• Title/Summary/Keyword: System IC

Search Result 1,156, Processing Time 0.035 seconds

An Adaptive Multi-Level Thresholding and Dynamic Matching Unit Selection for IC Package Marking Inspection (IC 패키지 마킹검사를 위한 적응적 다단계 이진화와 정합단위의 동적 선택)

  • Kim, Min-Ki
    • The KIPS Transactions:PartB
    • /
    • v.9B no.2
    • /
    • pp.245-254
    • /
    • 2002
  • IC package marking inspection system using machine vision locates and identifies the target elements from input image, and decides the quality of marking by comparing the extracted target elements with the standard patterns. This paper proposes an adaptive multi-level thresholding (AMLT) method which is suitable for a series of operations such as locating the target IC package, extracting the characters, and detecting the Pinl dimple. It also proposes a dynamic matching unit selection (DMUS) method which is robust to noises as well as effective to catch out the local marking errors. The main idea of the AMLT method is to restrict the inputs of Otsu's thresholding algorithm within a specified area and a partial range of gray values. Doing so, it can adapt to the specific domain. The DMUS method dynamically selects the matching unit according to the result of character extraction and layout analysis. Therefore, in spite of the various erroneous situation occurred in the process of character extraction and layout analysis, it can select minimal matching unit in any environment. In an experiment with 280 IC package images of eight types, the correct extracting rate of IC package and Pinl dimple was 100% and the correct decision rate of marking quality was 98.8%. This result shows that the proposed methods are effective to IC package marking inspection.

The Implementation of The Multi-Subject, Multi-Channel Optical Telemetry System for Physiological Signals

  • Park, Cha-Hun;Park, Jong-Dae;Seo, Hee-Don
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.448-454
    • /
    • 2000
  • This paper describes the implementation of a multi-subject, multi-channel optical telemetry system for the short range measurement of electrocardiograms (EKGs) a system which receives command signals and transmits physiological signals to the external system using LED (Light Emitting Diode) and PD (Photodiode). This system decreases the dependency of power supply voltage to the CMOS IC chips and a new enforced synchronization technique using infrared bi-directional communication has also been proposed. The telemetry IC with the size of $5.1{\times}5.1mm^2$ has the following functions: receiving of command signal, initialization of internal state of all functional blocks, decoding of subject selection signal, time division multiplexing of 4-channel modulated physiological signals, transmission of modulated signals to external system, and auto power down control.

  • PDF

Investigation of Buffer Traps in AlGaN/GaN Heterostructure Field-Effect Transistors Using a Simple Test Structure

  • Jang, Seung Yup;Shin, Jong-Hoon;Hwang, Eu Jin;Choi, Hyo-Seung;Jeong, Hun;Song, Sang-Hun;Kwon, Hyuck-In
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.478-483
    • /
    • 2014
  • We propose a new method which can extract the information about the electronic traps in the semi-insulating GaN buffer of AlGaN/GaN heterostructure field-effect transistors (HFETs) using a simple test structure. The proposed method has a merit in the easiness of fabricating the test structure. Moreover, the electric fields inside the test structure are very similar to those inside the actual transistor, so that we can extract the information of bulk traps which directly affect the current collapse behaviors of AlGaN/GaN HEFTs. By applying the proposed method to the GaN buffer structures with various unintentionally doped GaN channel thicknesses, we conclude that the incorporated carbon into the GaN back barrier layer is the dominant origin of the bulk trap which affects the current collapse behaviors of AlGaN/GaN HEFTs.

Studies on Cure Behaviors, Dielectric Characteristics and Mechanical Properties of DGEBA/Poly(ethylene terephthalate) Blends

  • Park, Soo-Jin
    • Macromolecular Research
    • /
    • v.17 no.8
    • /
    • pp.585-590
    • /
    • 2009
  • The cure behaviors, dielectric characteristics and fracture toughness of diglycidylether of bisphenol-A (DGEBA)/poly(ethylene terephthalate) (PET) blend system were investigated. The degree of conversion for the DGEBA/PET blend system was measured using Fourier transform infrared (FTIR) spectroscopy. The cure kinetics were investigated by measuring the cure activation energies ($E_a$) with dynamic differential scanning calorimetry (DSC). The dielectric characteristic was examined by dielectric analysis (DEA). The mechanical properties were investigated by measuring the critical stress intensity factor ($K_{IC}$), critical strain energy release rate ($G_{IC}$), and impact strength test. As a result, DGEBAIPET was successfully blended. The Ea of the blend system was increased with increasing PET content to a maximum at 10 phr PET. The dielectric constant was decreased with increasing PET content. The mechanical properties of the blend system were also superior to those of the neat DGEBA. These results were attributed to the increased cross-linking density of the blend system, resulting from the interaction between the epoxy group of DGEBA and the carboxyl group of PET.

A Study on the Integrated Communication Systems for a Remote Control of Radio Communication Equipments (무선통신장치의 원격제어를 위한 통합통신 시스템에 관한 연구)

  • 조학현;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.692-698
    • /
    • 2001
  • The radio communications by SSB and VHF transceivers are still used very efficiently in coast stations and military base stations. The communication system by the conventional SSB and VHF transceivers between a coast station and a terminal is an one-to-one system. In this dissertation, however, the conventional one-to-one system is expanded to one-to-multiple systems. Then, frequencies can be used effectively for distress, urgency, safety traffic, and military communications. An ICS has been proposed and added, in this dissertation, to the conventional SSB and VHF communication systems, which can realize one-to- several terminal communications. The line switching system by the ICS is to be remote-controlled by ASK modulated PTT signals and audio signals. An ICS can change a connection between terminal and transceiver through a circuit switching system at any time. For this purpose, the author has researched and developed a ASK transmission system, ICS system, control algorithm, multiprocessor system, and moni-toring system. As a conclusion, the developed line switching control systems and equipments can be used effectively for maritime communication, military communication, fishery communication, etc.

  • PDF

Determination of Trace-Level Perchlorate by IC-MS/MS and Distribution in the Han River (IC-MS/MS를 이용한 수중의 과염소산이온 분석방법 최적화 및 한강수계내 분포조사)

  • Kim, Hyun-Hee;Han, Ihn-Sup;Jeong, Gwan-Jo;Park, Hyeon;Han, Sun-Hee;Cho, Wan-Seon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.349-356
    • /
    • 2010
  • Ion chromatography (IC) coupled with conductivity detector (CD) is a common system for the determination of perchlorate in water samples. Although the IC method with CD has been widely used for the determination of trace level perchlorate ion in water, sensitivity decreases dramatically as the complexity of the matrices increases. Here we proposed the application of ion chromatography coupled with mass spectrometry (IC-MS/MS) to significantly improve selectivity of perchlorate. The mean recovery of the method was 104.4 ${\pm}$ 5.7% and the relative standard deviation (RSD%) was 1.9 ${\pm}$ 1.3%. The alculated method detection limit (MDL) was 0.0207 ${\pm}$ 0.0099 ${\mu}g/L$. The concentrations of perchlorate were minimum <0.1 ${\mu}g/L$ and maximum 18.3 ${\mu}g/L$ in source water (Namhan, Bukhan and Han River). Hongreung showed higher concentrations ($1^{st}$-14.3 ${\mu}g/L$, $2^{st}$-18.3 ${\mu}g/L$) than the other places. And the concentrations of perchlorate were 0.18~0.34 ${\mu}g/L$ in the samples taken from the six water treatment plants and six intake stations in Seoul.

The Study on the Radiation-Proof Video Camera system Remote Module of the Tube type (촬상관타입의 원격모듈화 내방사선 카메라시스템 연구)

  • Baek, Dong-Hyun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.6
    • /
    • pp.793-799
    • /
    • 2018
  • The CCD camera is easily deteriorated by radiation, and an integrated camera using an image pickup tube is used in a high radiation area. We implemented a radiation camera system which is divided into a camera head using radiation-resistant electronic components and a remote control using weak radiation-resistant electronic components such as TR, IC, etc. According to the experimental results, the first damage of the electronic parts was IC for horizontal and vertical sync generation, and it was confirmed that if the radiation of $2{\times}10^5{\sim}10^6rad$ is accumulated, the normal function is lost. In addition, the signal transmission cable for remoteization has added an input/output buffer circuit and reduced the closed loop area of the shield and the cable to eliminate signal loss correction and noise. Therefore, it is expected that the maintenance cost will be greatly reduced and practical because only the camera head part can be used instead of replacing the entire system.

Performance of Dual Polarized MIMO System using Six-Port Receiver for Cognitive Radio

  • Lee Sang-Yub;Yang Wan-Cheol;Lee Jeong-Suk;Kim Hak-Sun
    • Broadcasting and Media Magazine
    • /
    • v.11 no.1
    • /
    • pp.78-85
    • /
    • 2006
  • Cognitive radio is a paradigm for wireless communication in which either network of wireless node itself changes particular transmission or reception parameters to execute its tasks efficiently without interfering with the licensed users. This paper represents a performance of the cognitive radio technology on dual polarized MIMO system using six-port receiver. Six-port technology is well known direct conversion receiver. In this paper, a six-port phase discriminator based polarization signal separation is shown. That is, the SER(Symbol Error Rate) performance is improved using polarization separator and simple receiver architecture is proposed applying six-port receiver. The six-port technology has priority to adapt changeable frequency system and variable environments for cognitive radio. In general, dual polarized MIMO system has good capacity and quality using polarization separator [1].

Implementation of system security platform based on Cortex-M3 (Cortex-M3기반 System 보안 플랫폼 구현에 대한 연구)

  • Park, Jung-kil;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.317-320
    • /
    • 2016
  • In embedded system, if firmware code is opened by other company, must devise hardware copy prevention. That guard valuable product. Not used security IC, Suggested platform is source code open method that prevent core code and hardware copy. And that open firmware code for other company programmer. Suggest system security platform based on Corex-M3. that consist of IAP(In-application programing) and APP(Applicataion). IAP contain core code and security confirm code. APP is implement by other company developer using core function prototype.

  • PDF

A study of crystal growth and phase transition in $K_2Zn_{1-X}Co_XCl_4$ mixed crystal ($K_2Zn_{1-X}Co_XCl_4$ 결정 성장 및 상전이에 관한 연구)

  • 김성규;안호영;정세영
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.2
    • /
    • pp.278-285
    • /
    • 1998
  • It was known that the C-IC transition in the mixed crystal $(A_{1-x}A^'_x)_2ZnCl_4$ is smeared out with increasing x, which is attributed to the pinning effect of the doped A' ions. In this study, we introduce a new mixed crystal system $K_2Zn_{1-X}Co_XCl_4$, where doped Co ions do not destroy the orientation of the polarization in C phase and preserve the long range ordering of IC phase. We grew a series of mixed crystals $K_2Zn_{1-X}Co_XCl_4$ for x=0, 0.001, 0.005, 0.01, 0.05, 0.1, 0.3, 0.5, 0.7, 1 by the Czochralski method and investigated the real composition of the mixed crystals, structure and the change of the C-IC phase transition with increasing x by the thermal analysis.

  • PDF