Bioenergy is generally considered to be one of the options for pursuing carbon neutrality. However, for a period of time, combustion of harvested plant biomass inevitably causes more carbon dioxide in the atmosphere than combustion of fossil fuels. This paper proposes a method that predicts and minimizes the total amount and payback period of this carbon debt. As a case study, a carbon cycle impact assessment was performed for immediate switching of the currently used fossil fuels to biomass. This work points out a fundamental vulnerability in the concept of carbon neutrality. As an action plan for the sustainability of bioenergy, formulas for afforestation proportional to the decrease in the forest area and surplus harvest proportional to the increase in the forest mass are proposed. The results of optimization indicate that the carbon debt payback period is about 70 years, and the carbon dioxide in the atmosphere increases by more than 50% at a maximum and 3% at a steady state. These are theoretically predicted best results, which are expected to be worse in reality. Therefore, biomass is not truly carbon neutral, and it is inappropriate as an energy source alternative to fossil fuels. The method proposed in this work is expected to be able to contribute to the approach to carbon neutrality by minimizing present and future carbon debt of the bioenergy that is already in use.
This paper proposes the DC-link voltage design method of Type 4 wind turbine that minimizes power loss and satisfies the High Voltage Ride Through(HVRT) function requirements of the transmission system operator. The Type 4 wind turbine used for large-capacity offshore wind turbine consists of the Back-to-Back converter in which the converter linked to the power grid and the inverter linked to the wind turbine share the DC-link. When the grid high voltage fault occurs in the Type 4 wind turbine, if the DC-link voltage is insufficient compared to the fault voltage level, the current controller of the grid-side converter can't operate smoothly due to over modulation. Therefore, to satisfy the HVRT function, the DC-link voltage should be designed based on the voltage level of high voltage fault. However, steady-state switching losses increase further as the DC-link voltage increases. Therefore, the considerations should be included for the loss to be increased when the DC-link voltage is designed significantly. In this paper, the design method for the DC-link voltage considered the fault voltage level and the loss is explained, and the validity of the proposed design method is verified through the HVRT function simulation based on the PSCAD model of the 2MVA Type 4 wind turbine.
The Journal of Korean Institute of Communications and Information Sciences
/
v.25
no.8A
/
pp.1160-1168
/
2000
This paper presents a real-time integrated traffic management (RITM) scheme that can effectively manage variable bit rate (VBR) and available bit rate (ABR) traffics having unpredictable characteristics in asynchronous transfer mode (ATM) networks. An unique feature of this scheme is that it has a special ATM cell control block which makes it possible to monitor bursty traffics in real-time so that the delay incurred to measure cell arrival rate is minimized. Additionally, the proposed scheme intends to dynamically reassign the leftover network resources to VBR/ABR connections without any deterioration in quality of service (QoS) of the existing connections. The RITM scheme has been verified to reliably monitor incoming traffics and to efficiently manage network resources by computer simulations. The capability of managing the incoming ATM traffics in real-time helps determine an optimal acceptable number of user connections for a given network condition. We can use this value as a threshold to protect the network from being congested and to find out a cost-effective buffer design method.
Journal of the Institute of Electronics Engineers of Korea TC
/
v.46
no.1
/
pp.10-23
/
2009
In this paper we propose a novel mobile terminal software architecture supporting energy efficient handover operation in heterogeneous networks. Since the legacy proposals for L3 handover are mostly dependent on IETF Mobile IP which has some problems in movement detection mechanism and no considerations on nested heterogeneous network environment as a result they make serious overload on networks and terminals by performing unnecessary handover in such network environments. The proposed architecture has terminal-oriented network selection and switching architecture where a mobile terminal periodically monitors network status and selects the optimum network, and reduces energy consumption by making L3 handover of Mobile IP to the finally selected network. The network selection method first picks up some candidate networks by considering a terminal speed and power consumption estimation, and determines the final target handover network among the candidates after evaluating multiple factors including QoS required by a terminal, network status, user preference and terminal battery status. Finally we verify the functionality and performance of the energy efficient vertical handover architecture by means of adopting it into a real mobile terminal.
This study was conducted to provide a vitamin $B_{12}$ database for the representative Korean food items and to assess the dietary intake assessment of vitamin $B_{12}$ for Koreans. The vitamin $B_{12}$ content of 106 foods had been determined by high performance liquid chromatography (HPLC) using column switching method. Rich sources of vitamin $B_{12}$ were meats, milk, and egg ($0.3-3.4\;{\mu}g/100g$). Vegetables and fruits contained vitamin $B_{12}$ below limit of detection (LOD). The major food sources for vitamin $B_{12}$ intake were milk (72.0%), meats (22.3%), egg (3.6%), and fishes & shellfishes (2.1%). Mean vitamin $B_{12}$ intake of Koreans was $3.16\;{\mu}g$/person/day. The proportion of population with intake below estimate average requirement (EAR) and above recommended intake (RI) of vitamin $B_{12}$ was 60.7 and 36.5%, respectively. The vitamin $B_{12}$ intake level of young children with 1-2 years which was 834.6% of RI while the intake level of the older adults 50 years and older was only 70.0% of RI. Also, there were regional differences between urban and rural area. The population with intake below RI was larger than that with intake above RI in Korea.
Journal of the Korean Institute of Electrical and Electronic Material Engineers
/
v.28
no.5
/
pp.291-294
/
2015
Recently, ZnO based oxide TFTs used in the flexible and transparent display devices are widely studied. To apply to OLED display switching devices, electrical performance and stability are important issues. In this study, to improve these electrical properties, we fabricated TFTs having Al doped Zinc Oxide (AZO) layer inserted between the gate insulator and ZnO layer. The AZO and ZnO layers are deposited by Atomic layer deposition (ALD) method. I-V transfer characteristics and stability of the suggested devices are investigated under the positive gate bias condition while the channel defects are also analyzed by the photoluminescence spectrum. The TFTs with AZO layer show lower threshold voltage ($V_{th}$) and superior sub-threshold slop. In the case of $V_{th}$ shift after positive gate bias stress, the stability is also better than that of ZnO channel TFTs. This improvement is thought to be caused by the reduced defect density in AZO/ZnO stack devices, which can be confirmed by the photoluminescence spectrum analysis results where the defect related deep level emission of AZO is lower than that of ZnO layer.
Journal of the Institute of Electronics Engineers of Korea SD
/
v.47
no.6
/
pp.35-42
/
2010
This paper describes a 10 bit 80MHz CMOS D/A converter for wireless communication system. The proposed circuit in the paper is implemented with a $0.18{\mu}m$ CMOS n-well 1-poly 6-metal process. The architecture of the circuit consists of the 4bit LSB with binary decoder, and both the 3bit ULSB and the 3bit MSB with the thermometer decoder. The measurement results demonstrates SFDR of 60.42dBc at sampling frequency 80MHz, input frequency 1MHz and ENOB of 8.75bit. INL and DNL have been measured to be ${\pm}$0.38LSB and ${\pm}$0.32LSB and glitch energy is measured to be 4.6$pV{\cdot}s$. Total power dissipation is 48mW at 80MHz(maximum sampling frequency) with a single power supply of 1.8V.
Journal of the Institute of Electronics and Information Engineers
/
v.49
no.9
/
pp.215-224
/
2012
Using password on system is easy to build and shorten the access time to authorize user, which is high in use for vary system that requires users' authorization. Many input device are able to perform the password system easily, such as PC, smart-phone, tablet PC, etc. Beside the high usability of password, physical attack occurs when user put their password on the device, known as Shoulder Surfing attack. It used to be formed in numbers, characters or mix of different kinds, but new kind of password arose. Exploiting image or making scenarios are those kinds which are able to reflect users' intentions. Not many estimation exists for new password, so there's need to be standard for those new password for highlighting usability and accessability. In this paper, we propose password system with simple image and switching key-board to test statistical method to estimate usability on the password.
Objective: This study was performed to assess our clinical experience with single-port access (SPA) laparoscopic cystectomy and myomectomy and the surgical outcomes of those procedures at our institution. Methods: The authors evaluated the surgical outcomes of SPA laparoscopic cystectomy in 293 patients and SPA laparoscopic myomectomy in 246 patients. The surgical outcomes comprised operation time, the amount of blood loss during the operation, the change in hemoglobin (before and after the operation), the change in hematocrit (before and after the operation), switching to the multi-port access method, complications, transfusions, and the duration of the postoperative hospital stay. Results: The Pearson correlation coefficient and the Spearman correlation coefficient between the operation time and the amount of blood loss were 0.312 and 0.321 for SPA laparoscopic cystectomy, respectively, and 0.706 and 0.674 for SPA laparoscopic myomectomy, respectively. The drops in hemoglobin and hematocrit were $1.33{\pm}0.78g/dL$ and $4.14%{\pm}2.45%$, respectively, in SPA laparoscopic cystectomy, while the corresponding figures were $1.34{\pm}1.13g/dL$ and $4.17%{\pm}3.24%$ in SPA laparoscopic myomectomy, respectively. Conclusion: This study reported the surgical outcomes of SPA laparoscopic cystectomy and myomectomy and compared them to previously published findings on traditional laparoscopic cystectomy and myomectomy. No significant differences were found in the surgical outcomes between SPA and traditional laparoscopic cystectomy and myomectomy.
Recently, as HTTP-based video streaming traffic continues to increase, Dynamic Adaptive Streaming over HTTP(DASH), which is one of the HTTP-based adaptive streaming(HAS) technologies, is receiving attention. Accordingly, many video quality control techniques have been proposed to provide a high quality of experience(QoE) to clients in a DASH environment. In this paper, we propose a new quality control method using ANFIS(Adaptive Network based Fuzzy Inference System) which is one of the neuro-fuzzy system structure. By using ANFIS, the proposed scheme can find fuzzy parameters that selects the appropriate segment bitrate for clients. Also, considering the characteristic of VBR video, the next segment download time can be more accurately predicted using the actual size of the segment. And, by using this, it adjusts video quality appropriately in the time-varying network. In the simulation using NS-3, we show that the proposed scheme shows higher average segment bitrate and lower number of bitrate-switching than the existing methods and provides improved QoE to the clients.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.