• 제목/요약/키워드: Switching valve

검색결과 79건 처리시간 0.026초

자동차 엔진용 2단 가변밸브 기구의 스위칭 시스템 동적 거동에 관한 연구 (A Study on the Dynamic Behavior of a 2-step Variable Valve Switching System for Automotive Engines)

  • 김동일;김도중
    • 한국자동차공학회논문집
    • /
    • 제22권6호
    • /
    • pp.39-48
    • /
    • 2014
  • Variable valve actuation system is one of the widely used techniques to improve the fuel efficiency and power of automotive engines. 2-step variable valve actuation systems are also paid attention for the application to direct acting type valve train systems. Besides its advantages in size, weight, relatively simple structure, ets, however, 2-step variable valve actuation system has inherent disadvantages in dynamic instability of switching system to alter discontinuous lift modes. In this study, both experimental and analytical studies are performed to understand the dynamic behavior of a switching mechanism of a 2-step variable valve actuation system, and present a design method to improve its dynamic instability.

유압브레이커의 수동 무단 타격력 제어기구 개발에 대한 연구 (A Study on Manually and Continuously Variable Impact Force Control Device Development for Hydraulic Breakers)

  • 강영기;장주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.46-53
    • /
    • 2020
  • In this paper, the development of a manually and continuously variable impact force control mechanism for hydraulic breakers was studied. Generally, a hydraulic breaker has one or two piston strokes. Hydraulic breakers, which have two strokes, have two valve-switching ports and make short and long piston strokes. The piston stroke valve controls the piston stroke by opening and closing a short stroke-switching port. The short piston stroke mode is used to break soft rock, concrete, or asphalt. This stroke control valve system is not popular for small hydraulic breakers mounted on 1 to 14-ton excavators. To preserve the carrier-like excavator, proper breaking force is needed, and it can be easily controlled by multiple piston stroke control valves. The easiest way to control these breakers is to use several switching ports and valves but they are not easy to install in small hydraulic breakers and are expensive. To use only one switching port and valve, a method can be used to change the open area of the switching port to delay valve switching. This method provides multiple piston strokes.

공진회로를 이용한 대용량 인버터 구성용 밸브 및 폴 시험설비에 관한 연구 (A Test System of Valve and Poles for Large Scale Inverter using Resonant Circuit)

  • 한영성;정정주
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.971-976
    • /
    • 2011
  • This paper proposes a test system for a valve and poles building blocks used for large scale inverters such as STATCOM, SSSC, UPFC and VSC HVDC. Power semiconductors in the valve are normally connected in series to withstand switching voltage much larger than the voltage rating of a single power semiconductor. Therefore, there is a need to verify if the dynamic voltage sharing during switching in a valve is satisfactory. In this paper, we propose a test system that provides the necessary test condition: voltage and current in the valve using resonant circuits. A test scheme for a single phase inverter consisting two poles is also proposed. The performance of the inverter pole has to be verified at the factory test, before the system is installed at the site to secure the reliability of the system. The proposed scheme makes it possible to confirm if the pole can withstand voltage and current switching condition and handle loss.

Operation Limit of Flow Control for a Bistable Fluidic Valve

  • Lee, Ji Ung;Hong, Ji-Seok;Sung, Hong-Gye
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.389-394
    • /
    • 2017
  • The limitation of flow control for a bistable fluidic valve has been investigated. The physical model of the fluidic valve includes two main flow outlets and two control flow inlets. The experiments were conducted with pressure regulators, mass flow meters, and piezo sensors to analyze flow switching characteristics of the fluidic valve. The experimental data such as pressure and mass flow rate of control flows and the switching time of the main flow was obtained with various operating conditions. The operation limit of the fluidic valve is identified, and a model equation for pre-estimating the minimum control pressure to switch the direction of the main flow has been proposed.

고속 온.오프 전자밸브를 사용한 유압실린더 힘 제어계의 응답성 개선 (Response Improvement in Hydraulic Cylinder Force Control System by Using a High Speed On-Off Electro-Magnetic Valve)

  • 이일영;권정호;박정환
    • 유공압시스템학회논문집
    • /
    • 제1권4호
    • /
    • pp.15-21
    • /
    • 2004
  • High speed on-off electro-magnetic valves have been used for pressure control or flow control in automotive or construction machine servomechanisms. These systems require quicker valve switching speed to improve control preciseness. The authors designed and manufactured an electric valve driver with quick response characteristics by using 3 power source type valve driver concept. In experiments by using a hydraulic system incorporating the new valve driver, the new driver shortened the switching lag time from 5 ms to 1.3 ms. And also the new driver showed excellent position tracking control performances.

  • PDF

Multilevel Magnetization Switching in a Dual Spin Valve Structure

  • Chun, B.S.;Jeong, J.S.
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.328-331
    • /
    • 2011
  • Here, we describe a dual spin valve structure with distinct switching fields for two pinned layers. A device with this structure has a staircase of three distinct magnetoresistive states. The multiple resistance states are achieved by controlling the exchange coupling between two ferromagnetic pinned layers and two adjacent anti-ferromagnetic pinning layers. The maximum magnetoresistance ratio is 7.9% for the current-perpendicular-to-plane and 7.2% for the current-in-plane geometries, with intermediate magnetoresistance ratios of 3.9% and 3.3%, respectively. The requirements for using this exchange-biased stack as a three-state memory device are also discussed.

Intelligent Switching Control of Pneumatic Cylinders by Learning Vector Quantization Neural Network

  • Ahn KyoungKwan;Lee ByungRyong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.529-539
    • /
    • 2005
  • The development of a fast, accurate, and inexpensive position-controlled pneumatic actuator that may be applied to various practical positioning applications with various external loads is described in this paper. A novel modified pulse-width modulation (MPWM) valve pulsing algorithm allows on/off solenoid valves to be used in place of costly servo valves. A comparison between the system response of the standard PWM technique and that of the modified PWM technique shows that the performance of the proposed technique was significantly increased. A state-feedback controller with position, velocity and acceleration feedback was successfully implemented as a continuous controller. A switching algorithm for control parameters using a learning vector quantization neural network (LVQNN) has newly proposed, which classifies the external load of the pneumatic actuator. The effectiveness of this proposed control algorithm with smooth switching control has been demonstrated through experiments with various external loads.

2차원 자기장에 의한 spin-valve 터널링 자기저항 소자의 자유층 반전 거동에 관한 연구 (Investigation on the Free Layer Switching behavior of a Spin-valve MTJ Device with 2 Dimensional Magnetic Field)

  • 이영우;김철기;김종오
    • 한국재료학회지
    • /
    • 제13권6호
    • /
    • pp.394-397
    • /
    • 2003
  • MTJ devices are fabricated using metal shadow masks and switching characteristics are investigated under 2 dimensional magnetic field. When the hard axis field is less than $\pm$ 16 Oe, switching behavior is similar to that based on the Stoner-Wohlfarth model. As the hard axis field is larger than $\pm$ 16 Oe, deviation from the expectation by Stoner-Wohlfarth model is observed. These phenomena are induced by the generation of multi-domain and inhomogeneous magnetization reversal.

HVDC 컨버터의 Thyristor Valve 시험을 위한 새로운 합성시험회로 (A New Synthetic Test Circuit for Testing Thyristor Valve in HVDC Converter)

  • 김경태;한병문;정재헌;노의철;정용호;백승택
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.191-197
    • /
    • 2012
  • This paper proposes a new synthetic test circuit (STC) to confirm the switching operation of thyristor valve in HVDC converter. The proposed STC uses a 6-pulse thyristor converter with 2-phase chopper as a high-current source to provide turn-on current to the test valve. The operation of proposed STC was verified through theoretical analysis and computer simulations. Based on computer simulations, a hardware scaled model was built and tested to confirm the feasibility of implementing a real-size test facility. The proposed system has an advantage of simple structure and operation over the existing system.