• Title/Summary/Keyword: System Loss Factor

Search Result 594, Processing Time 0.031 seconds

A Status Analysis on the Field Management of Professional Construction Firms after Abrogation of Construction Participants System (시공참여자제도 폐지 이후 전문건설업체의 현장관리 실태분석)

  • Park, Kyoung-Hun;Kim, Hwa-Joong;Son, Chang-Baek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.199-203
    • /
    • 2009
  • After the construction participants system is abolished, expectations are high for its consequences such as liquidating paper-companies, holding back low price contracts, and improving multi-stepwise subcontract structure. However, the professional construction firms have been took responsibilities and obligations as businessmen employing the chief workmen and construction workers. For this reason, it is expected that they will be charged a great deal of expenses such as increase in labor management services and laborers, the occurrence of an retirement grants, insurance fees, etc. Since the hold on power of field managers are getting weaker toward the construction workers, it is most likely to have loss in efficiency of production in the long term. Therefore purpose of this research is to analyze difficulties and the point at issues with which professional construction firms are undergoing after abolishing the construction participants system by investigating on the actual condition in the field management. For this research, we got a grip on the actual condition and analyzed the rise of a primary factor on reinforced concrete construction.

  • PDF

Improved Thermal, Structural and Electrical Properties of Elastic-Epoxy Blends System

  • Lee, Kyoung-Yong;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.230-235
    • /
    • 2004
  • In this paper, epoxy elasticity factors were investigated by TMA (Thermomechanical Analysis), DMTA (Dynamic Mechanical Thermal Analysis) and FESEM (Field Emission Scanning Electron Microscope) to improve toughness and reduce brittleness of existing epoxy resin. Dumbbell shaped specimens were made and tested at rates of 0, 20 and 35phr (part per hundred resins). TMA temperatures ranged from -2$0^{\circ}C$ to 20$0^{\circ}C$. Tg (glass transition temperature) of elastic epoxy was measured by thermal analysis. Also investigated were thermal expansion coefficient ($\alpha$), modulus and Tan$\delta$ (loss factor). And we analyzed structure through FESEM, could find elastic-factors of elastic epoxy that is not existing-epoxy. In addition, we measured permittivity and Tan$\delta$ for investigation of the electrical properties of elastic epoxy. Permittivity and Tan$\delta$ depend on elastomer composition. Namely, permittivity and Tan$\delta$ increase according to the elastomer contents. For experimental analysis results, 20phr was considered an excellent specimen.

Piezoelectric and Dielectric Characteristics of Low Loss Low Temperature Sintering PMN-PNN-PZT Ceramics with the amount of PNN Substitution (PNN 치환량에 따른 저손실 저온소결 PMN-PNN-PZT 세라믹스의 압전 및 유전특성)

  • Yoo, Ju-Hyun;Kim, Kook-Jin;Jeong, Yeong-Ho;Lee, Su-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.9
    • /
    • pp.766-770
    • /
    • 2007
  • In this study, in order to develop low temperature sintering ceramics for multilayer piezoelectric actuator, $0.07Pb(Mn_{1/3}Nb_{2/3})O_3-xPb(Ni_{1/3}Nb_{2/3})O_3-(0.93-x)Pb(Zr,Ti)O_3$ ceramics system were fabricated using $Li_2CO_3-Bi_2O_3-CuO$ sintering aids and the specimens were sintered at $930^{\circ}C$. Thereafter, their piezoelectric and dielectric characteristics were investigated according to the amount of PNN substitution. At 9 mol% PNN substitution, density, electromechanical coupling factor ($k_p$), dielectric constant, mechanical quality factor ($Q_m$) and piezoelectric constant ($d_{33}$) showed the optimum value of $7.86g/cm^3$, 0.60, 1640, 1323 and 387 pC/N, respectively. It is considered that these values are suitable for piezoelectric divece application such ad multilayer piezoelectric actuator and ultrasonic vibrator with pure Ag internal electrode.

Loss analysis for the novel half bridge inverter with load free-wheeling mode (부하 환류모드를 제공하는 새로운 반 브리지 인버터의 손실해석)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.216-219
    • /
    • 2003
  • The resonant inverter is widely used for induction heating, electronic ballast and supersonic motor driving circuit. In the meantime, control techniques of PWM, PFM etc.. are mainly applied to control the output power of the resonant inverter. But, in the case of using the half bridge resonant inverter, it is difficult to control the output power by PWM, because its main circuit does not provide the load free-wheeling mode. Therefore, PAM or PFM was usually applied to control output power of half bridge resonant inverter. However, PAM needs a variable DC voltage source, which makes the system structure more complex. On the other hand, in case of PFM, efficiency is declined by operation with poor power factor. This paper Proposed the novel half bridge resonant inverter which can provide the load free-wheeling mode. Also its analysis results for PWM operation with unity fundamental power factor are Presented and compared with other resonant inverters using PWM and PFM.

  • PDF

Design and Implementation of Tracking Filter for FH (주파수 도약용 추적 필터의 설계 및 제작)

  • Kang, Byung-Ook;Baek, Joo-Gi;Lee, Sang-Burm
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.4
    • /
    • pp.135-142
    • /
    • 2009
  • In this thesis, we designed and implemented a tracking filter which can be used for FH/2-FSK communication system in band of 40~60[MHz]. After measuring a performance of a tracking filter, an insertion loss was measured from 3.7 to 4.3 dB, depending upon a hopping center frequency. The 3 dB bandwidth of a tracking filter was specified 5.1 to 5.33% depend upon a hopping and 30/3 dB shape factor indication for interrupting property of a filter shows 6.828 to 6.98 satisfying a required specification. Also the attenuation $2{\times}f_0$, the characteristic parameter for interference degree, was specified 46~52dB, not satisfying a required specification.

  • PDF

Circuit Modelling and Eigenfrequency Analysis of a Poly-Si Based RF MEMS Switch Designed and Modelled for IEEE 802.11ad Protocol

  • Singh, Tejinder;Pashaie, Farzaneh
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.3
    • /
    • pp.129-136
    • /
    • 2014
  • This paper presents the equivalent circuit modelling and eigenfrequency analysis of a wideband robust capacitive radio frequency (RF) microelectromechanical system (MEMS) switch that was designed using Poly-Si and Au layer membrane for highly reliable switching operation. The circuit characterization includes the extraction of resistance, inductance, on and off state capacitance, and Q-factor. The first six eigenfrequencies are analyzed using a finite element modeler, and the equivalent modes are demonstrated. The switch is optimized for millimeter wave frequencies, which indicate excellent RF performance with isolation of more than 55 dB and a low insertion loss of 0.1 dB in the V-band. The designed switch actuates at 13.2 V. The R, L, C and Q-factor are simulated using Y-matrix data over a frequency sweep of 20-100 GHz. The proposed switch has various applications in satellite communication networks and can also be used for devices that will incorporate the upcoming IEEE Wi-Fi 802.11ad protocol.

Obstructive Sleep Apnea and Type 2 Diabetes (폐쇄성 수면무호흡 과 제2형 당뇨병)

  • Kang, Hyeon-Hui;Lee, Sang-Haak
    • Sleep Medicine and Psychophysiology
    • /
    • v.16 no.2
    • /
    • pp.61-64
    • /
    • 2009
  • Obstructive sleep apnea (OSA) has been definitively shown to be a risk factor for the development of cardiovascular disease and mortality. Recent reports have indicated that obstructive sleep apnea is associated with insulin resistance and impaired glucose metabolism, also have type 2 diabetes. The potential mechanisms leading to the development of type 2 diabetes in OSA patients are likely to be various. Reduced physical activity resulting from daytime somnolence, sympathetic nervous system activation, intermittent hypoxia, sleep fragmentation and sleep loss, dysregulation of the hypothalamic-pituitary axis, alteration in adipokine profiles, and activation of inflammatory pathways have been proposed. Based on the current evidence, clinicians should assess the risk of OSA in patients with type 2 diabetes and, conversely, consider that possibility of glucose intolerance in patients with OSA. Further large-scale and long-term follow-up studies in patient populations with selected by reliable but inexpensive diagnostic measures, controlled for potential confounder factor, are needed.

  • PDF

Effect of EGF against Oxygen Radical-Induced Neurotoxicity in Cultured Spinal Dorsal Root Ganglion Neurons of Mouse (산소자유기에 의해 저해된 배양 척수감각 신경절 세포에 대한 상피세포성장인자의 영향)

  • Park, Seung-Taeck;Kim, Hyung-Ryong;Chae, Han-Jung
    • YAKHAK HOEJI
    • /
    • v.41 no.1
    • /
    • pp.99-104
    • /
    • 1997
  • In order to elucidate the cytotoxic effect of oxygen radicals on cultured spinal dorsal root ganglion(DRG) neurons derived from mouse. the neurotoxic effect of oxygen radicals w as examined after cultured DRG neurons were exposed to xanthine oxidase(XO) and hypoxanthine(HX)-oxygen radical generating system. In addition. neuroprotective effect of epidermal growth factor(EGF) against oxidant-induced neurotoxicity was also evaluated in these cultures. The results were, as follows: 1. Lethal concentration 50(LC$_{50}$) was 35mU/ml XO and 0.1mM HX in cultured DRG neurons. 2. Oxygen radicals induced the morphological changes such as the decrease of cell number and loss of neurites in these cultures. 3. EGF increased the cell viability and neurofilament in neurons damaged by oxygen radicals. From above the results, it is suggested that oxygen radicals have a cytotoxic effect on cultured DRG neurons of neonatal mouse and selective neurotrophic factors such as EGF are, effective, in blocking the neurotoxicity induced by oxygen radicals in cultured spinal DRG neurons.

  • PDF

Channel Correlation Analysis using MIMO Channel Measurement Parameters at Domestic 700MHz band (국내 700 MHz 대역에서 MIMO 채널 측정 파라미터를 이용한 채널 상관도 분석)

  • Jung, Myoung-Won;Chong, Young-Jun;Pack, Jeong-Ki
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.1-7
    • /
    • 2013
  • In the next generation of mobile communication systems, high data rates and high capacity will be possible if multiple antennas are used at new frequencies. This paper presents the correlations between channel parameter path loss (PL), delay spread (DS), angular spread (AS) and K-factor established based on channel measurements. To avoid interference from Korean DTV broadcasting, we measured the channel characteristics in urban/rural/suburban areas on Jeju Island using a channel sounder and $4{\times}4$ antennas. The correlations between channel parameter show that the wireless channel characteristics can be determined and effective communication system design can be produced for use in similar environments.

A Study on PFC Buck-Boost AC-DC Converter by Soft Switching Method (소프트 스위칭형 PFC 승강압 AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Lee, Seung-Ho;Lee, Bong-Seob;Jung, Do-Young;Shim, Jae-Sun;Im, Jin-Geun
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.435-437
    • /
    • 2007
  • Authors propose a PFC(power factor correction) Buck-Boost AC-DC converter by soft switching method. The proposed converter for a discontinuous conduction mode eliminates the complicated control requirement and reduces the size of components. The input current waveform in the converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching.Therefore,the input power factor is nearly unity and the control algorithm is simple. To achieve high efficiency system, the proposed converter is constructed by using a partial resonant technique. The control switches using in the converter are operated with soft switching for a partial resonant. The control switches are operated without increasing their voltage and current stresses by the soft switching method. The result is that the switching loss is very low and the efficiency of converter is high.

  • PDF