동규칙시스템을 설계 및 구현한다. 또한, 규칙베이스와 이동에이전트 센서 네트워크 미들웨어시스템과의 연동을 통하여 다양한 능동적 센서 네트워크 응용에의 적용 가능성을 보인다.

실시간 감시 정보를 이용한 전압안정도 제어 방안에 대한 연구 (A Study on the Voltage Stability Control Scheme using Real-time Monitoring Data)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.206-212
    • /
    • 2017
  • In this paper, using the power system information obtained from real-time monitoring device, to analyze the voltage stability margin index and described the voltage stability control scheme for voltage stability enhancement. Based on the utilization of the voltage stability monitoring index based on local information provided by the PMU(Phasor Measurement Unit), the purpose of the plan is to control the system stably in real time. In order to apply the load control scheme, the voltage stability margin is calculated using the data acquired through the PMU installed in each load bus. If the voltage drops below a certain level, load control is performed for each. The effectiveness of the voltage stability control measures is applied to the actual KEPCO system to analyze the effectiveness.

고등학교 교과용 도서 체제에 관한 학생들의 시 지각 반응 연구 (A Study of Student' Visual Perceptive Response to Reading System for High School Textbooks)

  • 이영호
    • 한국인쇄학회지
    • /
    • 제12권1호
    • /
    • pp.99-115
    • /
    • 1994
  • This styudy analyzed the main bodies, marginal space, Position of the main bodies of curent textbooks in high schools and "the eriteria of reading system for textbooks" which was sugested the Department of Education and Provided some sugestions for the improvement. The research methods used for the study were both literature review and survey rdsdarch with a questionaire. Inorder to research for the main body of textbook, space of margin, the optimum position fo the main body, sizes of litters, spaces between letters, words, lines length of lines, sizes of main body and margin, and margin, and postitionof main body were checked through a related literature review. For the questionaire experiment, a questionaire based on data drawn from analysis of textbooks, "criteria for reading system of textbook" sugested by the Department of Education, and some suggestions for improvement by the researcher was made and used for the test, targetting 384 body and girl students in high schools.

  • PDF

과도안정도 에너지 마진 향상을 위한 TCSC 적정치의 실시간 산정 (Real-Time Estimation of TCSC Quantity for Improvement of Transient Stability Energy Margin)

  • 김수남;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.242-244
    • /
    • 2000
  • This paper presents a method for real-time estimation of TCSC quantity in order to enhance the power system transient stability energy margin using fuzzy neural network in multi-machine system. This paper has two parts, the first part is to estimate the energy margin. To set critical energy, we use the potential energy boundary surface(PEBS) method which one of the transient energy function(TEF) method. And the second is to determine the TCSC quantify and the line to be injected. In order to make training data in this step, we use genetic algorithm. The proposed method is applied to 6-bus, 7-line, 4-machine model system to show its effectiveness.

  • PDF

광역정전 예방을 위한 분산형 부하 제어 방안에 대한 연구 (A Study on Decentralized under Voltage Load Shedding Scheme for Preventing Wide-area Black Out)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.1-6
    • /
    • 2014
  • An electric power system sometimes fails because of disturbances that occur unexpectedly, such as the uncontrolled loss of load that developed from cascading blackout. Which make stability through a little of under voltage load shedding should work. The development of phasor measurement unit(PMU) makes network supervision possible. The information obtained from PMU is synchronized by global positioning system(GPS). There are many real-time algorithms which are monitoring the voltage stability. This paper presents the study on the VILS(Voltage Instability Load Shedding) using PMU data. This algorithm computes Voltage Stability Margin Index(VSMI) continuously to track the voltage stability margin at local bus level. The VSMI is expressed as active and reactive power. The VSMI is used as an criterion for load shedding. In order to examine the algorithm is effective, applied to KEPCO system.

The Actuator for High-Speed CD/DVD Rewritable System

  • Song, Byung-Youn;Jang, Dae-Jong;Nam, Do-Sun;Shin, Kyung-Sik;Seong, Pyong-Yong;Lee, Ju-Hyung
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.378-380
    • /
    • 2002
  • There has been lower the tilt margin by the increase of coma aberration due to the reduction of wave-length and the increase of numerical aperture for high density recording. The RF signal degradation is increased as the decrease of tilt margin. To compensate the tilt margin, the optical pick-up actuator for high-speed CD/DVD re-writable system should be able to drive the radial-tilt motion. We announce that the 3-axis drive actuator for high-speed CD/DVD rewritable system. And what was more, the DC/AC sensitivities of this actuator are suitable fur the low-speed playability, the high-speed readability and the high-speed rewritability.

  • PDF