• 제목/요약/키워드: Synchronizing Current

검색결과 25건 처리시간 0.032초

교류발전기 병렬운전시 과도현상 해석에 관한 연구 (A Study on the Transient Phenomenon Analysis at the instant of Parallel Running for A.C. Generators)

  • 오세진;김현수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권5호
    • /
    • pp.1065-1075
    • /
    • 2001
  • It is common knowledge amongst electrical and marine engineers that short-circuit in electrical system may cause large mechanical torque on generator and prime mover However, it is not so widely known that the faulty synchronizing of generators may cause even higher torques than that of short-circuit. In this study, the transient phenomena related to the parallel running of synchronous generators are analyzed and the exact computer simulation method is proposed. In result, maximum transient torque and current take place in case of $120^{\circ}$ voltage angle difference between Master and Slave and that may develop higher torque than the short-circuit according to a condition of synchronizing. When synchronizing in power system using only two generators higher torque and current occur Master, but using multimachine system those occur to Slave. The short-circuit of marine generator does not happen frequently but faulty synchronizing sometimes takes place, therefore, it is necessary for designers to consider these phenomena.

  • PDF

자동동기검출회로 성능진단에 관한 연구 (A Study of In-Depth Diagnosis Method for Automatic Synchronizing Circuits)

  • 박호철;천영식;장기준;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.582-584
    • /
    • 1999
  • Generator has synchronized with power Network after build-up output voltage. In order to prevent a current surge when synchronizing, the conditions such as identical no-load voltages identical no-load frequencies and identical phase positions must be met between generator voltage and network voltage. Hydro-Pump generators or Gas-turbine generators, Co-generation Generators that serve peak load of network are synchronized many times. So, Automatic Synchronizing Circuits are very important service. This report apply Diagnosis methods the Automatic Synchronizing Circuits(Device) by developing simulator.

  • PDF

컨버터가 내장된 교류발전기 병렬운전중의 헌팅을 균압선을 이용해 제거하는 방법에 관한 연구 (A Study on the Removing Method of Hunting by Equalizing Line during Parallel Running of alternator Equipped with converter)

  • 노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.352-359
    • /
    • 1999
  • This paper is a research for removing the alternators hunting which came about during the par-allel running. The four-pole six-phase alternator is equipped with the converter made out of twelve diodes to rectify all the waves. The hunting came about during the battery charging due to the hunting inducing point existed in r. p. m band 1575[rpm-1690[rpm] To remove the hunting inducing point We modified the four-pole six-phase alternator into the four-pole twevel-phase and increased the short-circuit ratio by decreasing the field coil pitch and increasing the field coil turns. But this method has two defects the first the alternator structure becomes complicating and the second the second the alternator equipped with the converter used in general purpose lately such as the car alternator can not be run in parallel wlthout modifying. To remove the defects the equalizing line was connected between the same phase of the alterna-tor to flow the synchronizing current which syncronize the phases of generator electromotive forces by which the alternator can be run in parallel without reference to the hunting inducing point and without modifying.

  • PDF

A Harmonic Circulation Current Reduction Method for Parallel Operation of UPS with a Three-Phase PWM Inverter

  • Kim Kyung-Hwan;Kim Wook-Dong;Hyun Dong-Suk
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.160-165
    • /
    • 2005
  • In a parallel operation of UPS, there are two types of circulating currents between UPS. One is the low order circulating current with a fundamental frequency caused by the amplitude and phase differences of UPS output voltages, and the other is the harmonic circulating current with PWM switching frequency caused by non-synchronized PWM waveforms among UPS. The elimination of the low order circulating current is essential for optimal load sharing in parallel operations of UPS, which can be accomplished by the phase and magnitude control at each UPS. The harmonic circulating current may cause troubles and deteriorate in performance of the controller for optimal load sharing in parallel operation of UPS. This paper presents a PWM synchronizing method to eliminate the harmonic circulation current in parallel operation of UPS. The effectiveness of the proposed scheme has been investigated and verified through experiments by a 50kVA UPS.

서보 모터의 피드백 전류와 위치신호를 이용한 서보건의 가압력 제어에 관한 연구 (The study of force control by using feedback current and encoder signal of the servo-motor on the servo-gun system)

  • 이종구;김태형;이세헌
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.63-65
    • /
    • 2005
  • Because of simple principal and low cost, resistance spot welding has been used a lot for joining the sheet metal in automotive manufacturing process. Welding current, welding time, and force are the most important variables in resistance spot wording. Air guns have hem still used widely. The requirement of synchronizing between robot and weld-gun has become bigger as the field has been automated. The number of servo-gun in the field is trending upward because there're advantages as like to synchronize with robot and to control the stroke path and force by programming on servo-gun system. But no cleared force control method is suggested on servo-gun system until now. In this study, we proved the feedback current of the servo-motor can be used to an excellent force measuring sensor and the force is controlled by the feedback current. And we also detected force lowering during welding cycle on the servo-gun system and solved by compensated force control.

  • PDF

디지털 제어를 이용한 알루미늄 아크 용접기의 기술현황 (Technology on Arc Welding Machine of Aluminum by Digital Control)

  • 이창제;김유찬;김종도
    • Journal of Welding and Joining
    • /
    • 제31권1호
    • /
    • pp.26-32
    • /
    • 2013
  • Recently, welding technology of nonferrous metals which were difficult to implement by arc welder has become available through digitalization of arc welding machine. Among them, the welding quality improvement of aluminum welding is very noticeable. These results increase the arc stability by controlling arc current and voltage waveform precisely, and control wire feed speed by synchronizing with arc current which the feed rate of filler wire is controlled by a precise motor control of servomotor and not by a simple constant speed feeding. Not only through the hardware digitalization of arc welding machine but also through advance of software of arc welding, it became possible to implement a certain level of welding quality by a simple operation. These led to CMT welding process implementation which requires low heat input than current arc welding and highly increased the applicability of the aluminum welding.

항공기 제조업에서 생산계획 동기화를 통한 데이터기반 구매조달 및 재고관리 방안 연구 (A Scheme of Data-driven Procurement and Inventory Management through Synchronizing Production Planning in Aircraft Manufacturing Industry)

  • 유경열;최홍석;정대율
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제30권1호
    • /
    • pp.151-177
    • /
    • 2021
  • Purpose This paper aims to improve management performance by effectively responding to production needs and reducing inventory through synchronizing production planning and procurement in the aviation industry. In this study, the differences in production planning and execution were first analyzed in terms of demand, supply, inventory, and process using the big data collected from a domestic aircraft manufacturers. This paper analyzed the problems in procurement and inventory management using legacy big data from ERP system in the company. Based on the analysis, we performed a simulation to derive an efficient procurement and inventory management plan. Through analysis and simulation of operational data, we were able to discover procurement and inventory policies to effectively respond to production needs. Design/methodology/approach This is an empirical study to analyze the cause of decrease in inventory turnover and increase in inventory cost due to dis-synchronize between production requirements and procurement. The actual operation data, a total of 21,306,611 transaction data which are 18 months data from January 2019 to June 2020, were extracted from the ERP system. All them are such as basic information on materials, material consumption and movement history, inventory/receipt/shipment status, and production orders. To perform data analysis, it went through three steps. At first, we identified the current states and problems of production process to grasp the situation of what happened, and secondly, analyzed the data to identify expected problems through cross-link analysis between transactions, and finally, defined what to do. Many analysis techniques such as correlation analysis, moving average analysis, and linear regression analysis were applied to predict the status of inventory. A simulation was performed to analyze the appropriate inventory level according to the control of fluctuations in the production planing. In the simulation, we tested four alternatives how to coordinate the synchronization between the procurement plan and the production plan. All the alternatives give us more plausible results than actual operation in the past. Findings Based on the big data extracted from the ERP system, the relationship between the level of delivery and the distribution of fluctuations was analyzed in terms of demand, supply, inventory, and process. As a result of analyzing the inventory turnover rate, the root cause of the inventory increase were identified. In addition, based on the data on delivery and receipt performance, it was possible to accurately analyze how much gap occurs between supply and demand, and to figure out how much this affects the inventory level. Moreover, we were able to obtain the more predictable and insightful results through simulation that organizational performance such as inventory cost and lead time can be improved by synchronizing the production planning and purchase procurement with supply and demand information. The results of big data analysis and simulation gave us more insights in production planning, procurement, and inventory management for smart manufacturing and performance improvement.

TCSC의 소신호 모형을 이용한 점호각 제어에 의한 저주파 진동 감쇠 효과 해석 및 제어 (Analysis and Control of Low Frequency Oscillation using TCSC Small Signal Model by Control of Firing Angles)

  • 김태현;서장철;박종근;문승일;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.120-124
    • /
    • 1995
  • TCSC can not only increase power flow but also damp low frequency oscillation by controlling firing angles of thyristors. But, a model considering voltage, current firing angles is not derived. This paper used a small signal model considirng these variables which was derived in paper [1]. TCSC model is combined with swing equation. Being related to rotor angles and firing angles of thyristors, current and synchronizing torque coefficient is reformulated. Because firing angles of thyristors can be controlled only twice within one period, swing equation is transformed to discrete time model. It is shown that low frequency oscillation can be damped by controlling firing angles in one machine infinite bus power system.

  • PDF

새로운 고효율 계통연계 1kW 연료전지용 PCS (A Noval High Efficiency Grid Connected 1kW PCS for Fuel Cell)

  • 김태진
    • 한국수소및신에너지학회논문집
    • /
    • 제19권5호
    • /
    • pp.417-422
    • /
    • 2008
  • In this paper, a novel DC/DC low-voltage high-current converter circuit is proposed to improve the efficiency of power converter used in the grid-connected fuel-cell generator system. We proposed a novel high efficiency grid-connected power conditioning system for RPG fuel cell. On the result of that, the loss of system was decreased rapidly by driving stack within the condition of maximum efficiency. The peak currents of the current-type inductor and the transformer's coil are reduced by synchronizing switching frequency of Buck-type converter is increased twice as the Push-Pull converter's switching frequency. The novel structure of DC/DC converter is able to realize ZVS-ZCS in fuel-cell system is proposed. The proposed switching component of Push-Pull converter has the ZVS and ZCS function by using the circuit of new passive clamp.

스텝 모터에 의한 X-Y 평면 구동 제어 시스템 개발 (DEVELOPMENT OF X-Y PLANE DRIVING CONTROL SYSTEM BY STEPPING MOTOR)

  • 이사영;김봉희;박성대;김홍철;김원철;홍일선;우천희;오봉환;이복구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2166-2168
    • /
    • 1998
  • A PWM inverter using power FET is developed to switch the excitation current of 5 phase hybrid stepping motor for the use of driving X, Y table. A micro processor based controller is also developed to control the excitation current switching of X, Y axis stepping motor as well as synchronizing operation of Z-axis servo motor. The developed driving control system is applied to the industrial embroidery sewing machine.

  • PDF